🔬 FFT Spectrum Analyzer – Fiche produit
Famille Analyseurs FFT multivoies
Canaux 2 à 32 (jusqu'à 1 000 en cascade)
Dynamique > 140 dB
Résolution A/D 24 bits
Plage fréquence 0,8 Hz – 100 kHz
Logiciel NVGate
Interface PC Ethernet LAN (RJ45)
OS supportés Windows 7 / 10 / 11
Hotline +33.4.76.90.52.40
E-mail support customer.care@oros.com

La gamme FFT Spectrum Analyzer Multipurpose d'OROS est une série d'analyseurs FFT PC-based haute performance dédiés à la mesure acoustique et vibratoire en milieu industriel et de R&D. Offrant une capacité d'analyse en temps réel 16 fois supérieure aux analyseurs conventionnels, ces instruments couvrent de 2 à 32 canaux simultanés (jusqu'à 1 000 canaux en cascade) avec une dynamique supérieure à 140 dB et une résolution de 24 bits.

Conçus pour les ingénieurs en NVH (Noise, Vibration, Harshness), analyse modale, suivi d'ordre, et mesure d'intensité sonore, ils s'appuient sur le logiciel NVGate pour l'acquisition, l'analyse et le reporting.

📦 Modèles disponibles

La famille se décline en cinq modèles adaptés à chaque contexte de mesure, du terrain léger à l'acquisition lourde multi-capteurs.

Comparatif des modèles FFT Spectrum Analyzer OROS
Modèle Canaux Poids Autonomie batterie Fréq. max analyse Enreg. autonome Cascade
O4 2 – 4 0,5 kg Batterie PC 100 kHz
OR10 8 0,8 kg 4 heures 40 kHz
OR35 6 – 10 2,8 kg 3 heures 40 kHz
TW OR36 4 – 16 5,2 kg 2 heures 40 kHz
TW OR38 8 – 32 8,2 kg 2 heures 40 kHz

Template:Note

⚙️ Spécifications techniques

Entrées analogiques

Paramètre Valeur
Connecteurs BNC
Couplage AC / DC / ICP (compatible IEPE)
Plage de tension ±100 mV à ±40 V (sélectionnable)
Convertisseur A/D 24 bits
Dynamique > 140 dB
Précision de phase ±0,02° à 20 kHz

Analyse fréquentielle

Paramètre Valeur
Plage de fréquence 0,8 Hz – 100 kHz (O4) / 0,8 Hz – 40 kHz (autres)
Fréquences d'échantillonnage 2,048 kHz à 102,4 kHz
Taille de bloc FFT 256 à 16 384 points
Recouvrement (Overlap) 0 % à 99,99 %
Fenêtres disponibles Flat Top, Hanning, Hamming, Kaiser, Rectangulaire

Sorties analogiques

Paramètre Valeur
Nombre de sorties 1 à 2 canaux (selon modèle)
Convertisseur D/A 24 bits
Plage de sortie ±10 V
Formes d'onde générées Sinus, Balayage (sweep), Chirp, Multi-sinus, Bruit aléatoire

Configuration PC recommandée

Paramètre Valeur
Processeur Quad-core (recommandé)
RAM 6 Go minimum
Système d'exploitation Windows 7 / 10 / 11
Interface réseau Ethernet LAN (RJ45)

💻 Logiciel NVGate

Tous les analyseurs FFT OROS fonctionnent avec le logiciel NVGate, une plateforme unifiée pour l'acquisition, l'analyse temps réel et le post-traitement des données acoustiques et vibratoires.

Interface utilisateur

  • Menu **Ribbon** (ruban) similaire à Microsoft Office pour une prise en main rapide
  • Jusqu'à **16 layouts** configurables, chacun supportant **jusqu'à 32 fenêtres** (512 fenêtres au total)
  • Glisser-déposer pour la comparaison de données
  • Recherche par métadonnées pour retrouver rapidement des mesures
  • Génération de rapport **en un clic** (Word, PDF)
  • Traitement batch pour automatiser les campagnes de mesure

Fonctions d'analyse temps réel

Fonction Description Module
Analyse FFT Spectre fréquentiel, densité spectrale de puissance (DSP) Standard
Waterfall (cascade 3D) Évolution du spectre dans le temps en 3D Standard
Analyse octave 1/1, 1/3, 1/12, 1/24 d'octave ORNV-OCT
Suivi d'ordre Jusqu'à 1 200 000 RPM ORNV-ORD
Analyse modale Test au marteau d'impact, FRF Standard
Intensité sonore Mesure de la puissance acoustique rayonnée Standard
Torsion rotationnelle Analyse IVC (Instantaneous Velocity Change) ORNV-IVC
Diagnostic rotation Détection défauts roulements/engrenages ORNV-FFTDiag
Analyse temporelle Corrélation, kurtosis, cepstrum ORNV-TDA
Sonomètre multi-voies LAeq, LAF, LAFmax, percentiles ORNV-OVA

Tests automatiques

  • Critères de réussite/échec (**Pass/Fail**) configurables par l'utilisateur
  • Masques fréquentiels (enveloppes de tolérance)
  • Export automatique des résultats vers bases de données

🔌 Options et modules

XPODS – Conditionneurs de capteurs

Disponibles sur OR35, TW OR36 et TW OR38 :

  • **Conditionneur jauge de déformation** (pont de Wheatstone)
  • **Amplificateur thermocouple** : types J, K, T, N, E

Module CAN-bus

Disponible sur OR10, TW OR35, TW OR36 et TW OR38 :

  • Suivi de vitesse de rotation **sans tachymètre** physique
  • Idéal pour les essais moteur en contexte automobile

Enregistrement autonome (Stand-alone)

Disponible sur OR35, TW OR36 et TW OR38 :

  • Fonctionnement **sans PC** sur le terrain
  • Configurations de mesure prédéfinies chargées à l'avance
  • Stockage SSD intégré : **64 à 512 Go**

Cascade synchrone

Disponible sur TW OR35, TW OR36 et TW OR38 :

  • Connexion de plusieurs analyseurs via câble LAN standard
  • Jusqu'à **1 000 canaux simultanés** synchronisés
  • Précision de phase inter-unité : **0,2° à 20 kHz**

🏭 Cas d'usage typiques

Secteur Application Modèle recommandé
🚗 Automobile NVH : mesure bruit/vibration véhicule, analyse passage de vitesse TW OR36 / TW OR38
✈️ Aéronautique Mesures en vol hélicoptère, analyse de structures TW OR38 (cascade)
🌬️ Énergie éolienne Surveillance vibratoire turbines, suivi d'ordre multiplicateur TW OR36 / TW OR38
🏗️ Machines-outils Contrôle qualité vibratoire, détection de défauts OR10 / OR35
🔬 R&D / Labo Analyse modale, caractérisation matériaux, FRF O4 / OR10 / OR35
🏭 Industrie générale Diagnostic roulements, maintenance prédictive OR10 / OR35
🚢 Naval Mesures structure, analyse cavitation hélices TW OR38 (cascade)

❓ Questions fréquentes (FAQ)

Peut-on utiliser le OR10 ou le OR35 sans ordinateur ?
Le OR10 nécessite un PC pour fonctionner. Le OR35, le TW OR36 et le TW OR38 disposent d'un mode enregistrement autonome permettant de capturer des données sans PC grâce à leur SSD intégré.
Quelle est la dynamique de mesure réelle ?
La dynamique dépasse 140 dB grâce au convertisseur A/D 24 bits. La précision de phase est de ±0,02° à 20 kHz, ce qui garantit une cohérence entre canaux pour l'analyse modale.
Comment synchroniser plusieurs analyseurs ?
Les modèles TW (OR35, OR36, OR38) supportent la cascade synchrone via câble LAN standard. La synchronisation est automatique et permet d'atteindre jusqu'à 1 000 canaux avec une précision de phase inter-unité de 0,2° à 20 kHz.
Quels capteurs sont compatibles ?
Les entrées BNC supportent accéléromètres (ICP/IEPE), microphones, jauges de déformation (via XPOD), thermocouples (J, K, T, N, E via XPOD). Le couplage AC/DC/ICP est sélectionnable par canal.
NVGate fonctionne-t-il sous Windows 11 ?
Oui, NVGate est compatible Windows 7, 10 et 11 (64 bits recommandé). La configuration minimale est un processeur quad-core avec 6 Go de RAM.
Quelle est la durée de garantie et les options de maintenance ?
OROS propose des contrats Premium de 1 à 4 ans avec une garantie de retour réparé sous 4 jours ouvrés. Des centres de maintenance accrédités sont présents en Europe, Asie, Amérique du Nord et Moyen-Orient.
Peut-on utiliser l'analyseur pour faire du contrôle qualité automatisé ?
Oui, NVGate intègre une fonction Pass/Fail avec masques fréquentiels configurables et export automatique des résultats. Le module batch processing permet d'automatiser les campagnes complètes.

🌍 Support et services

OROS s'appuie sur un réseau mondial de filiales, bureaux, revendeurs et centres de maintenance qualifiés.

Couverture géographique

  • 🇫🇷 France (siège – Meylan, Grenoble)
  • 🇩🇪 Allemagne · 🇬🇧 Royaume-Uni · 🇮🇹 Italie
  • 🇨🇳 Chine · 🇯🇵 Japon · 🇰🇷 Corée du Sud · 🇮🇳 Inde
  • 🇺🇸 États-Unis · 🇸🇦 Arabie Saoudite

Contrats de maintenance

Service Détail
Contrat Premium 1 à 4 ans, retour réparé sous 4 jours ouvrés
Hotline technique +33.4.76.90.52.40
Support e-mail customer.care@oros.com
Formations annuelles Cours NVGate et mesures acoustiques/vibratoires
Centres de calibration Accrédités ISO dans plusieurs pays

🔗 Voir aussi

Catégorie:Analyseurs FFT Catégorie:Mesure acoustique Catégorie:Mesure vibratoire Catégorie:NVH Catégorie:NVGate Catégorie:Matériel OROS



Analyzer acoustic vibration multichannel
FFT analyzers

The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.

We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.

In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB. These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.


Schedule a demo Get a quotation Contact support



Main Features

  • From 2-32 channels
  • Synchronous measurements up to 1000ch is possible by combining multiple analyzers (*)
  • Compact and lightweight (4ch model 1.5kg, 10ch model 3.0kg)
  • Achieves high-speed communication with a PC through an ethernet LAN interface
  • Equipped with an output channel as a standard
  • Built-in internal battery as a standard
  • Record, Fast Fourier Transform analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
  • Realtime measurements and post-analysis can be performed with the same software platform (NVGate)
  • In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS (**)
  • CAN-bus module compatible (***)
  • Recording is possible with analyzer in standalone mode or in conjunction with a PC (****)


(*) Synchronous measurements that combine multiple analyzers is possible only for TW OR35 / TW OR36 / TW OR38.

(**) The strain / temperature module(XPOD) can be installed only on TW OR35 / TW OR36 / TW OR38.

(***) CAN-bus module can be installed only on OR10/ TW OR35 / TW OR36 / TW OR38.

(****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38.

Introducing the hardware

OROS instrument analyzer for noise and vibration

Small and lightweight

OR10-8ch model: 0.8kg

O4: 4ch model: 0.5kg

OR35 TW: 10ch model: 3.0kg

OR36 TW: 16ch model: 5.2kg

OR38 TW: 32ch model: 8.2kg





Ethernet LAN interface

Back of FFT analyzer : ethernet connection for PC

Achieves high-speed communication with a PC through an ethernet LAN interface





Built-in battery

OR10/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.

OR10 can be operated by battery for 4hours

OR35 can be operated by battery for 3 hours.

TW OR36 / TW OR38 can be operated by battery for 2 hours.

04 operate with battery PC.

External battery

External battery on spetrum analyzer

We provide a compact and lightweight external battery that can be installed on all models.

Can be used for up to 8 hours with one external battery.

Can be stored in a "PC integrated carrying case".





Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers

(TW OR35 / TW OR36 / TW OR38 only)

High-precision synchronous measurements (0.2 ° @ 20kHz) are possible by simply connecting each analyzer using a general-purpose LAN cable. Function measurements can be taken with the hammer connected to the third unit in the chain and the accelerometers connected to each unit. Tracking analysis can be completed with the accelerometers connected to each unit while using a tachometer connected to the second unit in the chain.

cascade mode

Measure From Sound / Vibration and Strain Gauge / Temperature

(OR35 / TW OR36 / TW OR38 only)

Temperature and straing conditionner

By mounting a strain gauge conditioner and thermocouple conditioner on the Oros FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.

Thermocouple amplifier: Supports types J, K, T, N, E (with temperature compensation)



CAN-bus Module Available

Can bus to add on OROS instrument

(OR10/ TW OR35 / TW OR36 / TW OR38 only)

By using the CAN-bus module, tracking analysis can be performed using information such as the engine speed flowing from the CAN-bus. By using this function, tracking analysis can be performed without using a tachometer.

Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode

(OR35 / TW OR36 / TW OR38 only)

Vibration time signal Measurement without PC

The FFT analyzer is equipped with a record-only button. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.






In addition, the back of the Fast Fourier Transform Spectrum Analyzer Multipurpose is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors.

all the plug available on the backside of instrment


Software Introduction

  • Easy-to-use interface
  • Real-time measurement / post-analysis can be performed with the same software platform (NVGate)
  • One-click report creation function

Start the Measurement Quickly and Easily

You can start measuring immediately by using the quick function provided in the OROS FFT analyzer mult function. This is completed by defining the number of input channels in the channel field and the measurement/analysis content in the show results area.


The Oros series FFT spectrum analyzer multifunction uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.

NVgate ribbon technology

One-click Setting Function

With the Oros series multi-purpose FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below.


Parameters easy to change

Control Panel

In addition, the OROS FFT spectrum analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the control panel. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.

Control easily the software

Various filters can be applied to recorded signals & FFT analysis results

Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a filter, it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components.

Filter analyzer

Extract arbitrary order components from the color spectrum graph in real time

Any order component can be extracted in real time from the color spectrum graph.

order extraction on vibration software

Easy-to-read Layout

The area for arranging windows is called a layout. The OROS multi function FFT analyzer can create up to 16 layouts per project. You can easily arrange your windows by using the layout function. And your windows will open the same way each time.

It is possible to display up to 32 screens in one layout.

Up to 512 windows (= 16 x 32) can be displayed.


Layout utilization example:


Layout 1: Record waveform, FFT analysis result, order ratio analysis result displayed

Recorder and FFT together


Layout 2: Display 3D frequency analysis results and 3D order ratio analysis results

NVGate software on line measurement



Layout 3: Display 3D octave analyzer analysis results

Acoustic measurement with octave

Easy operation <Graph layout selection button>

You can easily arrange windows just by selecting the grid menu.

Grid icone


Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.

export your data


Data measured at different times can be overwritten by dragging which allows for easily comparing measurement data.

Software NVGate

One-click report creation function

Simply click the report button located on the ribbon interface to create a report file containing the current measurement results.

report all windows

• The content of the report is customizable. Customize it to the format that best suits your needs.

Post analysis vibration software

Measurement data search function

cloud vibration data

Various information (meta-data) can be added when saving measurement data. You then can search for measurement data and projects based on the added information.

Filter:

  • Project name
  • Measurement date and time
  • Measurement conditions
  • Measurement target
  • Measurement site
  • User

Acoustic and vibration search function

Fail judgment function as standard

The pass / fail feature of NVGate can be performed automatically after setting the desired bounds.

In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.

Failed pass test on resonnance frequency test

Automate post-analysis processing

The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours.


Offline measurement

specification

Main specifications

O4 OR35 OR36 OR38
Dynamical Input channel
Number of analysis channels 2, 4 6, 10
(Select Analysis or tachometer on 2 channels)
4, 8, 12, 16 8, 16, 24, 32
Terminal shape BNC
Input coupling and sensor support Compatible with AC, DC / ICP (sensor with built-in amplifier) ​​and TEDS
Cutoff frequency - 3dB at AC cutoff frequency 0.35Hz
Input voltage range +/- 100mV to +/- 40V (auto range function)
Maximum voltage 60V
Anti-Aliasing filter 400dB / OCT
Input impedance 1MΩ <100pF
A / D converter 24-bit
Dynamic range >140dB
Channels-to-channels phase accuracy ± 0.02 ° (10V, 20kHz range)
Input filter Acoustic A, C, Z, low pass, high pass, band pass, integrator, differentiator, time axis integration function
Sampling frequency of the signal Select from 13 ranges between 102.4kHz and 2.048kHz.
Tachometer channel (Ext synch channels)
Number of input channels 2 channels 2 channels (up to 6 channels as an option)
Sampling frequency 6.4MHz (counter method)
Voltage range +/- 300mV 40V
DC input
number of input channels none Analysis channel can be switched and used
Voltage range none 22 bits, ± 40V, offset DC 100μV or less
Samplingfrequency none 15Hz or 12.5Hz
Calibration function
Calibration method Automatic sensitivity calculation by numerical input or reference signal (for position and standard vibration oscillatory meter)
How to use at the time of measurement Select by registered sensor name such as model name and machine number
Trigger function
Trigger type Edge, period, △ RPM, △ level, manual, multi (A or B, A and B, A after B)
Trigger delay Pre- and post-trigger functions
Trigger signal Select from any input channel
Record function
Sampling frequency 13 ranges from 102.4kHz to 2.048kHz possible to select 2 types of range together
A / D converter resolution 24-bit or 16-bit
Hard drive size PC hard drive 64 GB SSD 128 GB removable SSD hard drive (256GB or 512 GB optional)
FFT analysis performance
Analysis frequency range 0.8Hz-100kHz 0.8Hz-40kHz
FFT block size 256, 512, 1024, 2048, 4096, 8192, 1638
Number of analysis lines 101, 201, 401, 801, 1601, 3201, 6401
Zoom analysis 2 to 128 times (all channels at the same time)
Overlap setting 0-99.99%
Window function Flat Top, Hanning, Humming, Kaiser Vessel, Rectangular, Force / Response
Average mode Time, frequency, fdsa / linear, exponential, peak hold
Analysis / display function
Time series Real-time waveform, record waveform, DC, Max, Min, RMS
FFT analysis Linear power spectrum, average spectrum, PSD, cross spectrum,

transfer function (H1, H2), copying function

Display color Display color: Arbitrary specification of trace, cursor, background, and grid display colors
Options:
Time domain analysis (ORNV-TDA)
Analysis items Monitor display for arbitrary time (msec to day), effective value for arbitrary section, Min, Max, Peak,

Peak / Peak, RMS, DC, crest factor, Skew, Kurtosis

1/n octave analysis (ORNV-OCT)
method Digital filter operation on time domain
Analysis band 1/1, 1/3, 1/12, 1/24 octave (IEC1260: 1995 Class 1, ANSI S1.11-1986)
Analysis frequency Simultaneous analysis of all channels at 20kHz is possible (DSP option may be required)
Average Fast, Slow, lmpulse, LEQ, constantBT, linear repeat,exponential
Multi-sound level meter [ORNV-OVA]
Operation method Time series signal digital operation
Acoustic weithing Linear, A, C
Measurement Leq, Fast, Slow, lmpulse, average, Peak, Max, Min
Average Fast, Slow, lmpulse, LEQ, constantBT, linear repeat,exponential
Synchronous Order tracking analysis [ORNV-ORD]
Analysis function Instantaneous and average spectrum,phase, order profile and overall.
Maximum rotation speed 1,200,000 RPM
Max analysis ordersetting 6.25, 12.5, 25, 50, 100, 200, 400
Number of analysis lines 25-800
Analysis bandwidth resampling method and fixed sampling method
display Simultaneous display of 3D display and tracking order, simultaneous display of time signal
Rotational torsion analysis [ORNV-IVC]
Operation method Digital Frequnecy Voltage converter
Number of analysis channels 2ch 2ch (up to 6ch as an option)
Rotation diagnosis function [ORNV-FFTDiag]
Analysis items Envelope analysis, cepstrum, self-cross function, MAX, MIN, peak detection from block data, simulated tach,
Output Channel
Number of output channels 1ch (lemo conector, include) 2ch 2ch (up to 6ch as an option)
Output waveform Sinus, step sinus, sweep sinus, chirp, multi-sinus, random (pink and white), DC voltage, record signal Sinus, step sinus, sweep sinus, chirp, multi-sinus, random (pink and white), DC voltage, record signal
Digital / Analogic converter 24 bits 24 bits
Output voltage +/- 10V +/- 10V
Output Inpedence 50 Ω 50 Ω
Frequency range ~ 100kHz ~ 40kHz
Sweep mode Sweep and step, analyze, trigger and sync, linear and log Sweep and step, analyze, trigger and sync, linear and log
Synchronization with the analysis Synchronization and free run Synchronization and free run
Output protection Stabilization with time specification and forced stop button Stabilization with time specification and forced stop buttoz
Data
Image and print Image, printing for Windows and user template creation function for Word and Excel
File TXT, UFF, MATLAB, WAV (OROS and Audio) SDF, binary, ATFX (optional)
Data entry WAV, TXT, UFF and OR20 series AE2
Dimensions / weight
Dimensions (width x height x depth mm) 35 x 110 x 185 56 × 246 × 222 102 x 260 x 311 102 x 364 x 311
Weight 0.5kg 2.8kg 5.2 kg 8.2 kg
Power supply
AC AC 100V-240V
DC USB 3.0 type C 5V 10V-28V, 20VA 10V-28V, 60VA 10V-28V, 100VA
DC battery internal operating time (built-in) NA : using PC battery 3h 2h 2h
Recommended operating temperature range 0 ℃ ~ 40 ℃ 0 ℃ ~ 50 ℃
cooling fan Fan less Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)


PC requirement

Connections Type: Ethernet, Connector: RJ45
Operating systems Windows 7 / Windows 10 / Windows 11
Recommended CPU : Quad core processor (Desktop : Intel Core i3 or Ryzen 3, Laptop : Intel Core i5 or Ryzen 5)

RAM : 6 GB
Storage : SSD, 1 GB free + storage for signals



Function

  • REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Level Meter
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 13.png Waterfall analysis (three-dimensional display)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png Signal record and post analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Resonance frequency by impact hammer
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Vibration on rotordynamics (orbit,...)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Modal Analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Power
  • REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Frequency analysis, spectrum analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Noise / acoustic analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png Time series analysis (data logger)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Vibration of rotating machines
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Customization (ex: automatic measurement)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Quality
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Monitoring

  • Catalog download

    noise and vibration catalog download






    Download











    Applications/ Case study

    Main application and commonly used functions:

    FFT analyzers are used in research and development, quality control, inspection, service departments, etc.

    Improvements in vehicle quietness, ride quality, comfort, maneuverability, etc.

    Automotive noise and vibration


    Responding to quality problems caused by vibration and noise of vehicles and rotating equipment

    rotating machine vibration


    Environmental problems caused by noise from construction machinery, office machines, home appliances, etc.

    Acoutsic and vibration application


    Problems with processing accuracy due to minute vibrations in microscopes, machine tools, semiconductor manufacturing equipment, etc.

    Accuracy measurement


    A collection of application examples using the OROS FFT analyzer OROS series

    Introducing solution examples that can be provided by various functions unique to OROS FFT analyzers.


    • Vibration measurement of cutting machine
    Vibration measurement of cutting machine


    Introducing what approach can be taken using the OROS FFT Analyzer to identify mechanical resonance problems due to changes in cutting conditions.
    Download on my.oros.com (need register)




    • Monitoring of wind power generation equipment and abnormality diagnosis
    Monitoring vibration

    Measuring vibration noise generated from rotating machines (gearboxes, generators, etc.) in wind power generation equipment is indispensable for equipment maintenance and longevity. In addition to the real-time analysis capability of rotating machinery, which is the strength of the OROS FFT analyzer, remote control / monitoring and stand-alone functions can be used to more efficiently diagnose equipment for wind power generation equipment.
    Download on my.oros.com (need to register)

    • Diesel engine camshaft rotational twist measurement
    Diesel engine camshaft rotational twist

    In the prototype of a small diesel engine, there is a problem that the rotational torsional vibration of the timing belt and the camshaft resonates, causing a large vibration. By measuring rotational fluctuations and rotational twists with high accuracy using the six tachometer channels mounted on the OROS FFT analyzer, it is clarified which rotational order is dominant for vibration.

    Download on my.oros.com (need register)



    Some references:

    airplane automotive energy measurement

    Full technical support

    • Hotline dedicated
    expert on noise and vibration

    Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.

    Tel: +33.4.76.90.52.40
    Email: customer.care@oros.com

    Your local distributor

    • User training course

    OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
    Korean vibration camp

    • Worldwide presence and accredited maintenance center

    With a worldwide coverage of distributor network and maintenance center (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
    maintenance center
    Find Your local distributor

    calibration repair metrologic instrument



    Technicians are certified on a regular basis by OROS specialists, enabling them to repair, calibrate and upgrade all OROS systems.


    • Premium contract

    1, 2 or 4 years renewable contracts to extend your warranty.

    • Access to the latest software version.
    • Full coverage on your instrument (calibration and maintenance)
    • Guaranteed turn around time (4 days) for hardware repairs and calibration
    • Privileged access to extended services at a preferential rate: urgent loan within 1 day.

    Video content

    We have released videos such as product introductions and demonstrations.

    Click here for the youtube video content page

    Schedule a demo Get a quotation Contact support