NVGate Ribbons: Analysis Tab

From OROS Wiki
Revision as of 15:03, 27 November 2023 by ChaoranDu (talk | contribs)
Jump to navigation Jump to search

Analysis4.png

In this tab, the software gathers the analyses controls. The content of this tab depends on the purchased optional plug-in.

Front-end group

Analyses Front end 2022.PNG

Control/command the Front-end sampling high frequency and low frequency. Note: The plug-in analyzer and the recorder can reduce their respective bandwidths independently. This setting fixes the acquisition time accuracy and fixes the max signal bandwidth.

See Front-end/inputs settings for details.

Player group

Analysis player 2022.PNG

Reports Tools Ribbons 328.png Connect tracks: This button allows dispatching the signal tracks (all types) to the analysis plug-ins.
Reports Tools Ribbons 329.png Record number: Define the record number (i.e. a section in the file defined during the acquisition) to be post-processed.
Reports Tools Ribbons 276.png Player settings: Give a direct access to the Player settings
Reports Tools Ribbons 333.png Playback mode: Allows choosing between a continuous and a step/step post-process.
  • Continuous: the signal analyses are processed as fast as possible between the start and stop offset.
  • Time step: the signal analyses are processed step by step. The step duration is defined by the Step setting (see hereafter). Each new step is manually (or automated by a macro) triggered through the Step setting (see hereafter).
Reports Tools Ribbons 334.png Step: Defines the time duration of the playback step for the "Time step" analysis mode. The player switches to "pause" every "time step" second.
Reports Tools Ribbons 335.png Pause/Cont.: Enables to perform the post-analysis up to the next step.


Record group

Analysis record 2022.PNG

Analysis recorder settings 2022.PNG Recorder settings: Give a direct access to the Recorder settings.
Reports Tools Ribbons 276.png Record status: Controls the recorder location and activity.
  • If the setting is set to Off, the icon is grayed. Reports Tools Ribbons 277.png
  • If the setting is set to PC, the signals are recorded on the PC HDD.
  • If the setting is set to Analyzer, the signals are recorded on the analyzer's disk.
Analysis record available.PNG Available: Display the maximum possible recording duration depending on the current recorder setup. The max duration is computed from the free space of the selected hard disk, the number of tracks (and their corresponding sampling frequency) and the number of records.

Note: in time to stop mode, the max duration may also be limited by the local available memory (PC/Analyzer) for the description blocks.

Reports Tools Ribbons 274.png Arm (CTRL+SHIFT+R): Arm the recorder. Prepare the recorder to start immediately on the run. Arming process can lap a few seconds. If the recorder is not armed, it will take a few second to achieve the arming prior to effectively start recording the data.

Note 1: modifying a setting of the analyzer will disable the arming. It is then necessary to re-arm it.
Note 2: the recorder can be armed from the ASB: (Recorder /Trigger/ Recorder).

Reports Tools Ribbons 275.png Manual trigger (CTRL+T): Generate a manual trigger event. This event is available for the event list and can be associated to the plug-in triggers (start/stop or trigger). See acquisition tab description.

Warning: While the manual trigger is not associated to a plug-in, it has no effect.

Reports Tools Ribbons 278.gif Record mark: Allow adding a mark with comments while recording. These marks are available when the signal file is edited.


Plug-in group

Analysis Plug in 2022.PNG

These buttons give a direct access to the plug-in settings. Note: only the plug-ins available with the user licenses are displayed.

Monitor settings
TDA settings
FFT settings
SOA settings
OCT settings
OVA settings

Waterfall group

Analysis Waterfall 2022.PNG

Analysis recorder settings 2022.PNG Waterfall settings: Give a direct access to the Waterfall settings.
Reports Tools Ribbons 418.png Add/Remove: Opens the Waterfall add/remove result dialog, which allows selecting the list of result to be collected by the waterfall plug-in.
Reports Tools Ribbons 422.png Mode: Select the data collection synchronization:
  • One shot: the waterfall is fulfilled in one shot from its start trigger to the stop one.
  • Continuous: the plug-in is fulfilled as a rolling buffer (FiFo) memorizing the last data only.
Reports Tools Ribbons 423.png Depth: Defines the maximum number of slices to be collected. In the continuous mode it defines the depth of the rolling buffer.
Reports Tools Ribbons 276.png Trigger selection: select the event which trigs acquisitions. A new data collection is performed each time a trigger event occurs.