Difference between revisions of "NVGate Ribbons: Home Tab"

From OROS Wiki
Jump to navigation Jump to search
Line 367: Line 367:
[[Image:Reports_Tools_Ribbons_07.png|framed|none]]
[[Image:Reports_Tools_Ribbons_07.png|framed|none]]
This group manages D-rec (Direct recording) setups. D-rec allows recording signals with the analyzer without any PC or connection.
This group manages D-rec (Direct recording) setups. D-rec allows recording signals with the analyzer without any PC or connection.
===OR362 and OR382 features===
NVGate V6.70 handles the OR36<sub>2</sub> and OR38<sub>2</sub> new features. These functionalities are fully integrated in the software offering clear and training free operations.
====D-REC, Recording without PC====
With The ''D-rec'' option your analyzer is turned into a true stand-alone recorder able to face any field situation.  With D-rec, the instrument is available from power-on to power-off without any PC or other fragile/complex consumer interfaces like PDA, smart phones and mini PC.  Setting up the front end and the recorder is operated through the new bright display with its large buttons. This interface is adapted to many situations such as outdoor, sun light, wearing gloves, etc...
Using D-rec take place in 3 different operations:
* Operating the recorder with the LCD panel,
* Preparing  predefined setups through NVGate,
* Signal recovery with NVGate,
=====PArt-1: OPerating the recorder=====
The D-rec control is made through the analyzer LCD panel. The described menus are available on analyzers sold or upgraded with the corresponding option.
After powering on the instrument the LCD panel proposes to enter the D-rec operations. There are 2 possible modes: record directly or setup the recorder.
[[Image:Release_note_02.png|framed|none]]
1. To '''record directly''', simply press the run button with the green arrow. The analyzer loads the default setup and starts recording.
[[Image:Release_note_03.png|framed|none]]
2. The setup name is displayed during the load. When recording the system displays the available disk space and recording time. The ''Run'', ''Pause'' and ''Stop'' buttons control the recorder operations.
3. To '''setup the recorder''', press the ''Pause'' button down to the D-rec arrow. The LCD will display a set of menus. The navigation is controlled by the ''Run'', ''Pause'', ''Stop'' and ''Down arrow'' buttons. Buttons actions are displayed on the LCD above the corresponding gray lines.
[[Image:Release_note_04.png|framed|none]]
The recorder support multiple records and sessions (Power On/Off). In case unexpected stop (Power failure or Mobi-Disk removal during a record) the interrupted records is automatically recovered at the next power on.
======D-rec menus Operations======
The front end and recorder setup allows to:
* Load a predefined D-rec setup (also called configuration)
* Change the recorder setup: Sampling frequency, Mode and Duration.
* Enable or disable channels: Dynamic inputs (IN), parametric inputs (DC) and external synch. (Ext). Note that each input can be activated as a dynamic or a parametric channel.
* Modify the input settings: Coupling, range and Xpod conditioner.
* Modify the DC inputs range.
* Modify the Ext. synch inputs: Coupling and range.
* Exit the D-rec mode to start with NVGate or shutdown the analyzer.
For D, E, and F, the inputs modification can be applied to a group of inputs. In the first menu set the inputs you want to change to Y (or set All to Y to modify all inputs simultaneously). Then set the coupling or range for example. It will apply to all the selected channels.
----
{|cellspacing="0" cellpadding = "10" style="border-style:solid; border-color:black; border-width:1px;" width="100%"
|<font color="#365F91">      D-rec menus Organization chart</font>
|}
[[Image:Release_note_05.png|framed|none]]
Note: Some sub-menus are not described in this diagram.
----
PART 2 -Preparing D-rec configurations with NVGate
The analyzer memorize up to 12 different setups that can be loaded on site, without a PC. A D-rec configuration concerns the front-end and recorder setup only. The configuration can be created in 2 ways: Setup the front-end and the recorder or let D-rec do it automatically from an existing analysis workbook.
======Setup the front-end and the recorder======
Run NVGate with your analyzer connected. A new item is available in the ''Setup'' menu: ''D-rec…''
[[Image:Release_note_06.png|framed|none]]
From this menu entry NVGate will propose a set of dialog boxes that guide the user through the necessary settings to build a D-rec setup. The displayed dialogs are the following:
1. Channels connection
2. Event connections
3. Recorder properties
4. Records setup management
Item #1 and #3 are exactly the same as the standard ASB dialogs for the channels connection and the recorder setup. Item #2 is also the same but only a subset of the events is handled by D-rec: Recorder trigger on Edge on Ext. synch, Level and delta level on DC inputs and periodic event only.
Item #4 allows managing the setups saved in the analyzer. The D-rec setups can be written, removed, imported and exported from this dialog box.
[[Image:Release_note_07.png|framed|none]]
To write an NVGate configuration in the hardware, press the "Add current setup" button. The current front-end and recorder settings will be saved in the analyzer. Note that all active channels (IN, DC, EXT and CAN) will automatically be connected to the recorder tracks. To delete a D-rec setup, select it in the list and press "Delete".
One of the D-rec setups saved in the analyzer can be set as the default setup when starting the D-rec. Check it in the "Default" column.
Each setup can be exported in text file to be used as a trace of the D-rec settings when using it on-site. Of course it is possible to control the front-end and recorder settings with the LCD menus, but a paper sheet or file overview is more comfortable to install the transducers and cables. To create a description file, use the "Export as txt" button.
It is possible to recover, control or modify an existing D-rec setup which is already saved in the analyzer. The "Import in ASB" function will setup the current NVGate ASB with the configuration saved in the analyzer.
======AUtomatic recorder setup======
D-rec has been designed to record without a PC. Such operations require a setup validation and are followed by a signal post-processing. With D-rec you can focus on the goal of your data acquisition rather that minding about channels, coupling and bandwidths.
With your analyzer connected you can prepare your analysis with NVGate focusing on which result you expect: spectra, order extraction, triggering threshold and others. Moreover you can validate that this front-end and analysis setup will provide the results you want.
[[Image:Release_note_08.png|framed|none]]
When your analysis setup is ready, you can add it to the D-rec setup list (see below) with the "Setup\D-rec setup(s)…" menu entry. NVGate will activate the recorder with all the active inputs. You can go and make your measurements in confidence.
=====PART 3 – recovering the SIgnal with NVGate=====
The recorded signals are recovered with the NVGate project manager. To be accessible, the measurements must be associated to one project. Like the on-line records, the signal data can stay on the Mobi-Disk or be downloaded into the host PC hard-drive.
After a D-rec session(s), the signal recovery is operated through NVGate with the Mobi-Disk connected. The Mobi-Disk connection can be:
* Running NVGate in the connected mode with the Mobi-Disk inside the hardware,
* Running NVGate in the office mode with the Mobi-Disk connected to a USB port of the host PC.
When NVGate starts and is connected to a Mobi-disk that contains signals recorded with D-rec, the following message appears.
[[Image:Release_note_09.png|framed|none]]
You can skip it and process later. In this case the menu entry "Hard-drive\manage" will show the same dialog box as the "Open Hard drive manager" button.
The Hard drive manager lists all the files (records) present in the active disk (in the hardware or USB connected). The records made in stand-alone are automatically named with the date/time based on the analyzer real-time clock.
To recover these files in the project manager:
1. Select the measurements to process. Automatic selection is available from the top combo-box (select ''unavailable in project manager'') or manual selection with the mouse and CTRL or SHIFT buttons.
2. Press the bottom "Add to Project Manager" button to add these records into one of your projects.
The signal files are now ready for visualization, post-processing and export. The data are still on the Mobi-Disk. Use the download function to copy it on the PC hard-drive.
* To be previewed the files must be loaded into the player with the ''Load and preview'' function. The signal previewing computation may take a few seconds, it occurs one time only.
* When exportation is needed, the files must be downloaded to the PC hard drive first.
[[Image:Release_note_10.png|framed|none]]


===OR10 Steup===
===OR10 Steup===

Revision as of 08:53, 5 May 2020

Home tab Overview

This first tab features 2 mains services, which are proposed when entering the software (first time and regularly)

  • Entering directly in the different modes of the software (start group)
  • Set up the general options of the instrument (other groups).


Start Group

This group gathers the entry points for setup selection or building tools as well as the access to the different software modes (measurements editor, post analyze, model load).

Start… Open the NVGate Start dialog which is dedicated to make the first steps in the software. The start dialog is also displayed at each NVGate Start until the user deactivated the option in the bottom left of the dialog.

  • Entering in a project

While launching NVGate or click on this button, operator is invited to select or create a project. This step allows reloading or defining the context.

Selecting Open Project opens the Open Project dialog which behaves as the single Item selection.

V10 release 16.png


Select your project and click Open button.

Selecting New project opens the following dialog:

V10 release 17.png


Fulfill the necessary properties and comment to describe the context of this project and click on Ok button. This bring you to the setup

Select Inputs

Available from both the bottom bar and Home\Start\Select Inputs this window allows selecting the inputs to be used and setups their acquisition.

See the GoToResult page for more information.

Post analysis

File:Post analyse.png

This button is used to playback recorded signals that can be computed in post analysis mode. In this way you can re-inject the recorded signals into any plug-in analyzer (Monitor, FFT, 1/n Octave...). It is also possible to play back a recorded signal through the Output during On-line analysis.

Press the Post Analyze button. This will display a selection of signal files available for post-analysis:

See player page for more details.


Edit Measurement

The Edit measurement allows reviewing the measurements for comparison, modification or report. An edited measurement comes as a foreground layer on the top of the current analysis one.

Measurement edition is available from the ribbon Home/Start/Edit Measurement.

When a Measurement is edited it is possible to update it and/or to make a report.

Setup Group

In both above open project cases, the project is opened, no setup is loaded. The Setup is loaded further this first action. There are few ways to load a setup prior being ready for acquisition and analyses.

Check the Load setup box in the open project dialog in order to select the setup while exiting the Open project one.

Use the Home/Setup/Load ribbon button.

The load setup dialog behaves as a single Item selection. It allows loading setups from Models Measurements and Projects or creating setups for on-line or post-analysis:


V10 release 18.png

While in Model or Measurement load, the details section (right bottom side) shows which results are saved by the selected setup.

Load a Model: Loaded Models offer additional features;

  • Model properties will inherit to the measurements
  • Loaded Model name reminded in the Ribbon; Home/Setup with the
V10 release 19.png

icon. This Model will remain active until a reset setup

V10 release 20.png

is applied or another setup is loaded.

  • When the measurement are shared out of NVGate or collated to NVGate the associated model will be transferred with the measurement.
  • Loaded Model can be modified to adjust to current situation. The modified setup is saved in the Measurement, but the original Model remains unmodified. This allows providing predefined setups which are not modified by specific usage (adjustments, operator's error, etc.) ensuring reproducibility.
  • You can modify and save the setup with the Home/Setup/save as model button
V10 release 21.png

. Associated model properties will be propsoed in teh savec as model dialog. This allows updating an exitsing Model keeping its properties. Load a Measurement's setup: The setup used to generate the results of the selected Measurement will be reloaded.

This feature allows reproducing faithfully exiting measurements for prototyping fine tuning or trend analyses. OROS recommend saving all repeated measurements in the same project.

Create a setup from scratch: This sis available for on-line or post-analysis. Both options will reset the current setup to default values before building the new setup.

  • On-line opens the Channel selection dialog as usual.
  • Post-analysis will first require selecting a file to be analyzed with the Select signal dialog. Similarly to select model one the right side of the dialog shows the Measurement properties. This information allows rapidly finding the searched signal.
V10 release 22.png

Pre-defined setups

OROS provides various predefined models that contains basic and advanced setup examples of analysis. These setups are available from the Load Model dialog.

This setup contains customized items:

  • Front-end setup
  • Analysis setup
  • Layouts
  • Save setup
  • Control panel

Select the Tree view in the Load setup dialog to see the directories using the Flat/tree button


Usersmanual 108.png

Tree view

Quick directory contains setups of the instrument for either post-processing or on-line analysis.

The mapped directory is the quick directory in the workbook library which is defined in the NVGate Environment paths. Default is: C:\OROS\NVGate data\Workbook Library\Quick\. It is possible to add additional models in this directory according to your organization chart.

Quick Models name defines the characteristics of the corresponding analyses:

AAA_M_W_N

  • AAA is the analysis mode (FFT, REC, ORD, etc..)
  • M is the mode: O=On-line, P=Post-analysis
  • W is present for waterfall results (profile, 3D)
  • N is the number of channels
Advanced Models

This directory shows applications-oriented examples.

The mapped directory is the advanced directory in the workbook library which is defined in the NVGate Environment paths. Default is: C:\OROS\NVGate data\Workbook Library\advanced\.

User’s models

This directory holds the Models saved by the users of the NVGate installed in the current PC.

Working set

Even if the Share/Collate features allow reducing the number of data directly available in the working set (NDLR the NVGate environment), it is useful being able to reduce the visible Items to the current concern. The Filter Project provides such selection.

Filter project

This function selects what is visible in the working set. It is available from the ribbon: Home/Working Set/Filter Project.

Use the filter and columns sorting to select which set of Project/Measurements will be visible. Click on Filter to view only selected Items, select No Filter to view all Items.

The visibility filtering applies on all Item Selection Browsers, Set Selection Browsers and Project Manager.

Reports Tools Ribbons 231.png

Workspace: show/Hide the workspace windows that contains the Analyzer Setting Browser (ASB), the Project Manager (PM) and the Control Panel (CP).

Only one panel is displayed at a time. The user may switch between panels by clicking on the title bar of the desired sheet.

Reports Tools Ribbons 233.png

Log window: This windows track all changes in the analyzer. Logs are arranged in 3 separate tabs:

  • Analyzer settings: Display all users’ and dependencies related changes in the ASB.
  • Warning: Displays dynamic warnings related to the current setup (ex A & C acoustic filters are no more available when the sampling frequency is lower than 25.6 kHz). Raising a warning will automatically show the log window during 3 sec.
  • Macro trace: log window for macro execution and debugging.

Recommended location: Bottom, Docked

Reports Tools Ribbons 235.png

Status: Displays the current status of the plug-ins (see chapter 1 ASB for details). General statuses are displayed in the bottom status bar, the Status window is made to show advanced status for accurate control of the acquisition/analyses. To add the statuses in this window, right click in the selected plug-in and select View states

Recommended location: Bottom, Docked

Example for the FFT plug in you may display:

  • Block Overload: corresponds to the instantaneous overload indication within 1 FFT trigger block, for instance during a few milliseconds overload occurred, the current trigger block indicates overload, the following trigger block may not have any overload so indication "no overload" will be seen
  • Analysis Overload: corresponds to overload indication over the measurement period. It means that during the whole measurement period there was (or not) an overload.

For instance: during a measurement, a short overload occurs, Block Overload will indicate "Overload on Channel x", Analysis Overload will indicate "Overload on Channel x", after overload occurred, Block Overload will indicate "No Overload", Analysis Overload will indicate "Overload on Channel x".

When pressing run again, Block Overload and Analysis Overload status will be reset.

When using Automatic overload rejection in FFT, Analysis Overload status take into account any occurring overload despite FFT block rejecting them for FFT calculation, the user will anyhow keep a trace of occurred overload.

These windows can be docked or floating. Environment windows are to be displayed temporarily for advanced setup. It is recommended to hide these windows for standard measurement/analyses.

Preferences group

These buttons provide direct access to the user’s preferences.

The user’s preferences are gathered in one unique dialog with multiple tabs. It is possible to navigate in these tabs from any of the entry point (the described buttons).

See User Preferences for details

General: Enter the preferences setting at the 1st tab. It allows customizing the scales font size, the refreshing speed as well as default specialized modes

Units & Quantities: Open the physical quantity tabs of the user’s preferences. It allows creating, modifying and removing the units and physical quantities used by the NVGate interface. Reminder: NVGate process SI units. The selected Units with are used for display only, the data are not modified by the units changes.

Data Management: Open the measurement properties setup. This tool allows managing the default and user defined properties. These property values are saved with the measurement and used to qualify it. Later, they may be incorporated into reports and for search functions.

Share and collect dataset

This function transfers Projects, Measurements, Models and associated attachments from the NVGate Data to a common directory and reciprocally.

Collate-share.png

These transfers operate in both direction; Share data from the NVGate PC to a common base ; Collate the data from a common base to the PC. The target/source directory can be in the PC, on the LAN or on an external device.



Most of transfer conflicts and errors are automatically managed especially the merge of Projects, Measurements and Attachments. Most of them are solved automatically.

In case of ambiguous conflicts, operator is asked to provide the action in a Windows style .

V10 release 02.png

When possible, source and target directory are accessible through the hyperlinks.

Data Traceability Each transfer (share and Collate) generates a report in 2 ways:


Share Dataset

The Datasets are shareable from the ribbon Home/Dataset:

V10 release 24.png

The Share Dataset dialog behaves as multi-selection featuring the following extra settings:

1. The path of the target directory. Shared Items will be deposited at the root of this directory for the Project/Measurement hierarchy. Models will be deposited in a subfolder named "Folder".
Used targets are memorized and made available with the down arrow at the right.

2. Selection of what will be shared.

  • Project/Measurements will transfer selected Projects and Measurements. The Models associated with selected Measurements will also been carried on.
    Used to share measurement data with their setups.
  • Models: Only the selected Models will be transferred.
    Used to spread Models to the measurement teams.

3. Define how to transfer:

  • Copy keeps the data on the NVGate data locally while transferring a copy of selected ones
  • Move, first copies the dataset and then delete the copied from the NVGate data.
  • Include signals carries on the time series files when selected. Leave the time series files on the local NVGate data when unselected.
    Note: In order to avoid data loss, the Include signals is forced to "select" when Move is chosen.

Note: that Share can also be used for dataset backup on the NVGate PC, an external disk or on the network.

Collate Datasets

Collate [kəˈleɪt] verb. To gather together information from different sources in order to study it carefully

Sharing data means recovering those data in local NVGate instances. The Collate function allows selecting and gathering dataset from common directories to the local NVGate data.

Collate dataset is available from the ribbon Home/Dataset:

V10 release 25.png

Main difference is that the searched path is not limited at the Source level. The Collate function will take in account in depth hierarchy of the source directory among all its subdirectories.

This allows having a directory structure on the data set common base and being able to search in with the properties only for ones that do not know the directory organization.

Import

See Export/import.

Disk group

PC and Mobi-Disc management tools

Reports Tools Ribbons 242.png

Active Disk: Select the active disk. The active disk is the one which is mapped by the project manager. The disk where a signal file is located must be the active one in order to load it on the player (play back, post process, exploration). The active disk can be:

Reports Tools Ribbons 243.png

The PC one. Available in office mode only.

Reports Tools Ribbons 244.jpg

One of the Mobi-disk connected through a USB cable. Available in office mode only.

Reports Tools Ribbons 245.jpg

The Analyzer disk (Mobi-Disk or fixed). Available in connected mode only.

Manage: Open the disk manager in order to manage the signal files saved on it. See "Disk management" topic from Chapter 3: "Hardware Management" for details.

Format: Format the active disc. Attention all saved data on the formatted disk will be definitely deleted. Not available when PC disk is selected. See "Disk management" topic from Chapter 3: "Hardware Management" for details.

Download: Select available signal file on the active disk that match the project present on the project manager. To recover signal files from a record session made with another PC use the manage button. See "Disk management" topic from Chapter 3: "Hardware Management" for details.

User group

NVGate operates with users’ preferences and authorizations. Personalized profiles can be memorized and recalled while starting the software.

A user profile contains:

  • Default display preferences (colors, scale type, mode, units, etc..)
  • Saving modes (default name, incrementing, confirmation mode, data protection and visibility)
  • Waterfall (view, default reference, colors, extractions, filling and type)
  • Marker (colors, limits, interpolation)
  • Report colors palette
  • Units for each physical quantity
  • Export modes
  • Floating/docked windows location and visibility

The User group allows managing NVGate users’ profiles.

User button Part 1: It allows selecting the current user. Attention changing from one user to another one will reset the current NVGate analysis configuration to the default one defined by the new user.

Reports Tools Ribbons 250.png

User button Part2: It allows creating and deleting users from the active .usr profile files.

  • New: Used to create a new user
Reports Tools Ribbons 251.png

First name: First name of the user may be left empty. The first name is automatically formatted so that the first character is in upper case and the others are in lower case letters.

Last name: Last name of the user must be filled in. The last name is automatically formatted in letters.

Password: If selected, the user will have to enter his password to launch NVGate

Access level

-Full: The user is not limited within NVGate

-Restricted: The user is not authorized to access to all the functions of NVGate. The main characteristics of this type of user are:

Authorized actions Unauthorized actions
  • Create measurements
  • Modify settings from the Control Panel
  • Execute macros from the control panel
  • Load projects from a predefined list
  • Print reports; Move markers
  • Save a project
  • Close or modify the windows
  • Modify the settings in the ASB
  • Use the toolbars that have not been authorized by the administrator


Reports Tools Ribbons 252.png

Administrator: Allows Switching to a non-restricted user profile for administration of the current restricted user rights. In this case the current analyzer setup is not modified.

Reports Tools Ribbons 253.png

Password: Used to change the password. If necessary, the user must enter his current password and then enter the new password twice

Reports Tools Ribbons 254.png

Warning: Due to the GUI modifications, the restricted user profile limitations do not apply on NVGate version 7.00 and further until new notification. It is possible to run NVGate7 with the Legacy V6.00 interface to benefit from the restricted user capabilities. For such purpose runs NVGate7 with the following parameter: -legacy

By default the user is named ’Default user". User

The user profiles are saved in a file called NVGate.usr located in the NVGate.exe directory. This file is automatically created at NVGate start when it is absent. Attention: deleting the NVGate.usr file delete all users’ preferences including the default setting proposed by OROS.


It is possible to temporary change .usr file for special applications. To start NVGate with .usr different from the default one (NVGAte.usr) add the following to the command line: -usr=myfile.

Transducer

See transducer page.

D-Rec group

Reports Tools Ribbons 07.png

This group manages D-rec (Direct recording) setups. D-rec allows recording signals with the analyzer without any PC or connection.

OR10 Steup

File:OR10 setup.png

See OR10 stand alone page