Difference between revisions of "FFT Spectrum Analyzer Multipurpose"

From OROS Wiki
Jump to navigation Jump to search
 
(27 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{#seo:
{{#seo:
|title=FFT Spectrum analyzer for acoustic and vibration
|title=FFT Spectrum analyzer for acoustic and vibration - Modal analysis
|keywords= FFT analyzer, Spectrum analyzer, analyzer acoustic and vibration, Octave analyzer, third octave, FFT analysis software, order tracking measurement, turbomachinery Orbit.
|keywords= FFT analyzer, vibration analyzer, Spectrum analyzer, analyzer acoustic and vibration, Octave analyzer, third octave, FFT analysis software, order tracking measurement, turbomachinery Orbit, fast fourier transform, modal analysis
|description= OROS portable hardware multichannels Instrument with real time software, easy to operate .
|description= OROS portable hardware multichannels Instrument with real time software, easy to operate .
|image=FFT analyzer hardware.jpg
|image=FFT_analyzer_hardware_2.webp
}}
}}
__NOTOC__
__NOTOC__
[[File:FFT_analyzer_hardware_2.webp|frame|150px|left|FFT analyzers]]
[[File:O4_range Gamme O4 + OR10 + OR35 + OR36 + OR38.png|frame|left|FFT analyzers|alt=Analyzer acoustic vibration multichannel]]
The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.  
The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.  


We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.  
We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.  


In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB (125 dB for OR34). These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.
In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB. These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.




Line 21: Line 22:




<gallery gallery mode="packed-hover" align= left >
<gallery gallery="" mode="packed-hover" align="left">
TWanalyzer2.jpg|Analyzer Cascade mode
File:TWanalyzer2.jpg|alt=Vibration measurement up to 1000 channels|Analyzer Cascade mode
Situation_auto_hammer_pc.jpg|Modal FRF measurement
File:Situation auto hammer pc.jpg|alt=Hammer test on automative in anechoic room|Modal FRF measurement
Auto_anechoic_chamber2.webp|Acoustic Sound intensity
File:Auto anechoic chamber2.webp|alt=Sound intensiyt measurement in anechoic room|Acoustic Sound intensity
turbo orbit.JPG|Vibration on trubomachinery
File:Turbo orbit.JPG|alt=Turbomachinery orbit vibration measurement|Vibration on trubomachinery
Or34_situation.jpg|NVH automotive measurement
File:Or34 situation.jpg|alt=NVH measurement on a car|NVH automotive measurement
airfrance.jpg|In flight measurement
File:Airfrance.jpg|alt=Acoutic measurement with octave anlyzer in a plane|In flight measurement
</gallery>
</gallery>


Line 41: Line 42:
* Equipped with an output channel as a standard  
* Equipped with an output channel as a standard  
* Built-in internal battery as a standard
* Built-in internal battery as a standard
* Record, FFT analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
* Record, Fast Fourier Transform analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
* Realtime measurements and post-analysis can be performed with the same software platform ([[NVGate]])
* Realtime measurements and post-analysis can be performed with the same software platform ([[NVGate]])
* In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS  (**)
* In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS  (**)
Line 57: Line 58:


==Introducing the hardware==
==Introducing the hardware==
[[File:hardware.png|right|Spectrum analyzer|alt=OROS instrument analyzer for noise and vibration]]
===Small and lightweight===


===Small and lightweight===
[[File:model.jpg|200px|right|Spectrum analyzer]]


OR10-8ch model: 0.8kg
OR10-8ch model: 0.8kg


OR34: 4ch model: 1.5kg
O4: 4ch model: 0.5kg


Or35 TW: 10ch model: 3.0kg
OR35 TW: 10ch model: 3.0kg


OR36 TW: 16ch model: 5.2kg
OR36 TW: 16ch model: 5.2kg


OR38 TW: 32ch model: 8.2kg
OR38 TW: 32ch model: 8.2kg
<br>
<br>
<br>
<br>
<br>
<br>
<br>
Line 75: Line 79:


===Ethernet LAN interface===
===Ethernet LAN interface===
[[image:laninterface.PNG|right|FFT analyzer ethernet]]
[[image:laninterface.PNG|right|FFT analyzer ethernet|alt=Back of FFT analyzer : ethernet connection for PC]]
Achieves high-speed communication with a PC through an ethernet LAN interface
Achieves high-speed communication with a PC through an ethernet LAN interface
<br>
<br>
Line 85: Line 89:


===Built-in battery===
===Built-in battery===
OR10/ OR34/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.
OR10/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.


OR10 can be operated by battery for 4hours
OR10 can be operated by battery for 4hours
Line 92: Line 96:


TW OR36 / TW OR38 can be operated by battery for 2 hours.
TW OR36 / TW OR38 can be operated by battery for 2 hours.
04 operate with battery PC.


===External battery===
===External battery===
[[File:external battery.PNG|200px|right|external battery on analyzer]]
[[File:external battery.PNG|200px|right|external battery on analyzer|alt=External battery on spetrum analyzer]]


We provide a compact and lightweight external battery that can be installed on all models.
We provide a compact and lightweight external battery that can be installed on all models.
Line 119: Line 125:
=== Measure From Sound / Vibration and Strain Gauge / Temperature ===
=== Measure From Sound / Vibration and Strain Gauge / Temperature ===
(OR35 / TW OR36 / TW OR38 only)
(OR35 / TW OR36 / TW OR38 only)
[[File:Usersmanual_32.jpg|200px|right|Conditioner on analyzer]]
[[File:Usersmanual_32.jpg|200px|right|Conditioner on analyzer|alt=Temperature and straing conditionner]]
By mounting a [[XPod_Bridge_-_Strain_gauge|strain gauge conditioner]] and [[NVGate_X-Pod:_Temperature_probe_conditioner|thermocouple conditioner]] on the Oros FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.
By mounting a [[XPod_Bridge_-_Strain_gauge|strain gauge conditioner]] and [[NVGate_X-Pod:_Temperature_probe_conditioner|thermocouple conditioner]] on the Oros FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.


Line 129: Line 135:


===CAN-bus Module Available ===
===CAN-bus Module Available ===
[[File:Can_Bus.jpg|150px|right|Can bus measurement]]
[[File:Can_Bus.jpg|150px|right|Can bus measurement|alt=Can bus to add on OROS instrument]]
(OR10/ TW OR35 / TW OR36 / TW OR38 only)
(OR10/ TW OR35 / TW OR36 / TW OR38 only)


Line 139: Line 145:
(OR35 / TW OR36 / TW OR38 only)
(OR35 / TW OR36 / TW OR38 only)


[[File:d_rec.PNG|150px|right|Data acquisition recorder]]
[[File:d_rec.PNG|150px|right|Data acquisition recorder|alt=Vibration time signal Measurement without PC]]
The FFT analyzer is equipped with a [[NVGate_D-Rec|record-only button]]. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.
The FFT analyzer is equipped with a [[NVGate_D-Rec|record-only button]]. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.


Line 148: Line 154:




In addition, the back of the FFT Spectrum Analyzer Multipurpose is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors. 


[[File:FFT_analyzer.jpg|600px|Back of the hardware]]
In addition, the back of the Fast Fourier Transform Spectrum Analyzer Multipurpose is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors. 
 
[[File:FFT_analyzer.jpg|600px|Back of the hardware|alt=all the plug available on the backside of instrment]]
<br>
<br>
<br>
<br>
Line 170: Line 177:
The Oros series FFT spectrum analyzer multifunction uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.
The Oros series FFT spectrum analyzer multifunction uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.


[[File:home3.PNG|800px|software ribbon]]
[[File:home3.PNG|800px|software ribbon|alt=NVgate ribbon technology]]


===One-click Setting Function===
===One-click Setting Function===
Line 176: Line 183:




[[File:FFT_analyzer_spectrum.png|500px|FFT spectrum]]
[[File:FFT_analyzer_spectrum.png|500px|FFT spectrum|alt=Parameters easy to change]]


===Control Panel===
===Control Panel===
In addition, the OROS FFT spectrum analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the [[NVGate_Control_Panel|control panel]]. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.
In addition, the OROS FFT spectrum analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the [[NVGate_Control_Panel|control panel]]. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.


[[File:control pannel_test.png|700px|Software FFT settings]]
[[File:control pannel_test.png|700px|Software FFT settings|alt=Control easily the software]]


===Various filters can be applied to recorded signals & FFT analysis results===
===Various filters can be applied to recorded signals & FFT analysis results===
Line 192: Line 199:
Any order component can be extracted in real time from the color spectrum graph.
Any order component can be extracted in real time from the color spectrum graph.


[[File:extraction.jpg|Synchronous order analysis extraction]]
[[File:extraction.jpg|Synchronous order analysis extraction|alt=order extraction on vibration software]]


Easy-to-read Layout
Easy-to-read Layout
Line 209: Line 216:
'''Layout 1''': Record waveform, FFT analysis result, order ratio analysis result displayed
'''Layout 1''': Record waveform, FFT analysis result, order ratio analysis result displayed


[[File:Fft_extraction_data.jpg|Order extraction]]
[[File:Fft_extraction_data.jpg|Order extraction|alt=Recorder and FFT together]]




'''Layout 2''': Display 3D frequency analysis results and 3D order ratio analysis results
'''Layout 2''': Display 3D frequency analysis results and 3D order ratio analysis results


[[File:waterfall_extract_order.jpg|3d display order spectrum ]]
[[File:waterfall_extract_order.jpg|3d display order spectrum |alt=NVGate software on line measurement]]




Line 221: Line 228:
'''Layout 3''': Display 3D '''octave analyzer''' analysis results
'''Layout 3''': Display 3D '''octave analyzer''' analysis results


[[File:octave waterfall.jpg|Octave acoustic measurement 3d display]]
[[File:octave waterfall.jpg|Octave acoustic measurement 3d display|alt=Acoustic measurement with octave]]


===Easy operation <Graph layout selection button>===
===Easy operation <Graph layout selection button>===
Line 228: Line 235:
You can easily arrange windows just by selecting the grid menu.
You can easily arrange windows just by selecting the grid menu.


[[File:gridwindows_PNG.PNG|NVGate icone]]
[[File:gridwindows_PNG.PNG|NVGate icone|alt=Grid icone]]




Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.
Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.


[[File:excel_report.jpg|400px|FFT spectrum Report function]]
[[File:excel_report.jpg|400px|FFT spectrum Report function|alt=export your data]]




Line 245: Line 252:
Simply click the report button located on the ribbon interface to create a [[NVGate_Report|report]] file containing the current measurement results.
Simply click the report button located on the ribbon interface to create a [[NVGate_Report|report]] file containing the current measurement results.


[[File:allwindows_.PNG|NVGate report]]
[[File:allwindows_.PNG|NVGate report|alt=report all windows]]


• The content of the report is customizable. Customize it to the format that best suits your needs.
• The content of the report is customizable. Customize it to the format that best suits your needs.


[[File:report-customize.jpg|500px|customize FFT analyzer software report]]
[[File:report-customize.jpg|500px|customize FFT analyzer software report|alt=Post analysis vibration software]]


===Measurement data search function===
===Measurement data search function===
[[File:pc cloud.PNG|right|Data stored]]
[[File:pc cloud.PNG|right|Data stored|alt=cloud vibration data]]
Various information (meta-data) can be added when saving measurement data.
Various information (meta-data) can be added when saving measurement data.
You then can search for measurement data and projects based on the added information.  
You then can search for measurement data and projects based on the added information.  
Line 263: Line 270:
* Measurement site  
* Measurement site  
* User
* User
[[File:filter_project.PNG|550px|meta data on noise and vibration software NVGate]]
[[File:filter_project.PNG|550px|meta data on noise and vibration software NVGate|alt=Acoustic and vibration search function]]


===Fail judgment function as standard===
===Fail judgment function as standard===
Line 270: Line 277:
In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.
In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.


[[File:fail_test.JPG|Pass/fail test on resonnance frequency impact hammer test]]
[[File:fail_test.JPG|Pass/fail test on resonnance frequency impact hammer test|alt=Failed pass test on resonnance frequency test]]


===Automate post-analysis processing===
===Automate post-analysis processing===
Line 277: Line 284:




[[File:BPP2.jpg|Post processing acoustic measurement batch ]]
[[File:BPP2.jpg|Post processing acoustic measurement batch |alt=Offline measurement]]


==specification==
==specification==
Line 284: Line 291:
{| class=wikitable style="width:100%;" style="text-align:center;"
{| class=wikitable style="width:100%;" style="text-align:center;"
! style="width:15%|
! style="width:15%|
! style="width:17%|OR34
! style="width:17%|O4
! style="width:17%|OR10
! style="width:17%|OR10
! style="width:17%|OR35
! style="width:17%|OR35
Line 311: Line 318:
|-
|-
! Input voltage range
! Input voltage range
| +/- : 17.5mV - 10V with auto range function
|colspan=5| +/-: 100mV to +/-: 40V (auto range function)
|colspan=4| +/-: 100mV to +/-: 40V (auto range function)
|-
|-
! Maximum voltage
! Maximum voltage
| 40V
|colspan=5| 60V
|colspan=4| 60V
|-
|-
!Anti-Aliasing filter  
!Anti-Aliasing filter  
Line 328: Line 333:
|-
|-
!Dynamic range
!Dynamic range
|colspan=5| ± 0.05dB (1kHz
|colspan=5| >140dB
|-
|-
!Channels-to-channels phase accuracy
!Channels-to-channels phase accuracy
Line 334: Line 339:
|-
|-
!Input filter
!Input filter
|colspan=5| Acoustic A, C r, low pass, high pass, band pass, integrator, differentiator, time axis integration function
|colspan=5| Acoustic A, C, Z, low pass, high pass, band pass, integrator, differentiator, time axis integration function
|-
|-
!Sampling frequency of the signal
!Sampling frequency of the signal
Line 349: Line 354:
|-
|-
!Voltage range
!Voltage range
|colspan=1|+/- 300mV  10V
|colspan54|+/- 300mV  40V
|colspan=4|+/- 300mV  40V
|-
|-
!colspan=6| DC input
!colspan=6| DC input
Line 401: Line 405:
|-
|-
!Analysis frequency range
!Analysis frequency range
|colspan=5|0.8Hz-40kHz
|colspan=1|0.8Hz-100kHz
|colspan=4|0.8Hz-40kHz
|-
|-
!FFT block size
!FFT block size
Line 518: Line 523:
|-
|-
!Number of output channels
!Number of output channels
|colspan=1| 1ch
|colspan=1| 1ch (lemo conector, include)
|colspan=1| no output
|colspan=1| no output
|colspan=1| 2ch
|colspan=1| 2ch
Line 546: Line 551:
|-
|-
!Frequency range
!Frequency range
|colspan=1|~ 40kHz
|colspan=1|~ 100kHz
|colspan=1|
|colspan=1|
|colspan=3|~ 40kHz
|colspan=3|~ 40kHz
Line 582: Line 587:
|-
|-
!Dimensions (width x height x depth mm)
!Dimensions (width x height x depth mm)
|45 x 205 x 154
|35 x 110 x 185
|37 x 174 x 120
|37 x 174 x 120
|56 × 246 × 222
|56 × 246 × 222
Line 589: Line 594:
|-
|-
!Weight
!Weight
| 1.5kg
| 0.5kg
| 0.85kg
| 0.85kg
| 2.8kg
| 2.8kg
Line 601: Line 606:
|-
|-
!DC  
!DC  
| 10V-28V, 15VA
| USB 3.0 type C 5V
| USB 15V
| USB 15V
| 10V-28V, 20VA
| 10V-28V, 20VA
Line 608: Line 613:
|-
|-
!DC battery internal operating time (built-in)  
!DC battery internal operating time (built-in)  
| 15 minutes
| NA : using PC battery
| 4h
| 4h
| 3h
| 3h
Line 615: Line 620:
|-
|-
!Recommended operating temperature range
!Recommended operating temperature range
|colspan=4| 0 ℃ ~ 50 ℃
|colspan=3| 0 ℃ ~ 40 ℃
|colspan=3| 0 ℃ ~ 50 ℃
|0 ℃ ~ 45 ℃
|0 ℃ ~ 45 ℃
|-
|-
!cooling fan
!cooling fan
|colspan=1|Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)
|colspan=1|Fan less
|colspan=1|Fan less
|colspan=1|Fan less
|colspan=4|Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)
|colspan=4|Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)
Line 658: Line 664:
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_Recorder|Signal record and post analysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_Recorder|Signal record and post analysis]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT_Analyzer|Resonance frequency measurement by vibration]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT|Resonance frequency by impact hammer]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[ORBIGate|Vibration and rotordynamics]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[ORBIGate|Vibration on rotordynamics (orbit,...)]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Modal|Modal Anlysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Modal|Modal Analysis]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Power|Sound Power]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Power|Sound Power]]
Line 671: Line 677:
{| class="wikitable"  
{| class="wikitable"  
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT_Analyzer|Frequency analysis, spectrum analysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT|Frequency analysis, spectrum analysis]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Octave_Analyzer|Noise / acoustic analysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Octave_Analyzer|Noise / acoustic analysis]]
Line 677: Line 683:
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_D-Rec|Time series analysis (data logger)]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_D-Rec|Time series analysis (data logger)]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Synchronous_Order_Analysis|Vibration / noise analysis of rotating machines]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Synchronous_Order_Analysis|Vibration of rotating machines]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Ribbons:_Automation|Customization such as automatic measurement]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Ribbons:_Automation|Customization (ex: automatic measurement)]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Quality_Lite|Sound Quality]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Quality_Lite|Sound Quality]]
Line 752: Line 758:
*[https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
*[https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
*[https://www.oros.com/solutions/structural-dynamics/frequency-response-function-frf-acquisitions/ Resonance frequency measurement by vibration]
*[https://www.oros.com/solutions/structural-dynamics/frequency-response-function-frf-acquisitions/ Resonance frequency measurement by vibration]
*[https://www.oros.com/solutions/structural-dynamics/modal-analysis/ Experimental mode analysis]
*[https://www.oros.com/solutions/structural-dynamics/modal-analysis/ Experimental modal analysis]




Line 794: Line 800:
*'''Much more Application note on [https://my.oros.com/ my.oros.com]'''
*'''Much more Application note on [https://my.oros.com/ my.oros.com]'''


<gallery gallery mode="packed-hover" align= left>
<gallery gallery="" mode="packed-hover" align="left">
File:end of line turbine test.jpg|Allen Gears: gear box rotating vibration
File:End of line turbine test.jpg|alt=Gear box measurement with accelerometers|Allen Gears: gear box rotating vibration
File:in flisght helicopter vibration measurement.PNG|Conrad: On helicopter vibration measurement
File:In flisght helicopter vibration measurement.PNG|alt=motor vibration order extraction|Conrad: On helicopter vibration measurement
File:mecalac sound power.jpg|Mecalac: Sound power acoustic measurement
File:Mecalac sound power.jpg|alt=Octave and sound level meter with microphone|Mecalac: Sound power acoustic measurement
File:In-porsche.JPG|Porsche: acoustic sound quality measurement  
File:In-porsche.JPG|alt=Automotive octave waterfall analyzer with order extraction|Porsche: acoustic sound quality measurement
File:sound power2.jpg|Bosch: Sound power acoustic measurement on anechoic chamber
File:Sound power2.jpg|alt=Acoustic room with microphone |Bosch: Sound power acoustic measurement on anechoic chamber
File:vibration on block press.jpg|IFF Weimar: Vibration on block press
File:Vibration on block press.jpg|alt=Shock test measurement|IFF Weimar: Vibration on block press
File:blade vibration.jpg|Blade vibration
File:Blade vibration.jpg|alt=Spectrum analyzer on the field|Blade vibration
File:elevator shaft vibration.jpg|Sicor: Elevator motor vibration
File:Elevator shaft vibration.jpg|alt=accelerometer and microphone analysis|Sicor: Elevator motor vibration
File:dBVib_01.JPG|dBVib: On site measurement on turbomachinery
File:DBVib 01.JPG|alt=Orbit shaft center line and fluid film bearing vibration|dBVib: On site measurement on turbomachinery
File:equilibrage 005.jpg|BSCA: Vibration balancing test
File:Equilibrage 005.jpg|alt=Acceleromters on each side of the plan|BSCA: Vibration balancing test
File:washingmachine.jpg| Washing macine FRF resonnance frequnecy test
File:Washingmachine.jpg|alt=Bump test geometry with modal software|Washing macine FRF resonnance frequnecy test
File:master_at_work.jpg| Vibration measurement
File:Master at work.jpg|alt=team watching overall value of accelerometer|Vibration measurement
File:windturbine.jpg|GDF SUEZ: Windturbine monitoring measurement
File:Windturbine.jpg|alt=Motor of wind turbine analysis|GDF SUEZ: Windturbine monitoring measurement
File:3 OR38.JPG|3 analyzers working together
File:3 OR38.JPG|alt=multichannel analyzer portable  |3 analyzers working together
File:turbine.JPG|Alstom: Measurement on turbine
File:Turbine.JPG|alt=hydro vibration measurement|Alstom: Measurement on turbine
</gallery>
</gallery>


Line 817: Line 823:
'''Some references:'''
'''Some references:'''


[[File:reference.PNG|800px|Analyzer reference]]
[[File:reference.PNG|800px|Analyzer reference|alt=airplane automotive energy measurement]]


===Full technical support===
===Full technical support===
Line 824: Line 830:
* '''Hotline dedicated'''
* '''Hotline dedicated'''


[[File:Custcare team2 web-1.jpg|OROS Customer Care Team|right|150px|left|support FFT analyzer]]
[[File:Custcare team2 web-1.jpg|right|150px|support FFT analyzer|alt=expert on noise and vibration]]
Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.
Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.


Line 836: Line 842:
OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
<br>
<br>
[[File:user_day.jpg|Acoutsic and vibration training]]
[[File:user_day.jpg|Acoutsic and vibration training|alt=Korean vibration camp]]
<br>
<br>
<br>
<br>
Line 844: Line 850:
With a worldwide coverage of distributor network and maintenance center (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
With a worldwide coverage of distributor network and maintenance center (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
<br>
<br>
[[File:map_world_distributor.JPG|Spectrum analyzer worldwild seller]]<br>
[[File:map_world_distributor.JPG|Spectrum analyzer worldwild seller|alt=maintenance center]]<br>
[https://www.oros.com/find-us/ Find Your local distributor]
[https://www.oros.com/find-us/ Find Your local distributor]
[[File:repair.jpg|200px|right|repair hardware analyzer]]
[[File:repair.jpg|200px|right|repair hardware analyzer|alt=calibration repair metrologic instrument]]
<br>
<br>
<br>
<br>

Latest revision as of 15:27, 3 March 2023


Analyzer acoustic vibration multichannel
FFT analyzers

The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.

We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.

In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB. These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.


Schedule a demo Get a quotation Contact support



Main Features

  • From 2-32 channels
  • Synchronous measurements up to 1000ch is possible by combining multiple analyzers (*)
  • Compact and lightweight (4ch model 1.5kg, 10ch model 3.0kg)
  • Achieves high-speed communication with a PC through an ethernet LAN interface
  • Equipped with an output channel as a standard
  • Built-in internal battery as a standard
  • Record, Fast Fourier Transform analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
  • Realtime measurements and post-analysis can be performed with the same software platform (NVGate)
  • In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS (**)
  • CAN-bus module compatible (***)
  • Recording is possible with analyzer in standalone mode or in conjunction with a PC (****)


(*) Synchronous measurements that combine multiple analyzers is possible only for TW OR35 / TW OR36 / TW OR38.

(**) The strain / temperature module(XPOD) can be installed only on TW OR35 / TW OR36 / TW OR38.

(***) CAN-bus module can be installed only on OR10/ TW OR35 / TW OR36 / TW OR38.

(****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38.

Introducing the hardware

OROS instrument analyzer for noise and vibration

Small and lightweight

OR10-8ch model: 0.8kg

O4: 4ch model: 0.5kg

OR35 TW: 10ch model: 3.0kg

OR36 TW: 16ch model: 5.2kg

OR38 TW: 32ch model: 8.2kg





Ethernet LAN interface

Back of FFT analyzer : ethernet connection for PC

Achieves high-speed communication with a PC through an ethernet LAN interface





Built-in battery

OR10/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.

OR10 can be operated by battery for 4hours

OR35 can be operated by battery for 3 hours.

TW OR36 / TW OR38 can be operated by battery for 2 hours.

04 operate with battery PC.

External battery

External battery on spetrum analyzer

We provide a compact and lightweight external battery that can be installed on all models.

Can be used for up to 8 hours with one external battery.

Can be stored in a "PC integrated carrying case".





Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers

(TW OR35 / TW OR36 / TW OR38 only)

High-precision synchronous measurements (0.2 ° @ 20kHz) are possible by simply connecting each analyzer using a general-purpose LAN cable. Function measurements can be taken with the hammer connected to the third unit in the chain and the accelerometers connected to each unit. Tracking analysis can be completed with the accelerometers connected to each unit while using a tachometer connected to the second unit in the chain.

cascade mode

Measure From Sound / Vibration and Strain Gauge / Temperature

(OR35 / TW OR36 / TW OR38 only)

Temperature and straing conditionner

By mounting a strain gauge conditioner and thermocouple conditioner on the Oros FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.

Thermocouple amplifier: Supports types J, K, T, N, E (with temperature compensation)



CAN-bus Module Available

Can bus to add on OROS instrument

(OR10/ TW OR35 / TW OR36 / TW OR38 only)

By using the CAN-bus module, tracking analysis can be performed using information such as the engine speed flowing from the CAN-bus. By using this function, tracking analysis can be performed without using a tachometer.

Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode

(OR35 / TW OR36 / TW OR38 only)

Vibration time signal Measurement without PC

The FFT analyzer is equipped with a record-only button. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.






In addition, the back of the Fast Fourier Transform Spectrum Analyzer Multipurpose is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors.

all the plug available on the backside of instrment


Software Introduction

  • Easy-to-use interface
  • Real-time measurement / post-analysis can be performed with the same software platform (NVGate)
  • One-click report creation function

Start the Measurement Quickly and Easily

You can start measuring immediately by using the quick function provided in the OROS FFT analyzer mult function. This is completed by defining the number of input channels in the channel field and the measurement/analysis content in the show results area.


The Oros series FFT spectrum analyzer multifunction uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.

NVgate ribbon technology

One-click Setting Function

With the Oros series multi-purpose FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below.


Parameters easy to change

Control Panel

In addition, the OROS FFT spectrum analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the control panel. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.

Control easily the software

Various filters can be applied to recorded signals & FFT analysis results

Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a filter, it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components.

Filter analyzer

Extract arbitrary order components from the color spectrum graph in real time

Any order component can be extracted in real time from the color spectrum graph.

order extraction on vibration software

Easy-to-read Layout

The area for arranging windows is called a layout. The OROS multi function FFT analyzer can create up to 16 layouts per project. You can easily arrange your windows by using the layout function. And your windows will open the same way each time.

It is possible to display up to 32 screens in one layout.

Up to 512 windows (= 16 x 32) can be displayed.


Layout utilization example:


Layout 1: Record waveform, FFT analysis result, order ratio analysis result displayed

Recorder and FFT together


Layout 2: Display 3D frequency analysis results and 3D order ratio analysis results

NVGate software on line measurement



Layout 3: Display 3D octave analyzer analysis results

Acoustic measurement with octave

Easy operation <Graph layout selection button>

You can easily arrange windows just by selecting the grid menu.

Grid icone


Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.

export your data


Data measured at different times can be overwritten by dragging which allows for easily comparing measurement data.

Software NVGate

One-click report creation function

Simply click the report button located on the ribbon interface to create a report file containing the current measurement results.

report all windows

• The content of the report is customizable. Customize it to the format that best suits your needs.

Post analysis vibration software

Measurement data search function

cloud vibration data

Various information (meta-data) can be added when saving measurement data. You then can search for measurement data and projects based on the added information.

Filter:

  • Project name
  • Measurement date and time
  • Measurement conditions
  • Measurement target
  • Measurement site
  • User

Acoustic and vibration search function

Fail judgment function as standard

The pass / fail feature of NVGate can be performed automatically after setting the desired bounds.

In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.

Failed pass test on resonnance frequency test

Automate post-analysis processing

The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours.


Offline measurement

specification

Main specifications

O4 OR10 OR35 OR36 OR38
Dynamical Input channel
Number of analysis channels 2, 4 4, 8 6, 10
(Select Analysis or tachometer on 2 channels)
4, 8, 12, 16 8, 16, 24, 32
Terminal shape BNC Lemo (deliverd with "Lemo to BNC" cable) BNC
Input coupling and sensor support Compatible with AC, DC / ICP (sensor with built-in amplifier) ​​and TEDS
Cutoff frequency -3dB at AC cutoff frequency 0.35Hz
Input voltage range +/-: 100mV to +/-: 40V (auto range function)
Maximum voltage 60V
Anti-Aliasing filter 400dB / OCT
Input impedance 1MΩ <100pF
A / D converter 24-bit
Dynamic range >140dB
Channels-to-channels phase accuracy ± 0.02 ° (10V, 20kHz range)
Input filter Acoustic A, C, Z, low pass, high pass, band pass, integrator, differentiator, time axis integration function
Sampling frequency of the signal Select from 13 ranges between 102.4kHz and 2.048kHz.
Tachometer channel (Ext synch channels)
Number of input channels 2 channels 2 channels (up to 6 channels as an option)
Sampling frequency 6.4MHz (counter method)
Voltage range +/- 300mV 40V
DC input
number of input channels none Analysis channel can be switched and used
Voltage range none 22 bits, ± 40V, offset DC 100μV or less
Samplingfrequency none 15Hz or 12.5Hz
Calibration function
Calibration method Automatic sensitivity calculation by numerical input or reference signal (for position and standard vibration oscillatory meter)
How to use at the time of measurement Select by registered sensor name such as model name and machine number
Trigger function
Trigger type Edge, period, △ RPM, △ level, manual, multi (A or B, A and B, A after B)
Trigger delay Pre- and post-trigger functions
Trigger signal Select from any input channel
Record function
Sampling frequency 13 ranges from 102.4kHz to 2.048kHz possible to select 2 types of range together
A / D converter resolution 24-bit or 16-bit
Hard drive size PC hard drive 64 GB SSD 128 GB removable SSD hard drive (256GB or 512 GB optional)
FFT analysis performance
Analysis frequency range 0.8Hz-100kHz 0.8Hz-40kHz
FFT block size 256, 512, 1024, 2048, 4096, 8192, 1638
Number of analysis lines 101, 201, 401, 801, 1601, 3201, 6401
Zoom analysis 2 to 128 times (all channels at the same time)
Overlap setting 0-99.99%
Window function Flat Top, Hanning, Humming, Kaiser Vessel, Rectangular, Force / Response
Average mode Time, frequency, fdsa / linear, exponential, peak hold
Analysis / display function
Time series Real-time waveform, record waveform, DC, Max, Min, RMS
FFT analysis Linear power spectrum, average spectrum, PSD, cross spectrum,

transfer function (H1, H2), copying function

Display color Display color: Arbitrary specification of trace, cursor, background, and grid display colors
Options:
Time domain analysis (ORNV-TDA)
Analysis items Monitor display for arbitrary time (msec to day), effective value for arbitrary section, Min, Max, Peak,

Peak / Peak, RMS, DC, crest factor, Skew, Kurtosis

1/n octave analysis (ORNV-OCT)
method Digital filter operation on time domain
Analysis band 1/1, 1/3, 1/12, 1/24 octave (IEC1260: 1995 Class 1, ANSI S1.11-1986)
Analysis frequency Simultaneous analysis of all channels at 20kHz is possible (DSP option may be required)
Average Fast, Slow, lmpulse, LEQ, constantBT, linear repeat,exponential
Multi-sound level meter [ORNV-OVA]
Operation method Time series signal digital operation
Acoustic weithing Linear, A, C
Measurement Leq, Fast, Slow, lmpulse, average, Peak, Max, Min
Average Fast, Slow, lmpulse, LEQ, constantBT, linear repeat,exponential
Synchronous Order tracking analysis [ORNV-ORD]
Analysis function Instantaneous and average spectrum,phase, order profile and overall.
Maximum rotation speed 1,200,000 RPM
Max analysis ordersetting 6.25, 12.5, 25, 50, 100, 200, 400
Number of analysis lines 25-800
Analysis bandwidth resampling method and fixed sampling method
display Simultaneous display of 3D display and tracking order, simultaneous display of time signal
Rotational torsion analysis [ORNV-IVC]
Operation method Digital Frequnecy Voltage converter
Number of analysis channels 2ch 2ch (up to 6ch as an option)
Rotation diagnosis function [ORNV-FFTDiag]
Analysis items Envelope analysis, cepstrum, self-cross function, MAX, MIN, peak detection from block data, simulated tach,
Output Channel
Number of output channels 1ch (lemo conector, include) no output 2ch 2ch (up to 6ch as an option)
Output waveform Sinus, step sinus, sweep sinus, chirp, multi-sinus, random (pink and white), DC voltage, record signal Sinus, step sinus, sweep sinus, chirp, multi-sinus, random (pink and white), DC voltage, record signal
Digital / Analogic converter 24 bits 24 bits
Output voltage +/- 10V +/- 10V
Output Inpedence 50 Ω 50 Ω
Frequency range ~ 100kHz ~ 40kHz
Sweep mode Sweep and step, analyze, trigger and sync, linear and log Sweep and step, analyze, trigger and sync, linear and log
Synchronization with the analysis Synchronization and free run Synchronization and free run
Output protection Stabilization with time specification and forced stop button Stabilization with time specification and forced stop buttoz
Data
Image and print Image, printing for Windows and user template creation function for Word and Excel
File TXT, UFF, MATLAB, WAV (OROS and Audio) SDF, binary, ATFX (optional)
Data entry WAV, TXT, UFF and OR20 series AE2
Dimensions / weight
Dimensions (width x height x depth mm) 35 x 110 x 185 37 x 174 x 120 56 × 246 × 222 102 x 260 x 311 102 x 364 x 311
Weight 0.5kg 0.85kg 2.8kg 5.2 kg 8.2 kg
Power supply
AC AC 100V-240V
DC USB 3.0 type C 5V USB 15V 10V-28V, 20VA 10V-28V, 60VA 10V-28V, 100VA
DC battery internal operating time (built-in) NA : using PC battery 4h 3h 2h 2h
Recommended operating temperature range 0 ℃ ~ 40 ℃ 0 ℃ ~ 50 ℃ 0 ℃ ~ 45 ℃
cooling fan Fan less Fan less Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)


PC requirement

Connections Type: Ethernet, Connector: RJ45
Operating systems Windows 7 / Windows 10 / Windows 11
Recommended CPU : Quad core processor (Desktop : Intel Core i3 or Ryzen 3, Laptop : Intel Core i5 or Ryzen 5)

RAM : 6 GB
Storage : SSD, 1 GB free + storage for signals



Function

  • REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Level Meter
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 13.png Waterfall analysis (three-dimensional display)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png Signal record and post analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Resonance frequency by impact hammer
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Vibration on rotordynamics (orbit,...)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Modal Analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Power
  • REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Frequency analysis, spectrum analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Noise / acoustic analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png Time series analysis (data logger)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Vibration of rotating machines
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Customization (ex: automatic measurement)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Quality
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Monitoring

  • Catalog download

    noise and vibration catalog download






    Download











    Applications/ Case study

    Main application and commonly used functions:

    FFT analyzers are used in research and development, quality control, inspection, service departments, etc.

    Improvements in vehicle quietness, ride quality, comfort, maneuverability, etc.

    Automotive noise and vibration


    Responding to quality problems caused by vibration and noise of vehicles and rotating equipment

    rotating machine vibration


    Environmental problems caused by noise from construction machinery, office machines, home appliances, etc.

    Acoutsic and vibration application


    Problems with processing accuracy due to minute vibrations in microscopes, machine tools, semiconductor manufacturing equipment, etc.

    Accuracy measurement


    A collection of application examples using the OROS FFT analyzer OROS series

    Introducing solution examples that can be provided by various functions unique to OROS FFT analyzers.


    • Vibration measurement of cutting machine
    Vibration measurement of cutting machine


    Introducing what approach can be taken using the OROS FFT Analyzer to identify mechanical resonance problems due to changes in cutting conditions.
    Download on my.oros.com (need register)




    • Monitoring of wind power generation equipment and abnormality diagnosis
    Monitoring vibration

    Measuring vibration noise generated from rotating machines (gearboxes, generators, etc.) in wind power generation equipment is indispensable for equipment maintenance and longevity. In addition to the real-time analysis capability of rotating machinery, which is the strength of the OROS FFT analyzer, remote control / monitoring and stand-alone functions can be used to more efficiently diagnose equipment for wind power generation equipment.
    Download on my.oros.com (need to register)

    • Diesel engine camshaft rotational twist measurement
    Diesel engine camshaft rotational twist

    In the prototype of a small diesel engine, there is a problem that the rotational torsional vibration of the timing belt and the camshaft resonates, causing a large vibration. By measuring rotational fluctuations and rotational twists with high accuracy using the six tachometer channels mounted on the OROS FFT analyzer, it is clarified which rotational order is dominant for vibration.

    Download on my.oros.com (need register)



    Some references:

    airplane automotive energy measurement

    Full technical support

    • Hotline dedicated
    expert on noise and vibration

    Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.

    Tel: +33.4.76.90.52.40
    Email: customer.care@oros.com

    Your local distributor

    • User training course

    OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
    Korean vibration camp

    • Worldwide presence and accredited maintenance center

    With a worldwide coverage of distributor network and maintenance center (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
    maintenance center
    Find Your local distributor

    calibration repair metrologic instrument



    Technicians are certified on a regular basis by OROS specialists, enabling them to repair, calibrate and upgrade all OROS systems.


    • Premium contract

    1, 2 or 4 years renewable contracts to extend your warranty.

    • Access to the latest software version.
    • Full coverage on your instrument (calibration and maintenance)
    • Guaranteed turn around time (4 days) for hardware repairs and calibration
    • Privileged access to extended services at a preferential rate: urgent loan within 1 day.

    Video content

    We have released videos such as product introductions and demonstrations.

    Click here for the youtube video content page

    Schedule a demo Get a quotation Contact support