Difference between revisions of "FFT Spectrum Analyzer Multipurpose"

From OROS Wiki
Jump to navigation Jump to search
(116 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{#seo:
|title=FFT Spectrum analyzer for acoustic and vibration - Modal analysis
|keywords= FFT analyzer, vibration analyzer, Spectrum analyzer, analyzer acoustic and vibration, Octave analyzer, third octave, FFT analysis software, order tracking measurement, turbomachinery Orbit, fast fourier transform, modal analysis
|description= OROS portable hardware multichannels Instrument with real time software, easy to operate .
|image=FFT_analyzer_hardware_2.webp
}}
__NOTOC__
__NOTOC__
page under construction
[[File:O4_range Gamme O4 + OR10 + OR35 + OR36 + OR38.png|frame|left|FFT analyzers|alt=Analyzer acoustic vibration multichannel]]
 
[[File:FFT analyzer hardware.jpg|frame|150px|left]]
The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.  
The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.  


We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.  
We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.  


In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB (125 dB for OR34). These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.
In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB. These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.


The OROS series spectrum FFT analyzer multupurpose, boasts higher performance and functionality which allows a user to efficiently calculate the desired measurement result.


{|class="wikitable"  style="width:50%;"  
{|class="wikitable"  style="width:100%;"  
|style="background: #0000A0 ; color:white ; text-align:center;"|<big>[https://www.oros.com/demo-request/ <span style="color:white;">Ask  for a  demo]</big>
|style="background: #0000A0; text-align:center;"|<big>[https://www.oros.com/demo-request/ <span style="color:white;">Schedule a  demo]</big>
|style="background: red; color:white; text-align:center;"|<big>[https://www.oros.com/quote-request-form/ <span style="color:white;"> Ask for a quotation]</big>
|style="background: red; text-align:center;"|<big>[https://www.oros.com/quote-request-form/ <span style="color:white;"> Get a quotation]</big>
|style="background: green; color:white; text-align:center;"|<big>[https://wiki.oros.com/wiki/index.php/Home#Full_technical_support <span style="color:white;"> Ask support hotline]</big>
|style="background: green; text-align:center;"|<big>[[FFT_Spectrum_Analyzer_Multipurpose#Full_technical_support|<span style="color:white;">Contact support]]</big>
|}
|}




<gallery gallery mode="packed-hover" align= left >
<gallery gallery="" mode="packed-hover" align="left">
TWanalyzer2.jpg
File:TWanalyzer2.jpg|alt=Vibration measurement up to 1000 channels|Analyzer Cascade mode
Situation_auto_hammer_pc.jpg
File:Situation auto hammer pc.jpg|alt=Hammer test on automative in anechoic room|Modal FRF measurement
Auto_anechoic_chamber3.jpg
File:Auto anechoic chamber2.webp|alt=Sound intensiyt measurement in anechoic room|Acoustic Sound intensity
turbo orbit.JPG
File:Turbo orbit.JPG|alt=Turbomachinery orbit vibration measurement|Vibration on trubomachinery
Or34_situation.jpg
File:Or34 situation.jpg|alt=NVH measurement on a car|NVH automotive measurement
airfrance.jpg
File:Airfrance.jpg|alt=Acoutic measurement with octave anlyzer in a plane|In flight measurement
</gallery>
</gallery>


Line 38: Line 42:
* Equipped with an output channel as a standard  
* Equipped with an output channel as a standard  
* Built-in internal battery as a standard
* Built-in internal battery as a standard
* Record, FFT analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
* Record, Fast Fourier Transform analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
* Realtime measurements and post-analysis can be performed with the same software platform (NVGate)
* Realtime measurements and post-analysis can be performed with the same software platform ([[NVGate]])
* In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS  (**)
* In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS  (**)
* CAN-bus module compatible (***)
* CAN-bus module compatible (***)
* Recording is possible with only the FFT analyzer in standalone mode or in conjunction with a PC (****)
* Recording is possible with analyzer in standalone mode or in conjunction with a PC (****)




Line 53: Line 57:
(****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38.
(****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38.


=Introducing the hardware=
==Introducing the hardware==
[[File:hardware.png|right|Spectrum analyzer|alt=OROS instrument analyzer for noise and vibration]]
===Small and lightweight===


==Small and lightweight==
[[File:model.jpg|200px|right]]
<br>
<br>


OR10-8ch model: 0.8kg
OR10-8ch model: 0.8kg


4ch model: 1.5kg
O4: 4ch model: 0.5kg


10ch model: 3.0kg
OR35 TW: 10ch model: 3.0kg


16ch model: 5.2kg
OR36 TW: 16ch model: 5.2kg


32ch model: 8.2kg
OR38 TW: 32ch model: 8.2kg
<br>
<br>
<br>
<br>
<br>
<br>
<br>
<br>
<br>


==Ethernet LAN interface==
===Ethernet LAN interface===
[[image:laninterface.PNG|right]]
[[image:laninterface.PNG|right|FFT analyzer ethernet|alt=Back of FFT analyzer : ethernet connection for PC]]
Achieves high-speed communication with a PC through an ethernet LAN interface
Achieves high-speed communication with a PC through an ethernet LAN interface
<br>
<br>
<br>
<br>
<br>
Line 85: Line 88:
<br>
<br>


==Built-in battery==
===Built-in battery===
OR10/ OR34/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.
OR10/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.


OR10 can be operated by battery for 4hours
OR10 can be operated by battery for 4hours
Line 94: Line 97:
TW OR36 / TW OR38 can be operated by battery for 2 hours.
TW OR36 / TW OR38 can be operated by battery for 2 hours.


==External battery==
04 operate with battery PC.
[[File:external battery.PNG|200px|right]]
 
===External battery===
[[File:external battery.PNG|200px|right|external battery on analyzer|alt=External battery on spetrum analyzer]]


We provide a compact and lightweight external battery that can be installed on all models.
We provide a compact and lightweight external battery that can be installed on all models.
Line 111: Line 116:
<br>
<br>


==Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers==
===Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers===
(TW OR35 / TW OR36 / TW OR38 only)
(TW OR35 / TW OR36 / TW OR38 only)


High-precision synchronous measurements (0.2 ° @ 20kHz) are possible by simply connecting each analyzer using a general-purpose LAN cable. Function measurements can be taken with the hammer connected to the third unit in the chain and the accelerometers connected to each unit. Tracking analysis can be completed with the accelerometers connected to each unit while using a tachometer connected to the second unit in the chain.
High-precision synchronous measurements (0.2 ° @ 20kHz) are possible by simply connecting each analyzer using a general-purpose LAN cable. Function measurements can be taken with the hammer connected to the third unit in the chain and the accelerometers connected to each unit. Tracking analysis can be completed with the accelerometers connected to each unit while using a tachometer connected to the second unit in the chain.


[[File:teamworkanalyzer.png|700px]]
[[File:teamworkanalyzer.png|700px|cascade mode]]


== Measure From Sound / Vibration and Strain Gauge / Temperature ==
=== Measure From Sound / Vibration and Strain Gauge / Temperature ===
(OR35 / TW OR36 / TW OR38 only)
(OR35 / TW OR36 / TW OR38 only)
[[File:Usersmanual_32.jpg|200px|right]]
[[File:Usersmanual_32.jpg|200px|right|Conditioner on analyzer|alt=Temperature and straing conditionner]]
By mounting a [[XPod_Bridge_-_Strain_gauge|strain gauge conditioner]] and [[NVGate_X-Pod:_Temperature_probe_conditioner|thermocouple conditioner]] on the OR3X FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.
By mounting a [[XPod_Bridge_-_Strain_gauge|strain gauge conditioner]] and [[NVGate_X-Pod:_Temperature_probe_conditioner|thermocouple conditioner]] on the Oros FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.


Thermocouple amplifier: Supports types J, K, T, N, E (with temperature compensation)
Thermocouple amplifier: Supports types J, K, T, N, E (with temperature compensation)
Line 129: Line 134:
<br>
<br>


==CAN-bus Module Available ==
===CAN-bus Module Available ===
[[File:Can_Bus.jpg|150px|right]]
[[File:Can_Bus.jpg|150px|right|Can bus measurement|alt=Can bus to add on OROS instrument]]
(OR10/ TW OR35 / TW OR36 / TW OR38 only)
(OR10/ TW OR35 / TW OR36 / TW OR38 only)


Line 137: Line 142:
<br>
<br>


==Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode ==
===Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode ===
(OR35 / TW OR36 / TW OR38 only)
(OR35 / TW OR36 / TW OR38 only)


[[File:d_rec.PNG|150px|right]]
[[File:d_rec.PNG|150px|right|Data acquisition recorder|alt=Vibration time signal Measurement without PC]]
The FFT analyzer is equipped with a [[NVGate_D-Rec|record-only button]]. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.
The FFT analyzer is equipped with a [[NVGate_D-Rec|record-only button]]. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.


Line 149: Line 154:




In addition, the back of the FFT analyzer is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors. 


[[File:FFT_analyzer.jpg|600px]]
In addition, the back of the Fast Fourier Transform Spectrum Analyzer Multipurpose is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors. 
 
[[File:FFT_analyzer.jpg|600px|Back of the hardware|alt=all the plug available on the backside of instrment]]
<br>
<br>
<br>
<br>
<br>
<br>


=Software Introduction=
==Software Introduction==


*Easy-to-use interface
*Easy-to-use interface
Line 162: Line 168:
*One-click report creation function
*One-click report creation function


==Start the Measurement Quickly and Easily==
===Start the Measurement Quickly and Easily===




Line 169: Line 175:




The OR3X series multi-job FFT analyzer uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.
The Oros series FFT spectrum analyzer multifunction uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.


[[File:home3.PNG|800px]]
[[File:home3.PNG|800px|software ribbon|alt=NVgate ribbon technology]]


==One-click Setting Function==
===One-click Setting Function===
With the OR3X series multi-job FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below.
With the Oros series multi-purpose FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below.




[[File:FFT_analyzer_spectrum.png|500px]]
[[File:FFT_analyzer_spectrum.png|500px|FFT spectrum|alt=Parameters easy to change]]


==Control Panel==
===Control Panel===
In addition, the OR3X series multi-job FFT analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the [[NVGate_Control_Panel|control panel]]. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.
In addition, the OROS FFT spectrum analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the [[NVGate_Control_Panel|control panel]]. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.


[[File:control pannel_test.png|700px]]
[[File:control pannel_test.png|700px|Software FFT settings|alt=Control easily the software]]


==Various filters can be applied to recorded signals & FFT analysis results==
===Various filters can be applied to recorded signals & FFT analysis results===
Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a [[NVGate_Filter_Builder|filter]], it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components.
Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a [[NVGate_Filter_Builder|filter]], it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components.


[[File:filter_fft.png|600px]]
[[File:filter_fft.png|600px|Filter analyzer]]


==Extract arbitrary order components from the color spectrum graph in real time==
===Extract arbitrary order components from the color spectrum graph in real time===


Any order component can be extracted in real time from the color spectrum graph.
Any order component can be extracted in real time from the color spectrum graph.


[[File:extraction.jpg]]
[[File:extraction.jpg|Synchronous order analysis extraction|alt=order extraction on vibration software]]


Easy-to-read Layout
Easy-to-read Layout
Line 210: Line 216:
'''Layout 1''': Record waveform, FFT analysis result, order ratio analysis result displayed
'''Layout 1''': Record waveform, FFT analysis result, order ratio analysis result displayed


[[File:Fft_extraction.PNG]]
[[File:Fft_extraction_data.jpg|Order extraction|alt=Recorder and FFT together]]




'''Layout 2''': Display 3D frequency analysis results and 3D order ratio analysis results
'''Layout 2''': Display 3D frequency analysis results and 3D order ratio analysis results


[[File:waterfall_extract_order.jpg]]
[[File:waterfall_extract_order.jpg|3d display order spectrum |alt=NVGate software on line measurement]]








'''Layout 3''': Display 3D octave analysis results
'''Layout 3''': Display 3D '''octave analyzer''' analysis results


[[File:octave waterfall.jpg]]
[[File:octave waterfall.jpg|Octave acoustic measurement 3d display|alt=Acoustic measurement with octave]]


==Easy operation <Graph layout selection button>==
===Easy operation <Graph layout selection button>===




You can easily arrange windows just by selecting the grid menu.
You can easily arrange windows just by selecting the grid menu.


[[File:gridwindows_PNG.PNG]]
[[File:gridwindows_PNG.PNG|NVGate icone|alt=Grid icone]]




Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.
Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.


[[File:excel_report.jpg|400px]]
[[File:excel_report.jpg|400px|FFT spectrum Report function|alt=export your data]]




Data measured at different times can be overwritten by dragging which allows for easily comparing measurement data.
Data measured at different times can be overwritten by dragging which allows for easily comparing measurement data.


[[File:drag_drop_report.jpg]]
[[File:drag_drop_report.jpg|Software NVGate]]


==One-click report creation function==
===One-click report creation function===




Simply click the report button located on the ribbon interface to create a [[NVGate_Report|report]] file containing the current measurement results.
Simply click the report button located on the ribbon interface to create a [[NVGate_Report|report]] file containing the current measurement results.


[[File:allwindows_.PNG]]
[[File:allwindows_.PNG|NVGate report|alt=report all windows]]


• The content of the report is customizable. Customize it to the format that best suits your needs.
• The content of the report is customizable. Customize it to the format that best suits your needs.


[[File:report-customize.jpg|500px]]
[[File:report-customize.jpg|500px|customize FFT analyzer software report|alt=Post analysis vibration software]]


==Measurement data search function==
===Measurement data search function===
[[File:pc cloud.PNG|right]]
[[File:pc cloud.PNG|right|Data stored|alt=cloud vibration data]]
Various information (meta-data) can be added when saving measurement data.
Various information (meta-data) can be added when saving measurement data.
You then can search for measurement data and projects based on the added information.  
You then can search for measurement data and projects based on the added information.  
Line 264: Line 270:
* Measurement site  
* Measurement site  
* User
* User
[[File:filter_project.PNG|550px]]
[[File:filter_project.PNG|550px|meta data on noise and vibration software NVGate|alt=Acoustic and vibration search function]]


https://www.youtube.com/watch?v=kx2HbcvfG_w==Equipped with Pass / Fail judgment function as standard==
===Fail judgment function as standard===
The pass / fail feature of NVGate can be performed automatically after setting the desired bounds.  
The [https://youtu.be/kx2HbcvfG_w pass / fail feature] of NVGate can be performed automatically after setting the desired bounds.  


In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.
In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.


[[File:gonogo_test.jpg]]
[[File:fail_test.JPG|Pass/fail test on resonnance frequency impact hammer test|alt=Failed pass test on resonnance frequency test]]


==Automate post-analysis processing==
===Automate post-analysis processing===


The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours.
The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours.




[[File:BPP2.jpg]]
[[File:BPP2.jpg|Post processing acoustic measurement batch |alt=Offline measurement]]


==specification==
==specification==
Line 285: Line 291:
{| class=wikitable style="width:100%;" style="text-align:center;"
{| class=wikitable style="width:100%;" style="text-align:center;"
! style="width:15%|
! style="width:15%|
! style="width:17%|OR34
! style="width:17%|O4
! style="width:17%|OR10
! style="width:17%|OR10
! style="width:17%|OR35
! style="width:17%|OR35
Line 294: Line 300:
|-
|-
! Number of analysis channels  
! Number of analysis channels  
| 2,4  
| 2, 4  
| 4,8
| 4, 8
| 4,8
| 6, 10 <br>  (Select Analysis or tachometer on 2 channels)
| 4,8,12,16
| 4, 8, 12, 16
| 8, 16, 24, 32
| 8, 16, 24, 32
|-
|-
! Terminal shape
! Terminal shape
| colspan=1| BNC
| colspan=1| BNC
| colspan=1| Lemo (deliverd with Lemo to BNC cable)
| colspan=1| Lemo (deliverd with "Lemo to BNC" cable)
| colspan=3| BNC
| colspan=3| BNC
|-
|-
Line 312: Line 318:
|-
|-
! Input voltage range
! Input voltage range
| +/- : 17.5mV - 10V with auto range function
|colspan=5| +/-: 100mV to +/-: 40V (auto range function)
|colspan=4| +/-: 100mV - 40V with auto range function
|-
|-
! Maximum voltage
! Maximum voltage
| 40V
|colspan=5| 60V
|colspan=4| 60V
|-
|-
!Anti-Aliasing filter  
!Anti-Aliasing filter  
Line 329: Line 333:
|-
|-
!Dynamic range
!Dynamic range
|colspan=5| ± 0.05dB (1kHz
|colspan=5| >140dB
|-
|-
!Channels-to-channels phase accuracy
!Channels-to-channels phase accuracy
|colspan=5| ± 0.02 ° (10V, 20kHz range
|colspan=5| ± 0.02 ° (10V, 20kHz range)
|-
|-
!Input filter
!Input filter
|colspan=5| Acoustic A, C r, low pass, high pass, band pass, integrator, differentiator, time axis integration function
|colspan=5| Acoustic A, C, Z, low pass, high pass, band pass, integrator, differentiator, time axis integration function
|-
|-
!Sampling frequency of the signal
!Sampling frequency of the signal
Line 350: Line 354:
|-
|-
!Voltage range
!Voltage range
|colspan=1|+/- 300mV  10V
|colspan54|+/- 300mV  40V
|colspan=4|+/- 300mV  40V
|-
|-
!colspan=6| DC input
!colspan=6| DC input
Line 402: Line 405:
|-
|-
!Analysis frequency range
!Analysis frequency range
|colspan=5|0.8Hz-40kHz
|colspan=1|0.8Hz-100kHz
|colspan=4|0.8Hz-40kHz
|-
|-
!FFT block size
!FFT block size
Line 519: Line 523:
|-
|-
!Number of output channels
!Number of output channels
|colspan=1| 1ch
|colspan=1| 1ch (lemo conector, include)
|colspan=1| no output
|colspan=1| no output
|colspan=1| 2ch
|colspan=1| 2ch
Line 547: Line 551:
|-
|-
!Frequency range
!Frequency range
|colspan=1|~ 40kHz
|colspan=1|~ 100kHz
|colspan=1|
|colspan=1|
|colspan=3|~ 40kHz
|colspan=3|~ 40kHz
Line 583: Line 587:
|-
|-
!Dimensions (width x height x depth mm)
!Dimensions (width x height x depth mm)
|45 x 205 x 154
|35 x 110 x 185
|37 x 174 x 120
|37 x 174 x 120
|56 × 246 × 222
|56 × 246 × 222
Line 590: Line 594:
|-
|-
!Weight
!Weight
| 1.5kg
| 0.5kg
| 0.85kg
| 0.85kg
| 2.8kg
| 2.8kg
Line 602: Line 606:
|-
|-
!DC  
!DC  
| 10V-28V, 15VA
| USB 3.0 type C 5V
| USB 15V
| USB 15V
| 10V-28V, 20VA
| 10V-28V, 20VA
Line 609: Line 613:
|-
|-
!DC battery internal operating time (built-in)  
!DC battery internal operating time (built-in)  
| 15 minutes
| NA : using PC battery
| 4h
| 4h
| 3h
| 3h
Line 616: Line 620:
|-
|-
!Recommended operating temperature range
!Recommended operating temperature range
|colspan=4| 0 ℃ ~ 50 ℃
|colspan=3| 0 ℃ ~ 40 ℃
|colspan=3| 0 ℃ ~ 50 ℃
|0 ℃ ~ 45 ℃
|0 ℃ ~ 45 ℃
|-
|-
!cooling fan
!cooling fan
|colspan=1|Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)
|colspan=1|Fan less
|colspan=1|Fan less
|colspan=1|Fan less
|colspan=4|Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)
|colspan=4|Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)
Line 642: Line 647:
'''RAM : 6 GB'''<br>
'''RAM : 6 GB'''<br>
'''Storage : SSD''', 1 GB free <nowiki>+</nowiki> storage for signals
'''Storage : SSD''', 1 GB free <nowiki>+</nowiki> storage for signals
|-
!Minimum
|'''CPU : Quad core processor''' (Desktop : Intel Core i3 or Ryzen 3, Laptop : Intel Core i5 or Ryzen 5)<br>
'''RAM : 4 GB'''<br>
'''GPU : VRAM 1 GB''', 1024 x 768 display<br>
'''Storage : HDD''', 1 GB<nowiki>+</nowiki> storage for signals
|}
|}


Line 653: Line 652:
<br>
<br>


=Function=
==Function==




Line 665: Line 664:
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_Recorder|Signal record and post analysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_Recorder|Signal record and post analysis]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT_Analyzer|Resonance frequency measurement by vibration]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT|Resonance frequency by impact hammer]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[ORBIGate|Vibration and rotordynamics]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[ORBIGate|Vibration on rotordynamics (orbit,...)]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Modal|Modal Anlysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Modal|Modal Analysis]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Power|Sound Power]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Power|Sound Power]]
Line 678: Line 677:
{| class="wikitable"  
{| class="wikitable"  
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT_Analyzer|Frequency analysis, spectrum analysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_FFT|Frequency analysis, spectrum analysis]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Octave_Analyzer|Noise / acoustic analysis]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Octave_Analyzer|Noise / acoustic analysis]]
Line 684: Line 683:
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_D-Rec|Time series analysis (data logger)]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png]] [[NVGate_D-Rec|Time series analysis (data logger)]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Synchronous_Order_Analysis|Vibration / noise analysis of rotating machines]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Synchronous_Order_Analysis|Vibration of rotating machines]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Ribbons:_Automation|Customization such as automatic measurement]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]] [[NVGate_Ribbons:_Automation|Customization (ex: automatic measurement)]]
|-
|-
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Quality_Lite|Sound Quality]]
| [[File:REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png]]  [[Sound_Quality_Lite|Sound Quality]]
Line 695: Line 694:




==Catalog download==
===Catalog download===
[[File:download_brochure.jpg|left|250px]]
[[File:download_brochure.jpg|left|250px|noise and vibration catalog download]]
<br>
<br>
<br>
<br>
Line 704: Line 703:


[https://www.oros.com/wp-content/uploads/2020/08/m002-103-10_oros_range_brochure.pdf Download]
[https://www.oros.com/wp-content/uploads/2020/08/m002-103-10_oros_range_brochure.pdf Download]
<br>
<br>
<br>
<br>
<br>
<br>
Line 715: Line 716:
<br>
<br>


==Applications/ Case study==
===Applications/ Case study===




Line 724: Line 725:
'''Improvements in vehicle quietness, ride quality, comfort, maneuverability, etc.'''
'''Improvements in vehicle quietness, ride quality, comfort, maneuverability, etc.'''


[[File:car_NVH.PNG|right]]
[[File:car_NVH.PNG|right|Automotive noise and vibration]]


* [https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
* [https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
Line 734: Line 735:
'''Responding to quality problems caused by vibration and noise of vehicles and rotating equipment'''
'''Responding to quality problems caused by vibration and noise of vehicles and rotating equipment'''


[[File:rotating.PNG|right]]
[[File:rotating.PNG|right|rotating machine vibration]]


*[https://www.oros.com/solutions/acoustics/sound-level-meter/ Overall measurement]
*[https://www.oros.com/solutions/acoustics/sound-level-meter/ Overall measurement]
Line 746: Line 747:
'''Environmental problems caused by noise from construction machinery, office machines, home appliances, etc.'''
'''Environmental problems caused by noise from construction machinery, office machines, home appliances, etc.'''


[[File:machinery.PNG|right]]
[[File:machinery.PNG|right|Acoutsic and vibration application]]
*[https://www.oros.com/solutions/acoustics/sound-level-meter/ Overall measurement]
*[https://www.oros.com/solutions/acoustics/sound-level-meter/ Overall measurement]
*[https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
*[https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
Line 754: Line 755:
'''Problems with processing accuracy due to minute vibrations in microscopes, machine tools, semiconductor manufacturing equipment, etc'''.
'''Problems with processing accuracy due to minute vibrations in microscopes, machine tools, semiconductor manufacturing equipment, etc'''.


[[File:accuracy.PNG|right]]
[[File:accuracy.PNG|right| Accuracy measurement]]
*[https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
*[https://www.oros.com/solutions/data-acquisition-and-signal-processing/narrow-band-spectral-analysis/ Frequency analysis]
*[https://www.oros.com/solutions/structural-dynamics/frequency-response-function-frf-acquisitions/ Resonance frequency measurement by vibration]
*[https://www.oros.com/solutions/structural-dynamics/frequency-response-function-frf-acquisitions/ Resonance frequency measurement by vibration]
*[https://www.oros.com/solutions/structural-dynamics/modal-analysis/ Experimental mode analysis]
*[https://www.oros.com/solutions/structural-dynamics/modal-analysis/ Experimental modal analysis]




'''A collection of application examples using the OROS FFT analyzer OR3X series'''
'''A collection of application examples using the OROS FFT analyzer OROS series'''


Introducing solution examples that can be provided by various functions unique to OROS FFT analyzer OR3X series.
Introducing solution examples that can be provided by various functions unique to OROS FFT analyzers.




*'''Vibration measurement of cutting machine'''
*'''Vibration measurement of cutting machine'''


[[File:cutting tools machine.jpg|150px|left]]
[[File:cutting tools machine.jpg|150px|left|Vibration measurement of cutting machine]]




Introducing what approach can be taken using the OROS FFT Analyzer OR3X series to identify mechanical resonance problems due to changes in cutting conditions.
Introducing what approach can be taken using the OROS FFT Analyzer to identify mechanical resonance problems due to changes in cutting conditions.
<br>
<br>
[https://my.oros.com/categories/application-notes/ Download on my.oros.com (need register)]
[https://my.oros.com/categories/application-notes/ Download on my.oros.com (need register)]
Line 781: Line 782:
*'''Monitoring of wind power generation equipment and abnormality diagnosis'''  
*'''Monitoring of wind power generation equipment and abnormality diagnosis'''  


[[File:eolienne.PNG|left]]
[[File:eolienne.PNG|left|Monitoring vibration]]


Measuring vibration noise generated from rotating machines (gearboxes, generators, etc.) in wind power generation equipment is indispensable for equipment maintenance and longevity. In addition to the real-time analysis capability of rotating machinery, which is the strength of the OROS FFT analyzer OR3X series, remote control / monitoring and stand-alone functions can be used to more efficiently diagnose equipment for wind power generation equipment.
Measuring vibration noise generated from rotating machines (gearboxes, generators, etc.) in wind power generation equipment is indispensable for equipment maintenance and longevity. In addition to the real-time analysis capability of rotating machinery, which is the strength of the OROS FFT analyzer, remote control / monitoring and stand-alone functions can be used to more efficiently diagnose equipment for wind power generation equipment.
<br>
<br>
[https://my.oros.com/categories/application-notes/ Download on my.oros.com (need to register)]
[https://my.oros.com/categories/application-notes/ Download on my.oros.com (need to register)]
Line 790: Line 791:


*'''Diesel engine camshaft rotational twist measurement'''  
*'''Diesel engine camshaft rotational twist measurement'''  
[[File:danielson torsionnal.PNG|left]]
[[File:danielson torsionnal.PNG|left|Diesel engine camshaft rotational twist]]


In the prototype of a small diesel engine, there is a problem that the rotational torsional vibration of the timing belt and the camshaft resonates, causing a large vibration. By measuring rotational fluctuations and rotational twists with high accuracy using the six tachometer channels mounted on the OROS FFT analyzer OR3X series, it is clarified which rotational order is dominant for vibration.<br>
In the prototype of a small diesel engine, there is a problem that the rotational torsional vibration of the timing belt and the camshaft resonates, causing a large vibration. By measuring rotational fluctuations and rotational twists with high accuracy using the six tachometer channels mounted on the OROS FFT analyzer, it is clarified which rotational order is dominant for vibration.<br>
<br>
<br>
[https://my.oros.com/categories/application-notes/ Download on my.oros.com (need register)]
[https://my.oros.com/categories/application-notes/ Download on my.oros.com (need register)]
Line 799: Line 800:
*'''Much more Application note on [https://my.oros.com/ my.oros.com]'''
*'''Much more Application note on [https://my.oros.com/ my.oros.com]'''


<gallery gallery mode="packed-hover" align= left>
<gallery gallery="" mode="packed-hover" align="left">
File:end of line turbine test.jpg
File:End of line turbine test.jpg|alt=Gear box measurement with accelerometers|Allen Gears: gear box rotating vibration
File:in flisght helicopter vibration measurement.PNG
File:In flisght helicopter vibration measurement.PNG|alt=motor vibration order extraction|Conrad: On helicopter vibration measurement
File:mecalac sound power.jpg
File:Mecalac sound power.jpg|alt=Octave and sound level meter with microphone|Mecalac: Sound power acoustic measurement
File:In-porsche.JPG
File:In-porsche.JPG|alt=Automotive octave waterfall analyzer with order extraction|Porsche: acoustic sound quality measurement
File:sound power2.jpg
File:Sound power2.jpg|alt=Acoustic room with microphone |Bosch: Sound power acoustic measurement on anechoic chamber
File:vibration on block press.jpg
File:Vibration on block press.jpg|alt=Shock test measurement|IFF Weimar: Vibration on block press
File:blade vibration.jpg
File:Blade vibration.jpg|alt=Spectrum analyzer on the field|Blade vibration
File:elevator shaft vibration.jpg
File:Elevator shaft vibration.jpg|alt=accelerometer and microphone analysis|Sicor: Elevator motor vibration
File:dBVib_01.JPG
File:DBVib 01.JPG|alt=Orbit shaft center line and fluid film bearing vibration|dBVib: On site measurement on turbomachinery
File:equilibrage 005.jpg
File:Equilibrage 005.jpg|alt=Acceleromters on each side of the plan|BSCA: Vibration balancing test
File:washingmachine.jpg
File:Washingmachine.jpg|alt=Bump test geometry with modal software|Washing macine FRF resonnance frequnecy test
File:master_at_work.jpg
File:Master at work.jpg|alt=team watching overall value of accelerometer|Vibration measurement
File:windturbine.jpg
File:Windturbine.jpg|alt=Motor of wind turbine analysis|GDF SUEZ: Windturbine monitoring measurement
File:3 OR38.JPG
File:3 OR38.JPG|alt=multichannel analyzer portable  |3 analyzers working together
File:turbine.JPG
File:Turbine.JPG|alt=hydro vibration measurement|Alstom: Measurement on turbine
</gallery>
</gallery>


Line 822: Line 823:
'''Some references:'''
'''Some references:'''


[[File:reference.PNG|800px]]
[[File:reference.PNG|800px|Analyzer reference|alt=airplane automotive energy measurement]]


==Full technical support==
===Full technical support===




* '''Hotline dedicated'''
* '''Hotline dedicated'''


[[File:Custcare team2 web-1.jpg|OROS Customer Care Team|right|150px|left]]
[[File:Custcare team2 web-1.jpg|right|150px|support FFT analyzer|alt=expert on noise and vibration]]
Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.
Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.


Line 841: Line 842:
OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
<br>
<br>
[[File:user_day.jpg]]
[[File:user_day.jpg|Acoutsic and vibration training|alt=Korean vibration camp]]
<br>
<br>
<br>
<br>
Line 847: Line 848:
* '''Worldwide presence and accredited maintenance center'''
* '''Worldwide presence and accredited maintenance center'''


With a worldwide coverage (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
With a worldwide coverage of distributor network and maintenance center (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
<br>
<br>
[File:woldwilde_presence.jpg|300px]
[[File:map_world_distributor.JPG|Spectrum analyzer worldwild seller|alt=maintenance center]]<br>
[https://www.oros.com/find-us/ Find Your local distributor]
[https://www.oros.com/find-us/ Find Your local distributor]
[[File:repair.jpg|200px|right]]
[[File:repair.jpg|200px|right|repair hardware analyzer|alt=calibration repair metrologic instrument]]
<br>
<br>
<br>
<br>
Line 860: Line 861:
*'''Premium contract'''
*'''Premium contract'''


1, 2 or 4 years renewable contracts to extend your warranty.
1, 2 or 4 years renewable [https://www.oros.com/services/contracts/ contracts] to extend your warranty.


* Access to the latest software version.
* Access to the latest software version.
Line 867: Line 868:
* Privileged access to extended services at a preferential rate: urgent loan within 1 day.
* Privileged access to extended services at a preferential rate: urgent loan within 1 day.


==Video content ==
===Video content ===
'''Video content'''


We have released videos such as product introductions and demonstrations.
We have released videos such as product introductions and demonstrations.
Line 875: Line 875:
<br>
<br>


 
{|class="wikitable"  style="width:100%;"  
 
|style="background: #0000A0; text-align:center;"|<big>[https://www.oros.com/demo-request/ <span style="color:white;">Schedule a  demo]</big>
{|class="wikitable"  style="width:50%;"  
|style="background: red; text-align:center;"|<big>[https://www.oros.com/quote-request-form/ <span style="color:white;"> Get a quotation]</big>
|style="background: #0000A0 ; color:white ; text-align:center;"|<big>[https://www.oros.com/demo-request/ <span style="color:white;">Ask  for a  demo]</big>
|style="background: green; text-align:center;"|<big>[[FFT_Spectrum_Analyzer_Multipurpose#Full_technical_support|<span style="color:white;">Contact support]]</big>
|style="background: red; color:white; text-align:center;"|<big>[https://www.oros.com/quote-request-form/ <span style="color:white;"> Ask for a quotation]</big>
|}
|}

Revision as of 15:27, 3 March 2023


Analyzer acoustic vibration multichannel
FFT analyzers

The OROS series multi-function FFT analyzer is PC-based, high-performance, high reliability and easy to operate.

We have further increased the arithmetic processing speed and increased the real-time analysis capacity to more than 16 times that of the conventional model (OR20 series). An ethernet LAN cable is used as the interface.

In addition, the number of simultaneous recording channels in the frequency range (40 kHz) has been expanded to a maximum of 1000 channels and the dynamic range has been improved to 140 dB. These improvements allow a user to measure time signals over a wide frequency range simultaneously on multiple channels.


Schedule a demo Get a quotation Contact support



Main Features

  • From 2-32 channels
  • Synchronous measurements up to 1000ch is possible by combining multiple analyzers (*)
  • Compact and lightweight (4ch model 1.5kg, 10ch model 3.0kg)
  • Achieves high-speed communication with a PC through an ethernet LAN interface
  • Equipped with an output channel as a standard
  • Built-in internal battery as a standard
  • Record, Fast Fourier Transform analysis, octave analysis, and tracking analysis can be performed simultaneously at high sampling frequencies
  • Realtime measurements and post-analysis can be performed with the same software platform (NVGate)
  • In addition to sound and vibration, strain and temperature can be measured at the same time using XPODS (**)
  • CAN-bus module compatible (***)
  • Recording is possible with analyzer in standalone mode or in conjunction with a PC (****)


(*) Synchronous measurements that combine multiple analyzers is possible only for TW OR35 / TW OR36 / TW OR38.

(**) The strain / temperature module(XPOD) can be installed only on TW OR35 / TW OR36 / TW OR38.

(***) CAN-bus module can be installed only on OR10/ TW OR35 / TW OR36 / TW OR38.

(****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38.

Introducing the hardware

OROS instrument analyzer for noise and vibration

Small and lightweight

OR10-8ch model: 0.8kg

O4: 4ch model: 0.5kg

OR35 TW: 10ch model: 3.0kg

OR36 TW: 16ch model: 5.2kg

OR38 TW: 32ch model: 8.2kg





Ethernet LAN interface

Back of FFT analyzer : ethernet connection for PC

Achieves high-speed communication with a PC through an ethernet LAN interface





Built-in battery

OR10/ OR35/ TW OR36 / TW OR38: Models have a built-in battery.

OR10 can be operated by battery for 4hours

OR35 can be operated by battery for 3 hours.

TW OR36 / TW OR38 can be operated by battery for 2 hours.

04 operate with battery PC.

External battery

External battery on spetrum analyzer

We provide a compact and lightweight external battery that can be installed on all models.

Can be used for up to 8 hours with one external battery.

Can be stored in a "PC integrated carrying case".





Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers

(TW OR35 / TW OR36 / TW OR38 only)

High-precision synchronous measurements (0.2 ° @ 20kHz) are possible by simply connecting each analyzer using a general-purpose LAN cable. Function measurements can be taken with the hammer connected to the third unit in the chain and the accelerometers connected to each unit. Tracking analysis can be completed with the accelerometers connected to each unit while using a tachometer connected to the second unit in the chain.

cascade mode

Measure From Sound / Vibration and Strain Gauge / Temperature

(OR35 / TW OR36 / TW OR38 only)

Temperature and straing conditionner

By mounting a strain gauge conditioner and thermocouple conditioner on the Oros FFT analyzer, it is possible to measure strain and temperature data in addition to sound and vibration data.

Thermocouple amplifier: Supports types J, K, T, N, E (with temperature compensation)



CAN-bus Module Available

Can bus to add on OROS instrument

(OR10/ TW OR35 / TW OR36 / TW OR38 only)

By using the CAN-bus module, tracking analysis can be performed using information such as the engine speed flowing from the CAN-bus. By using this function, tracking analysis can be performed without using a tachometer.

Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode

(OR35 / TW OR36 / TW OR38 only)

Vibration time signal Measurement without PC

The FFT analyzer is equipped with a record-only button. Simply select a predefined measurement setup and press the record button to record onto the FFT analyzer alone without the use of a PC.






In addition, the back of the Fast Fourier Transform Spectrum Analyzer Multipurpose is equipped with an audio terminal and power supply. It is possible to record audio data while also measuring the time signal. The analyzer also can supply power to required sensors, such as proximity probes, tachometers and DC sensors.

all the plug available on the backside of instrment


Software Introduction

  • Easy-to-use interface
  • Real-time measurement / post-analysis can be performed with the same software platform (NVGate)
  • One-click report creation function

Start the Measurement Quickly and Easily

You can start measuring immediately by using the quick function provided in the OROS FFT analyzer mult function. This is completed by defining the number of input channels in the channel field and the measurement/analysis content in the show results area.


The Oros series FFT spectrum analyzer multifunction uses an interface similar to the ribbon interface used by Microsoft Office. All menus are accessible via the ribbon interface, making it easy to change measurement settings.

NVgate ribbon technology

One-click Setting Function

With the Oros series multi-purpose FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below.


Parameters easy to change

Control Panel

In addition, the OROS FFT spectrum analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the control panel. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel.

Control easily the software

Various filters can be applied to recorded signals & FFT analysis results

Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a filter, it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components.

Filter analyzer

Extract arbitrary order components from the color spectrum graph in real time

Any order component can be extracted in real time from the color spectrum graph.

order extraction on vibration software

Easy-to-read Layout

The area for arranging windows is called a layout. The OROS multi function FFT analyzer can create up to 16 layouts per project. You can easily arrange your windows by using the layout function. And your windows will open the same way each time.

It is possible to display up to 32 screens in one layout.

Up to 512 windows (= 16 x 32) can be displayed.


Layout utilization example:


Layout 1: Record waveform, FFT analysis result, order ratio analysis result displayed

Recorder and FFT together


Layout 2: Display 3D frequency analysis results and 3D order ratio analysis results

NVGate software on line measurement



Layout 3: Display 3D octave analyzer analysis results

Acoustic measurement with octave

Easy operation <Graph layout selection button>

You can easily arrange windows just by selecting the grid menu.

Grid icone


Batch copy of measurement data with one menu. Numerical data can be transferred to Excel all at once.

export your data


Data measured at different times can be overwritten by dragging which allows for easily comparing measurement data.

Software NVGate

One-click report creation function

Simply click the report button located on the ribbon interface to create a report file containing the current measurement results.

report all windows

• The content of the report is customizable. Customize it to the format that best suits your needs.

Post analysis vibration software

Measurement data search function

cloud vibration data

Various information (meta-data) can be added when saving measurement data. You then can search for measurement data and projects based on the added information.

Filter:

  • Project name
  • Measurement date and time
  • Measurement conditions
  • Measurement target
  • Measurement site
  • User

Acoustic and vibration search function

Fail judgment function as standard

The pass / fail feature of NVGate can be performed automatically after setting the desired bounds.

In the example below, a dialog is displayed when the product fails, but it is also possible to output a contact signal instead of the dialog.

Failed pass test on resonnance frequency test

Automate post-analysis processing

The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours.


Offline measurement

specification

Main specifications

O4 OR10 OR35 OR36 OR38
Dynamical Input channel
Number of analysis channels 2, 4 4, 8 6, 10
(Select Analysis or tachometer on 2 channels)
4, 8, 12, 16 8, 16, 24, 32
Terminal shape BNC Lemo (deliverd with "Lemo to BNC" cable) BNC
Input coupling and sensor support Compatible with AC, DC / ICP (sensor with built-in amplifier) ​​and TEDS
Cutoff frequency -3dB at AC cutoff frequency 0.35Hz
Input voltage range +/-: 100mV to +/-: 40V (auto range function)
Maximum voltage 60V
Anti-Aliasing filter 400dB / OCT
Input impedance 1MΩ <100pF
A / D converter 24-bit
Dynamic range >140dB
Channels-to-channels phase accuracy ± 0.02 ° (10V, 20kHz range)
Input filter Acoustic A, C, Z, low pass, high pass, band pass, integrator, differentiator, time axis integration function
Sampling frequency of the signal Select from 13 ranges between 102.4kHz and 2.048kHz.
Tachometer channel (Ext synch channels)
Number of input channels 2 channels 2 channels (up to 6 channels as an option)
Sampling frequency 6.4MHz (counter method)
Voltage range +/- 300mV 40V
DC input
number of input channels none Analysis channel can be switched and used
Voltage range none 22 bits, ± 40V, offset DC 100μV or less
Samplingfrequency none 15Hz or 12.5Hz
Calibration function
Calibration method Automatic sensitivity calculation by numerical input or reference signal (for position and standard vibration oscillatory meter)
How to use at the time of measurement Select by registered sensor name such as model name and machine number
Trigger function
Trigger type Edge, period, △ RPM, △ level, manual, multi (A or B, A and B, A after B)
Trigger delay Pre- and post-trigger functions
Trigger signal Select from any input channel
Record function
Sampling frequency 13 ranges from 102.4kHz to 2.048kHz possible to select 2 types of range together
A / D converter resolution 24-bit or 16-bit
Hard drive size PC hard drive 64 GB SSD 128 GB removable SSD hard drive (256GB or 512 GB optional)
FFT analysis performance
Analysis frequency range 0.8Hz-100kHz 0.8Hz-40kHz
FFT block size 256, 512, 1024, 2048, 4096, 8192, 1638
Number of analysis lines 101, 201, 401, 801, 1601, 3201, 6401
Zoom analysis 2 to 128 times (all channels at the same time)
Overlap setting 0-99.99%
Window function Flat Top, Hanning, Humming, Kaiser Vessel, Rectangular, Force / Response
Average mode Time, frequency, fdsa / linear, exponential, peak hold
Analysis / display function
Time series Real-time waveform, record waveform, DC, Max, Min, RMS
FFT analysis Linear power spectrum, average spectrum, PSD, cross spectrum,

transfer function (H1, H2), copying function

Display color Display color: Arbitrary specification of trace, cursor, background, and grid display colors
Options:
Time domain analysis (ORNV-TDA)
Analysis items Monitor display for arbitrary time (msec to day), effective value for arbitrary section, Min, Max, Peak,

Peak / Peak, RMS, DC, crest factor, Skew, Kurtosis

1/n octave analysis (ORNV-OCT)
method Digital filter operation on time domain
Analysis band 1/1, 1/3, 1/12, 1/24 octave (IEC1260: 1995 Class 1, ANSI S1.11-1986)
Analysis frequency Simultaneous analysis of all channels at 20kHz is possible (DSP option may be required)
Average Fast, Slow, lmpulse, LEQ, constantBT, linear repeat,exponential
Multi-sound level meter [ORNV-OVA]
Operation method Time series signal digital operation
Acoustic weithing Linear, A, C
Measurement Leq, Fast, Slow, lmpulse, average, Peak, Max, Min
Average Fast, Slow, lmpulse, LEQ, constantBT, linear repeat,exponential
Synchronous Order tracking analysis [ORNV-ORD]
Analysis function Instantaneous and average spectrum,phase, order profile and overall.
Maximum rotation speed 1,200,000 RPM
Max analysis ordersetting 6.25, 12.5, 25, 50, 100, 200, 400
Number of analysis lines 25-800
Analysis bandwidth resampling method and fixed sampling method
display Simultaneous display of 3D display and tracking order, simultaneous display of time signal
Rotational torsion analysis [ORNV-IVC]
Operation method Digital Frequnecy Voltage converter
Number of analysis channels 2ch 2ch (up to 6ch as an option)
Rotation diagnosis function [ORNV-FFTDiag]
Analysis items Envelope analysis, cepstrum, self-cross function, MAX, MIN, peak detection from block data, simulated tach,
Output Channel
Number of output channels 1ch (lemo conector, include) no output 2ch 2ch (up to 6ch as an option)
Output waveform Sinus, step sinus, sweep sinus, chirp, multi-sinus, random (pink and white), DC voltage, record signal Sinus, step sinus, sweep sinus, chirp, multi-sinus, random (pink and white), DC voltage, record signal
Digital / Analogic converter 24 bits 24 bits
Output voltage +/- 10V +/- 10V
Output Inpedence 50 Ω 50 Ω
Frequency range ~ 100kHz ~ 40kHz
Sweep mode Sweep and step, analyze, trigger and sync, linear and log Sweep and step, analyze, trigger and sync, linear and log
Synchronization with the analysis Synchronization and free run Synchronization and free run
Output protection Stabilization with time specification and forced stop button Stabilization with time specification and forced stop buttoz
Data
Image and print Image, printing for Windows and user template creation function for Word and Excel
File TXT, UFF, MATLAB, WAV (OROS and Audio) SDF, binary, ATFX (optional)
Data entry WAV, TXT, UFF and OR20 series AE2
Dimensions / weight
Dimensions (width x height x depth mm) 35 x 110 x 185 37 x 174 x 120 56 × 246 × 222 102 x 260 x 311 102 x 364 x 311
Weight 0.5kg 0.85kg 2.8kg 5.2 kg 8.2 kg
Power supply
AC AC 100V-240V
DC USB 3.0 type C 5V USB 15V 10V-28V, 20VA 10V-28V, 60VA 10V-28V, 100VA
DC battery internal operating time (built-in) NA : using PC battery 4h 3h 2h 2h
Recommended operating temperature range 0 ℃ ~ 40 ℃ 0 ℃ ~ 50 ℃ 0 ℃ ~ 45 ℃
cooling fan Fan less Fan less Automatic control by built-in temperature sensor, forced stop possible (however, forced ON when the temperature rises above 50 ° C)


PC requirement

Connections Type: Ethernet, Connector: RJ45
Operating systems Windows 7 / Windows 10 / Windows 11
Recommended CPU : Quad core processor (Desktop : Intel Core i3 or Ryzen 3, Laptop : Intel Core i5 or Ryzen 5)

RAM : 6 GB
Storage : SSD, 1 GB free + storage for signals



Function

  • REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Level Meter
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 13.png Waterfall analysis (three-dimensional display)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png Signal record and post analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Resonance frequency by impact hammer
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Vibration on rotordynamics (orbit,...)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Modal Analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Power
  • REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Frequency analysis, spectrum analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Noise / acoustic analysis
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 10.png Time series analysis (data logger)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Vibration of rotating machines
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Customization (ex: automatic measurement)
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Sound Quality
    REF-MAN VOL1 Analyzer Settings Browser wiki partA 12.png Monitoring

  • Catalog download

    noise and vibration catalog download






    Download











    Applications/ Case study

    Main application and commonly used functions:

    FFT analyzers are used in research and development, quality control, inspection, service departments, etc.

    Improvements in vehicle quietness, ride quality, comfort, maneuverability, etc.

    Automotive noise and vibration


    Responding to quality problems caused by vibration and noise of vehicles and rotating equipment

    rotating machine vibration


    Environmental problems caused by noise from construction machinery, office machines, home appliances, etc.

    Acoutsic and vibration application


    Problems with processing accuracy due to minute vibrations in microscopes, machine tools, semiconductor manufacturing equipment, etc.

    Accuracy measurement


    A collection of application examples using the OROS FFT analyzer OROS series

    Introducing solution examples that can be provided by various functions unique to OROS FFT analyzers.


    • Vibration measurement of cutting machine
    Vibration measurement of cutting machine


    Introducing what approach can be taken using the OROS FFT Analyzer to identify mechanical resonance problems due to changes in cutting conditions.
    Download on my.oros.com (need register)




    • Monitoring of wind power generation equipment and abnormality diagnosis
    Monitoring vibration

    Measuring vibration noise generated from rotating machines (gearboxes, generators, etc.) in wind power generation equipment is indispensable for equipment maintenance and longevity. In addition to the real-time analysis capability of rotating machinery, which is the strength of the OROS FFT analyzer, remote control / monitoring and stand-alone functions can be used to more efficiently diagnose equipment for wind power generation equipment.
    Download on my.oros.com (need to register)

    • Diesel engine camshaft rotational twist measurement
    Diesel engine camshaft rotational twist

    In the prototype of a small diesel engine, there is a problem that the rotational torsional vibration of the timing belt and the camshaft resonates, causing a large vibration. By measuring rotational fluctuations and rotational twists with high accuracy using the six tachometer channels mounted on the OROS FFT analyzer, it is clarified which rotational order is dominant for vibration.

    Download on my.oros.com (need register)



    Some references:

    airplane automotive energy measurement

    Full technical support

    • Hotline dedicated
    expert on noise and vibration

    Responsiveness is the key to offer the best level of services. OROS relies on a powerful network of subsidiaries, offices, resellers, maintenance centers and qualified partners. They are the first steps of efficiency.

    Tel: +33.4.76.90.52.40
    Email: customer.care@oros.com

    Your local distributor

    • User training course

    OROS proposes training specially dedicated to customers every year for free (depending on countries). This is an opportunity to take advantage of your analyzer system capabilities, to get premium information on OROS range evolution, to discuss with your peers, and for OROS, to listen to your product enhancement desires.
    Korean vibration camp

    • Worldwide presence and accredited maintenance center

    With a worldwide coverage of distributor network and maintenance center (China, Europe, India, Japan, Saudi Arabia, South Korea, USA), OROS is in close proximity to its customers, reducing maintenance downtime.
    maintenance center
    Find Your local distributor

    calibration repair metrologic instrument



    Technicians are certified on a regular basis by OROS specialists, enabling them to repair, calibrate and upgrade all OROS systems.


    • Premium contract

    1, 2 or 4 years renewable contracts to extend your warranty.

    • Access to the latest software version.
    • Full coverage on your instrument (calibration and maintenance)
    • Guaranteed turn around time (4 days) for hardware repairs and calibration
    • Privileged access to extended services at a preferential rate: urgent loan within 1 day.

    Video content

    We have released videos such as product introductions and demonstrations.

    Click here for the youtube video content page

    Schedule a demo Get a quotation Contact support