Difference between revisions of "Human Vibration"

Jump to navigation Jump to search
493 bytes added ,  13:09, 1 December 2020
Line 176: Line 176:


======VDV======
======VDV======
The VDV is the Vibration Dose Value. It is calculated as
The VDV is the forth power Vibration Dose Value. It is calculated as a cumulative sum of the weighted acceleration at the forth power. The forth power is used to give more weight to the transient event of the signal over the periodic event. Therefore, this indicator must be used to asses the effect of shock on human health and comfort. The VDV is calculated for each channel and expressed in m/s^(1.75).<br>
 
If the "VDVTexp" box is checked, an evaluation of the VDV value over a longer time period will be calculated of each channel as : <br><br>


======MSDV======
======MSDV======

Navigation menu