8,877
edits
Line 455: | Line 455: | ||
FFT Bandwidth: set in ''FFTx/FFT analysis/range'' | FFT Bandwidth: set in ''FFTx/FFT analysis/range'' | ||
===Settings=== | ===Settings=== | ||
[Image:Reports_Tools_Ribbons_396.png|framed|right]] | [[Image:Reports_Tools_Ribbons_396.png|framed|right]] | ||
Note: Up to 2 SOA plug-in can be present in the software configuration, each of them running independent analyses on the same or different channels. | Note: Up to 2 SOA plug-in can be present in the software configuration, each of them running independent analyses on the same or different channels. | ||
* [[Image:Reports_Tools_Ribbons_398.png]] Max order: Setup the order analysis range for the plug-in from 6.25 to 400. | |||
* | * | ||
[[Image:Reports_Tools_Ribbons_399.png]] | |||
[[Image:Reports_Tools_Ribbons_399.png | |||
Associated tach: Select the tachometer to be used for signal re-sampling. The order results provided by the SOAx plug-in are related to this tachometer speed | Associated tach: Select the tachometer to be used for signal re-sampling. The order results provided by the SOAx plug-in are related to this tachometer speed | ||
* | * | ||
[[Image:Reports_Tools_Ribbons_400.png | [[Image:Reports_Tools_Ribbons_400.png]] | ||
Order resolution: Select the analysis resolution in orders. Ranges from 1/32 (0.03125) to 1 order. | Order resolution: Select the analysis resolution in orders. Ranges from 1/32 (0.03125) to 1 order. | ||
* | * | ||
Line 575: | Line 573: | ||
Contains the settings related to the type of averaging of the signals to be computed. | Contains the settings related to the type of averaging of the signals to be computed. | ||
* '''Domain''': You can chose between Spectral and Time: the spectral domain averaging computes the average after Order spectrum processing, while time domain averaging the average before Order spectrum processing. | * '''Domain'''[[Image:Reports_Tools_Ribbons_400.png]]: You can chose between Spectral and Time: the spectral domain averaging computes the average after Order spectrum processing, while time domain averaging the average before Order spectrum processing. | ||
* '''Size''': The number of signal blocks used to compute the average, from 1 up to 1000000000. | * '''Size''': The number of signal blocks used to compute the average, from 1 up to 1000000000. | ||
* '''Type''': The method of averaging the signal. There are four different averaging modes: Linear, Exponential, Peak hold, and Referenced Peak hold. | * '''Type''': The method of averaging the signal. There are four different averaging modes: Linear, Exponential, Peak hold, and Referenced Peak hold. | ||
Line 627: | Line 625: | ||
Max Speed / Min Speed = 64 | Max Speed / Min Speed = 64 | ||
* '''Max order''': defines the highest order that can be computed. Range from 6 | * '''Max order'''[[Image:Reports_Tools_Ribbons_398.png]]: defines the highest order that can be computed. Range from 6,25 to 800. | ||
*'''Order resolution'''[[Image:Reports_Tools_Ribbons_400.png]]:: Defines the resolution of the Order spectra. Resolution = Max order / Number of lines | |||
Available resolutions are: 1, ½, ¼, 1/8, 1/16 and 1/32 of order | Available resolutions are: 1, ½, ¼, 1/8, 1/16 and 1/32 of order | ||
*'''Overlap''': defines the amount of overlap of blocks of signal between 2 successive Order FFT computations expressed in revolutions, from 0 to 1/Order resolution For example: if ''Order resolution'' setting is 1/8, then Overlap range is from 0 to 7. | |||
'''Overlap''': defines the amount of overlap of blocks of signal between 2 successive Order FFT computations expressed in revolutions, from 0 to 1/Order resolution For example: if ''Order resolution'' setting is 1/8, then Overlap range is from 0 to 7. | |||
* '''Angular Overlap''': defines the overlap (in angle) corresponding to a rotation fraction. This setting is comprised between 0 and 1 rotation-SOA angular resolution with one rotation equal to 2*PI or 360° depending on the physical quantity used for the angle. The resolution (in radian) is equal to 2*PI/number of samples per rotation (=(number of lines -1)*2.56*order resolution). This setting is only available for a spectral averaging mode (in time domain it is forced to 0 and it is not modifiable). To have the maximal overlap when the resolution is <nowiki><</nowiki>1, the "Overlap" and the "Overlap in rev" must be at their maximum. | * '''Angular Overlap''': defines the overlap (in angle) corresponding to a rotation fraction. This setting is comprised between 0 and 1 rotation-SOA angular resolution with one rotation equal to 2*PI or 360° depending on the physical quantity used for the angle. The resolution (in radian) is equal to 2*PI/number of samples per rotation (=(number of lines -1)*2.56*order resolution). This setting is only available for a spectral averaging mode (in time domain it is forced to 0 and it is not modifiable). To have the maximal overlap when the resolution is <nowiki><</nowiki>1, the "Overlap" and the "Overlap in rev" must be at their maximum. |