Difference between revisions of "NVGate Software overview"

Jump to navigation Jump to search
2,495 bytes removed ,  14:04, 21 April 2020
Line 486: Line 486:


It is possible to check the results one by one with the ''Save Selection'' window by clicking on the corresponding button at the bottom-right of the window
It is possible to check the results one by one with the ''Save Selection'' window by clicking on the corresponding button at the bottom-right of the window
=====Autobandwidth=====
======Principle======
NVGate V11.00 manages the (post-)analysis and recording bandwidths automatically.
The new ''Inputs selection'' window '''allows the use of 2 different sampling rates for the dynamic inputs'''. It gathers inputs with the same physical quantity into groups, maintaining the same sampling into each group.
When inputs are associated with '''the analysis plug-in, it adjusts its analysis bandwidth to match the inputs ones'''. Mixing input bandwidths in one analysis plug-in lead to set its bandwidth to the lowest one.
''Autobandwidth'' is set by default in the concerned plug-ins.
======Recorder======
When inputs are associated with the recorder, it adjusts the recording bandwidths channel by channel.
[[Image:Usersmanual_119.png|framed|none]]
Deactivating the recorder<nowiki>’</nowiki>s ''Autobandwidth'' allows managing the dynamic inputs sampling from the recorder. Out of the case of recording signal at lower frequency than the analysis, it is recommended to keep the recorder ''Autobandwidth'' active.
======FFTx, TDA & OCT Plug-ins======
Each of these plug-ins proposes a setting that '''adjusts the analysis bandwidth'''.
* FFT\FFT Analysis\Range
* 1/n octave\CPB filters\Upper central freq.
* Time Domain\Analysis\ Range
These settings are available from manual setup if the ''Autobandwith'' is disabled.
When it is enabled in the plug-in, these settings '''switch to informative status''' (or hidden for the recorder) and '''are automatically set'''.
======SOA & OVA Plug-ins======
'''These plug-in analyzers are not compatible with Autobandwidth functions:'''
The SOA plug-in manages its upper analysis frequency according to the ''Max order'' and ''Max speed'' settings: ''Upper frequency = Max speed/60 * Max order. ''The SOA ''Upper frequency'' is limited by the ''High sampling'' of the front-end or by the ''Max bandwidth'' of the Player in post-analysis.
The OVA plug-in doesn<nowiki>’</nowiki>t manage any analysis bandwidth. It analyses the signals at the high sampling of the front end or the ''Max bandwidth'' of the Player in post-analysis.
======Post-analysis======
For the FFT, OCT, TDA, & Recorder, the ''Player/Selected record/Max bandwidth'' is ignored. The plug-ins<nowiki>’</nowiki> bandwidths are '''adjusted as in on-line mode'''.
SOA and OVA plug-in will operate as in previous version. These plug-ins will accept the signals with the same bandwidth as the ''Max bandwidth'' of the Player only.


===Interface description===
===Interface description===