Difference between revisions of "External tools: Rosette computation"

Jump to navigation Jump to search
Line 186: Line 186:


----
----
== Troubleshooting ==
{| class="wikitable" style="width:100%"
|-
! Symptom !! Likely cause !! Solution
|-
| ''Error — no signal loaded in NVGate player'' || NVGate Player is empty or paused at the beginning || Load and play a signal in NVGate before launching the computation
|-
| ''Error — duplicate channel selection'' || The same channel is selected for two or more gauges || Select a distinct channel for each of ε A, ε B, ε C
|-
| ''Error — Young modulus is not a valid number'' || Non-numeric text in the E field || Enter a numeric value, e.g. <code>210e9</code> or <code>210000000000</code>
|-
| Channel dropdown is empty || NVGate is not open, or measurement has no channels || Ensure NVGate is running with a measurement loaded in the Player
|-
| Output measurement not visible in NVGate || NVGate Project Manager not refreshed || Click '''Refresh PM''' in NVGate, or close and reopen the project
|-
| Stress values seem too high || Wrong unit for E (GPa entered instead of Pa) || Enter E in '''Pascals''': 210 GPa = <code>210000000000</code> Pa
|-
| Angle output is always near zero || Gauges A and C have nearly identical strain || This is physically correct — it means the principal axis is nearly aligned with gauge A
|}
----