NVGate Ribbons: Analysis

From OROS Wiki
Jump to navigation Jump to search

Front-end group

Analyses Front end 2022.PNG

Control/command the Front-end sampling high frequency and low frequency. Note: The plug-in analyzer and the recorder can reduce their respective bandwidths independently. This setting fixes the acquisition time accuracy and fixes the max signal bandwidth.

See Front-end/inputs settings for details.

Player group

Analysis player 2022.PNG

Analysis recorder settings 2022.PNG Connect tracks: .
Reports Tools Ribbons 276.png Record number:
Reports Tools Ribbons 276.png Player settings:
Reports Tools Ribbons 276.png Playback mode:
Reports Tools Ribbons 276.png Step:
Reports Tools Ribbons 276.png Plause/Cont.:


Record group

Analysis record 2022.PNG

Analysis recorder settings 2022.PNG Recorder settings: Give a direct access to the Recorder settings.
Reports Tools Ribbons 276.png Record status: Controls the recorder location and activity.
  • If the setting is set to Off, the icon is grayed.
  • If the setting is set to PC, the signals are recorded on the PC HDD.
  • If the setting is set to Analyzer, the signals are recorded on the analyzer's disk.
Analysis record available.PNG Available: Display the maximum possible recording duration depending on the current recorder setup. The max duration is computed from the free space of the selected hard disk, the number of tracks (and their corresponding sampling frequency) and the number of records.

Note: in time to stop mode, the max duration may also be limited by the local available memory (PC/Analyzer) for the description blocks.

Reports Tools Ribbons 274.png Arm (CTRL+SHIFT+R): Arm the recorder. Prepare the recorder to start immediately on the run. Arming process can lap a few seconds. If the recorder is not armed, it will take a few second to achieve the arming prior to effectively start recording the data.

Note: modifying a setting of the analyzer will disable the arming. It is then necessary to re-arm it.

Reports Tools Ribbons 275.png Manual trigger (CTRL+T): Generate a manual trigger event. This event is available for the event list and can be associated to the plug-in triggers (start/stop or trigger). See acquisition tab description.

Warning: While the manual trigger is not associated to a plug-in, it has no effect.

Reports Tools Ribbons 278.gif Record mark: Allow adding a mark with comments while recording. These marks are available when the signal file is edited.


Plug-in group

Analysis Plug in 2022.PNG

These buttons give a direct access to the plug-in settings. Note: only the plug-ins available with the user licenses are displayed.

Monitor settings
TDA settings
FFT settings
SOA settings
OCT settings
OVA settings

Waterfall group

Analysis Waterfall 2022.PNG