Line 134: |
Line 134: |
| The [[NVGate_Ribbons:_Home_Tab|home tab]], let you a quick access to all this settings, and more! : | | The [[NVGate_Ribbons:_Home_Tab|home tab]], let you a quick access to all this settings, and more! : |
| [[File:home3.PNG|800px]] | | [[File:home3.PNG|800px]] |
|
| |
| ====GoToResult====
| |
|
| |
|
| |
| Available from both the bottom bar and ''Home\Start\Select Inputs'' this window allows selecting the inputs to be used and setups their acquisition.
| |
|
| |
|
| |
| '''Access to the ''' ''GoToResult'' '''windows is continuously available from the NVGate bottom bar.'''
| |
|
| |
| The 2 first buttons control the visibility of the corresponding windows ''Inputs selection'' and ''Show results''. Click once to show the window, click again to hide it. The 3<sup>rd</sup> button only opens the ''Results overview''.
| |
|
| |
| These 3 buttons show the windows described below.
| |
|
| |
| [[Image:V11_release_08.png|framed|none]]
| |
| Hide the window by clicking on its control button, closing the window (up-right red cross), clicking on the ''Results'' button to show the next window.
| |
|
| |
| ===== Step 1: Inputs selection=====
| |
| [[Image:Usersmanual_26.png|framed|none]]
| |
|
| |
| ======Usage======
| |
| The ''Inputs selection'' window '''allows access to the other items of the NVGate''' '''interface''' (ex: ''check ICP, Autorange'', change sampling frequencies, graphs…) while it remains open.
| |
|
| |
| [[Image:Usersmanual_110.png|700px|none]]
| |
|
| |
| The actions in this window apply immediately to the analysis, there is no possible cancel. In the same way actions in other parts of NVGate are immediately reflected in this window.
| |
|
| |
| This window manages dynamic inputs only. For using parametric, CAN or ext. synch inputs, one should use the acquisition tab of the ribbon.
| |
|
| |
| ======Operations======
| |
| The Inputs selection window allows activating and setting-up the dynamic inputs in a fast and smart way. Inputs are activated and set to a physical quantity when the corresponding check box is clicked.
| |
|
| |
| ======Selection======
| |
| This table allows selecting one or multiple cells in an Excel like mode, using '''mouse drag,''' '''keyboard arrows''' and '''SHIFT/CTRL''' keys. After editing, the focus is automatically set to the next cell for continuous operation with the keyboard:
| |
|
| |
| {|class="wikitable" style="background:white" border="0" cellspacing="0" cellpadding="4" width="50%"
| |
| |Exit key
| |
| |Return
| |
| |Tab
| |
| |Left arrow
| |
| |Right arrow
| |
| |Up arrow
| |
| |Down arrow
| |
|
| |
| |-
| |
| |Next cell
| |
| |Down
| |
| |Right
| |
| |Left
| |
| |Right
| |
| |Up
| |
| |Down
| |
|
| |
| |}
| |
|
| |
| ======Edition======
| |
| Editing a cell or a group of cells is direct, '''no need to double click''', '''simply enter the values''' or initials for combo boxes. Hit the <nowiki><</nowiki>Space<nowiki>></nowiki> key to open the combo with the current selection. This allows using the keyboard only while setting cells in a column or a line.
| |
|
| |
| ======Add physical quantities======
| |
| The 3 basic physical quantities (Voltage, Acceleration and Acoustic pressure) used in noise and vibration are proposed as default. '''Changing one input physical quantity will add a new column''' with this physical quantity.
| |
|
| |
| In addition to the basics and active physical quantity, the columns also show the physical quantities of deactivated inputs. '''This is useful to add default physical quantities to your models'''.
| |
|
| |
| ======Transducers======
| |
| The list of possible transducers is '''adjusted to the input physical quantity'''. Ex: if an input is set to acoustic pressure, only a microphones<nowiki>’</nowiki> list is proposed.
| |
|
| |
| ======Sampling & groups======
| |
| The sampling setting is new. It '''defines the recording sampling and the analysis bandwidth for each group of inputs'''. The groups correspond to the inputs physical quantities. See the ''Autobandwidth'' chapter for more details
| |
|
| |
| There are 2 samplings, ''High'' and ''Low''. Each sampling can be adjusted from the table with ''Right click -<nowiki>></nowiki> Change -<nowiki>></nowiki> Select new sampling.''
| |
|
| |
| '''Changing the sampling of one input will apply to all input in the same group'''. For applying different samplings to inputs with same physical quantity, use the ASB.
| |
|
| |
| Sampling settings are also available from the ribbon Measurement\Front-end\High Samp. and Low Samp. and from the Front-end Module in the Analysis Setting Browser.
| |
|
| |
| ======Record signals======
| |
| Check this box to '''ensure the recording of all active inputs'''. This includes the DC inputs (parametric), the Ext Sync. and the CAN ones.
| |
|
| |
| Unchecking this box just set the recorder to off. The inputs remain set in the recorder. This is helpful to '''temporarily pause the inputs recording'''; especially on setup fine tuning.
| |
|
| |
|
| |
| [[Image:Usersmanual_05.png|framed|none]]
| |
|
| |
| The Record signal is also available from the ribbon Measurement\Front-end\Records signal. And from the show results window.
| |
|
| |
| All instances of this setting work in the same way. Wiith this method, the recorder signals are not automatically displayed.
| |
|
| |
| A new button is available to '''monitor temporarily or continuously the signal:''' ''Measurement\Control\View recording''. '''It opens the signal monitoring window on top of the current layout'''. In the case of this window is already open in another layout, it swaps to this layout.
| |
|
| |
| ======Access to all======
| |
| By default, the window shows only the basic settings. In order to get the full columns, '''flyover the right side of the table and click on the grayed arrow'''.
| |
|
| |
| [[Image:Usersmanual_111.png|framed|none]]
| |
|
| |
| Same with the left arrow to return to the basic view.
| |
|
| |
| ======Post-analysis======
| |
| ''Inputs selection'' window works on both on-line and post-analysis modes.
| |
|
| |
| =====Step 2 Show results=====
| |
| [[Image:Usersmanual_28.png|framed|none]]
| |
| ======Call======
| |
| Available from both the bottom bar or directly following the ''Inputs Selection'' window, this window allows '''displaying and saving results from activated inputs'''.
| |
|
| |
| Hide the window by clicking on its control button closing the window (up-right red cross) or by clicking on its corresponding button in the NVGate bottom bar.
| |
|
| |
| [[Image:Usersmanual_112.png|700px|none]]
| |
|
| |
| ======Usage======
| |
| The ''Show results'' window '''allows access to the other items of the NVGate interface''' (''Add/Change layout, Setup tachometer''…) while it remains open.
| |
|
| |
| [[Image:Usersmanual_30.png|framed|none]]
| |
|
| |
| The actions in this window apply immediately to the analysis, there is no cancel possible from this window. In the same way, actions in other parts of NVGate are immediately reflected in this window.
| |
|
| |
| This window manages to connect and display result from FFTx, SOAx, OCT plug-ins only. For results from TDA and OVA, one should use the ''Acqusition\Inputs\Connect inputs'' button followed by the ''Display/Graphs''\''Windows\Add/Remove'' one from the ribbon.
| |
|
| |
| ======Show results======
| |
| The Show ''results'' window allows displaying and saving results without connecting inputs or tracks to the plug-in analyzers in advance.
| |
|
| |
|
| |
| Results to be displayed are selected as follows:
| |
|
| |
| 1. Select the plug-in which calculates the results,
| |
| [[Image:Usersmanual_38.png|framed|none]]
| |
|
| |
|
| |
|
| |
| 2. select the results<nowiki>’</nowiki> familly between:
| |
|
| |
| * ''Main'' is for results imediatelly provided by the analysis like the trigger blocks, RPM, spectra, FRFs, …
| |
| * ''Profile'' is for scalar profiles like order tracking, acoustic level, RPM profiles, …
| |
| * ''Waterfall ''is for 3D results.
| |
| 3. Select the result type,
| |
|
| |
| 4. select the Inputs/Tracks to be displayed. This list '''gathers the sources in groups according to their physical quantities'''. One can develop the group for partial selection.
| |
|
| |
| Go. Use the ''Show'' button to display your selection. This button operates in 2 ways:
| |
|
| |
| * <u>Add a new window</u> in the current layout with the selected results by clicking the button
| |
| * Drag & Drop the button to an existing window of the current layout to <u>add the selected results in this window</u>.
| |
|
| |
| ======References======
| |
| Cross functions (FRFs, ORFs, Coherence, etc..) are selected through the bottom right area. The references are displayed as the inputs/tracks using the physical quantity group. There is no need to predefine the cross function from the Plug-in settings.
| |
|
| |
| ======Orders and overall======
| |
|
| |
| [[Image:Usersmanual_04.png|framed|none]]
| |
|
| |
| For order tracking, the Show results window features a fast and simple order selection mode. While selecting order-based result, one can enter the chosen orders in the bottom right area of the window.
| |
|
| |
| Values are entered directly using the keyboard; The Enter and up/down keys will navigate to next or previous lines in the list.
| |
|
| |
| If the plug-in channels show different orders to track for one line, "Mixed" will be displayed.
| |
|
| |
| ======Save results======
| |
| Results to be saved (i.e. added to the save selection list) are selected as for showing it.
| |
|
| |
| There are 3 ways to save the results:
| |
|
| |
| * Manually by using the save button. This will add the selected results to the save selection.
| |
| *
| |
| [[Image:Usersmanual_113.png|framed|none]]
| |
| Automatically and continuously, by checking the Save displayed results check box at the bottom of the window. This will continuously add the displayed results to the save selection. Results remain in the save selection list, even if they are removed from the layout.
| |
| *
| |
| [[Image:Usersmanual_27.png|framed|none]]
| |
|
| |
| Automatically once by using Measurement\Save\Add All Results button from the ribbon. This button acts like the save all display result but only at once.
| |
| * This button is grayed when all displayed results are already in the save selection
| |
| * When the Save displayed results is active, this button shows
| |
| ======Parameters======
| |
| The bottom half of the window allows adjusting the selected plug-in parameters and triggering.
| |
|
| |
| [[Image:Usersmanual_114.png|framed|none]]
| |
|
| |
| 1. This button opens the active plug-in properties. NB: it is also possible to access it from the ribbon while the window is open. Helpful with the directly available main settings.
| |
|
| |
| 2. Click here to open the ''Events connection'' window, where one can '''associate event with plug-ins<nowiki>’</nowiki> Start, stop or trigger'''.
| |
|
| |
| 3. Activate the plug-in tach with this combo box. The tachometer properties will be proposed just after selecting the tach. The corresponding input (dynamic, or ext. synch) is automatically activated. <br>NB: The selected tachometer is associated with the plug-in. For profile and waterfall results, the corresponding tachometer is showed as: XXX tach (ex. FFT1 tach, or SOA2 tach)
| |
|
| |
| 4. Click on the engine tachometer icon to setup the delta RPM for scheduled analyses with ''Profiles'' and ''Waterfalls''.
| |
|
| |
| =====Step 3 Results overview=====
| |
| ======Call======
| |
| Available from the bottom bar. This window '''shows a synthetic table of the displayed and saved results'''. Close the window by clicking on its control button closing the window (up-right red cross).
| |
|
| |
| ======Usage======
| |
| The table summarizes all the displayed and saved result (i.e. present in the Save Selection list), by:
| |
|
| |
| * Plug-ins
| |
| * Type of results
| |
| * Groups (i.e. Physical quantity)
| |
| The 2 columns at the right, indicate what is done with each set of results. ''Show'' for the displayed results and ''Save'' for the to-be-saved results.
| |
|
| |
| [[Image:Usersmanual_115.png|framed|none]]
| |
|
| |
| The check boxes have 3 possible status:
| |
|
| |
| *
| |
| [[Image:Usersmanual_116.png]]
| |
| Checked, means all the inputs with these type and physical quantity, calculated by the plug-in are saved and/or displayed.
| |
| *
| |
| [[Image:Usersmanual_117.png]]
| |
| Unchecked, means none of the inputs with these type and physical quantity, calculated by the plug-in are saved and/or displayed.
| |
| *
| |
| [[Image:Usersmanual_118.png]]
| |
| Partial, means only a part of the inputs with these type and physical quantity, calculated by the plug-in are saved and/or displayed.
| |
| One can check and uncheck the ''Save'' column boxes. Partial status boxes change to checked or unchecked only.
| |
|
| |
| It is possible to check the results one by one with the ''Save Selection'' window by clicking on the corresponding button at the bottom-right of the window
| |
|
| |
|
| ===Interface description=== | | ===Interface description=== |