Line 197: | Line 197: | ||
Specific filters are used to weight the acceleration signal before calculating the <math>D_k</math>. These filter are different for the vertical and horizontal direction, and are defined for a sampling rate of 160 Sample/second. Therefore, we advise to [[NVGate Recorder|record]] the signal with a low [[NVGate_Front_End#Input_settings|sampling rate]] in NVGate.<br> | Specific filters are used to weight the acceleration signal before calculating the <math>D_k</math>. These filter are different for the vertical and horizontal direction, and are defined for a sampling rate of 160 Sample/second. Therefore, we advise to [[NVGate Recorder|record]] the signal with a low [[NVGate_Front_End#Input_settings|sampling rate]] in NVGate.<br> | ||
Assessing the affect of the vibration on human spine most is important when dealing with transportation vehicular, especially from driver seat. for a better evaluation, the ISO 2631-5 | Assessing the affect of the vibration on human spine most is important when dealing with transportation vehicular, especially from driver seat. for a better evaluation, the ISO 2631-5 advise to calculate the daily acceleration dose, defined as : <br> | ||
<math display="block" forcemathmode="5">D_{X,Y,Z}(T) = D_{X,Y,Z}*\sqrt[6]{\frac{T}{T_m}}</math> <br> | <math display="block" forcemathmode="5">D_{X,Y,Z}(T) = D_{X,Y,Z}*\sqrt[6]{\frac{T}{T_m}}</math> <br> |