The <math>A_w</math>  is the RMS of the weighted acceleration signal. The weighting is applied in accordance with the direction set for each channel and the weighting filter defined for the direction.<br>
The <math>A_w</math>  is the RMS of the weighted acceleration signal. The weighting is applied in accordance with the direction set for each channel and the weighting filter defined for the direction.<br>


For each channel, the <math>A_w</math> and <math>A_w(T)</math> will be calculated. The <math>A_w(T)</math> is the Daily exposure value, defined as : <br><br>
For each channel, the <math>A_w</math> and <math>A_w(T)</math> will be calculated. The <math>A_w(T)</math> is the daily exposure value, defined as : <br><br>
<math display="block" forcemathmode="5">A_w(T) = A_w*k_{i}*\sqrt{\frac{T}{T_m}}</math>  
<math display="block" forcemathmode="5">A_w(T) = A_w*k_{i}*\sqrt{\frac{T}{T_m}}</math>  
<br>
<br>
With <math>T_m</math> the duration of the measurement and <math>T</math> the total exposure duration represented by the "Reference time" parameter. the <math>k_i</math> factor is defined in the ISO 2631 as <math>k_X = k_Y = 1.4</math> and <math>k_Z = 1</math>.
With <math>T_m</math> the duration of the measurement and <math>T</math> the total exposure duration represented by the "Reference time" parameter. the <math>k_i</math> factor is defined in the ISO 2631 as <math>k_X = k_Y = 1.4</math> and <math>k_Z = 1</math>.


When comparing result from one measurement point in the three direction, the maximum of the Daily exposure value must be used as the total daily exposure value at that point :<br><br>
When comparing result from one measurement point in the three direction, the maximum of the daily exposure value must be used as the total daily exposure value at that point :<br><br>
<math display="block" forcemathmode="5">A_w(T) = max(A_{wX}(T), A_{wY}(T), A_{wZ}(T)) </math>
<math display="block" forcemathmode="5">A_w(T) = max(A_{wX}(T), A_{wY}(T), A_{wZ}(T)) </math>
<br>
<br>
======av======
======av======
The <math>a_v</math>  is the total RMS vibration value of the weighted acceleration signal. This value will only be calculated if a sensor have been defined in the definition of direction window.
The <math>a_v</math>  is the total RMS vibration value of the weighted acceleration signal. This value will only be calculated if a sensor have been defined in the definition of direction window.