Difference between revisions of "NVGate Synchronous Order Analysis"

Jump to navigation Jump to search
Line 455: Line 455:
FFT Bandwidth: set in ''FFTx/FFT analysis/range''
FFT Bandwidth: set in ''FFTx/FFT analysis/range''
===Settings===
===Settings===
[Image:Reports_Tools_Ribbons_396.png|framed|right]]
[[Image:Reports_Tools_Ribbons_396.png|framed|right]]
Note: Up to 2 SOA plug-in can be present in the software configuration, each of them running independent analyses on the same or different channels.
Note: Up to 2 SOA plug-in can be present in the software configuration, each of them running independent analyses on the same or different channels.


* [[Image:Reports_Tools_Ribbons_398.png]] Max order: Setup the order analysis range for the plug-in from 6.25 to 400.
*  
*  
[[Image:Reports_Tools_Ribbons_398.png|framed|none]]
[[Image:Reports_Tools_Ribbons_399.png]]
Max order: Setup the order analysis range for the plug-in from 6.25 to 400.
*
[[Image:Reports_Tools_Ribbons_399.png|framed|none]]
Associated tach: Select the tachometer to be used for signal re-sampling. The order results provided by the SOAx plug-in are related to this tachometer speed
Associated tach: Select the tachometer to be used for signal re-sampling. The order results provided by the SOAx plug-in are related to this tachometer speed
*  
*  
[[Image:Reports_Tools_Ribbons_400.png|framed|none]]
[[Image:Reports_Tools_Ribbons_400.png]]
Order resolution: Select the analysis resolution in orders. Ranges from 1/32 (0.03125) to 1 order.
Order resolution: Select the analysis resolution in orders. Ranges from 1/32 (0.03125) to 1 order.
*  
*  
Line 575: Line 573:
Contains the settings related to the type of averaging of the signals to be computed.
Contains the settings related to the type of averaging of the signals to be computed.


* '''Domain''': You can chose between Spectral and Time: the spectral domain averaging computes the average after Order spectrum processing, while time domain averaging the average before Order spectrum processing.
* '''Domain'''[[Image:Reports_Tools_Ribbons_400.png]]: You can chose between Spectral and Time: the spectral domain averaging computes the average after Order spectrum processing, while time domain averaging the average before Order spectrum processing.
* '''Size''': The number of signal blocks used to compute the average, from 1 up to 1000000000.
* '''Size''': The number of signal blocks used to compute the average, from 1 up to 1000000000.
* '''Type''': The method of averaging the signal. There are four different averaging modes: Linear, Exponential, Peak hold, and Referenced Peak hold.
* '''Type''': The method of averaging the signal. There are four different averaging modes: Linear, Exponential, Peak hold, and Referenced Peak hold.
Line 627: Line 625:
Max Speed / Min Speed = 64
Max Speed / Min Speed = 64


* '''Max order''': defines the highest order that can be computed. Range from 6;25 to 800. '''Order resolution''': Defines the resolution of the Order spectra. Resolution = Max order /  Number of lines
* '''Max order'''[[Image:Reports_Tools_Ribbons_398.png]]: defines the highest order that can be computed. Range from 6,25 to 800.  
*'''Order resolution'''[[Image:Reports_Tools_Ribbons_400.png]]:: Defines the resolution of the Order spectra. Resolution = Max order /  Number of lines
Available resolutions are: 1, ½, ¼, 1/8, 1/16 and 1/32 of order
Available resolutions are: 1, ½, ¼, 1/8, 1/16 and 1/32 of order
 
*'''Overlap''': defines the amount of overlap of blocks of signal between 2 successive Order FFT computations expressed in revolutions, from 0 to 1/Order resolution For example: if ''Order resolution'' setting is 1/8, then Overlap range is from 0 to 7.
'''Overlap''': defines the amount of overlap of blocks of signal between 2 successive Order FFT computations expressed in revolutions, from 0 to 1/Order resolution For example: if ''Order resolution'' setting is 1/8, then Overlap range is from 0 to 7.


* '''Angular Overlap''': defines the overlap (in angle) corresponding to a rotation fraction. This setting is comprised between 0 and 1 rotation-SOA angular resolution with one rotation equal to 2*PI or 360° depending on the physical quantity used for the angle. The resolution (in radian) is equal to 2*PI/number of samples per rotation (=(number of lines -1)*2.56*order resolution). This setting is only available for a spectral averaging mode (in time domain it is forced to 0 and it is not modifiable). To have the maximal overlap when the resolution is <nowiki><</nowiki>1, the "Overlap" and the "Overlap in rev" must be at their maximum.
* '''Angular Overlap''': defines the overlap (in angle) corresponding to a rotation fraction. This setting is comprised between 0 and 1 rotation-SOA angular resolution with one rotation equal to 2*PI or 360° depending on the physical quantity used for the angle. The resolution (in radian) is equal to 2*PI/number of samples per rotation (=(number of lines -1)*2.56*order resolution). This setting is only available for a spectral averaging mode (in time domain it is forced to 0 and it is not modifiable). To have the maximal overlap when the resolution is <nowiki><</nowiki>1, the "Overlap" and the "Overlap in rev" must be at their maximum.