Difference between revisions of "NVGate Synchronous Order Analysis"

Jump to navigation Jump to search
no edit summary
Line 361: Line 361:
* Avg. Order CrossCorr: This result is available if correlation is selected in ''the Synch. Order x/Correlation ''and ''Synch. Order x x/Average/Domain is ''Spectral or Frequency synchronous. This result is not available if there is no cell checked in the ''Synch. Order x /Order FFT/Cross spectrum ''matrix
* Avg. Order CrossCorr: This result is available if correlation is selected in ''the Synch. Order x/Correlation ''and ''Synch. Order x x/Average/Domain is ''Spectral or Frequency synchronous. This result is not available if there is no cell checked in the ''Synch. Order x /Order FFT/Cross spectrum ''matrix


'''Computation SPUs:<br>'''
===Computation SPUs:<br>===


{|border="2" cellspacing="0" cellpadding="4" width="79%" align="center"
{|border="2" cellspacing="0" cellpadding="4" width="79%" align="center"
Line 454: Line 454:


FFT Bandwidth: set in ''FFTx/FFT analysis/range''
FFT Bandwidth: set in ''FFTx/FFT analysis/range''
 
===Settings===
=====Channel=====
====Channel====
Contains the settings related to the source input.
Contains the settings related to the source input.


Line 471: Line 471:
* '''Order number''': Select the number of the order you want to track, from 0.001 up to 800
* '''Order number''': Select the number of the order you want to track, from 0.001 up to 800
* '''Weighting window''': window used to weight the signal before processing. There are 6 fixed windows: Uniform, Hanning, Hamming, Kaiser Bessel, and Flat top; 3 customized windows: Force, Response (see the Time Windows chapter) For the window characteristics, see the Appendix.
* '''Weighting window''': window used to weight the signal before processing. There are 6 fixed windows: Uniform, Hanning, Hamming, Kaiser Bessel, and Flat top; 3 customized windows: Force, Response (see the Time Windows chapter) For the window characteristics, see the Appendix.
=====Tach=====
====Tach====
Contains the Synchronous order analysis tachometer settings.
Contains the Synchronous order analysis tachometer settings.


Line 520: Line 520:
* If set to ''None'', the SOA will works on the regular way: Interpolation of the sampling dates from the RPM information).
* If set to ''None'', the SOA will works on the regular way: Interpolation of the sampling dates from the RPM information).
* If set to a sampling input, the SOA will use it for sampling the channels signals
* If set to a sampling input, the SOA will use it for sampling the channels signals
=====Trigger=====
====Trigger====
Contains the settings related to triggering events and how to start, and stop signal computation. Note that the trigger is always done on the next available revolution pulse:
Contains the settings related to triggering events and how to start, and stop signal computation. Note that the trigger is always done on the next available revolution pulse:


Line 574: Line 574:
|}<br clear="all">
|}<br clear="all">


=====Average=====
====Average====
Contains the settings related to the type of averaging of the signals to be computed.
Contains the settings related to the type of averaging of the signals to be computed.


Line 610: Line 610:
''Hidden/fixed: This setting is only available when the Referenced Peak hold averaging mode is selected.''
''Hidden/fixed: This setting is only available when the Referenced Peak hold averaging mode is selected.''


=====Order FFT=====
====Order FFT====
Transforms the order blocks into order spectra.
Transforms the order blocks into order spectra.


Line 678: Line 678:
''Hidden/fixed: fixed''
''Hidden/fixed: fixed''


=====Overall analysis=====
====Overall analysis====
Calculation of the order bands sum.
Calculation of the order bands sum.


Line 684: Line 684:
* '''Lower Order''': Specifies the lower order of the overall computation order range
* '''Lower Order''': Specifies the lower order of the overall computation order range
* '''Upper Order''': Specifies the upper order of the overall computation order range
* '''Upper Order''': Specifies the upper order of the overall computation order range
=====Correlation=====
====Correlation====
Calculation of the Auto Correlation and the Cross Correlation in the angle domain.
Calculation of the Auto Correlation and the Cross Correlation in the angle domain.
[[File:Correlation2.png|left]]<br>
[[File:Correlation2.png|left]]<br>
Line 729: Line 729:
* Use appropriate trigger mode and trigger delay. The trigger mode should be different from free run. The trigger Delay must be set to –T/2 (where T is the time signal block length) with the Uniform and Centered Zero Padding correlation weighted window (and 0 for the Left Zero Padding window). But in some cases, especially with the Centered Zero Padding and Left Zero Padding window (as these function types attenuate parts of the trigger signal block), the trigger Delay must be adjusted to position the input signal with respect to time.
* Use appropriate trigger mode and trigger delay. The trigger mode should be different from free run. The trigger Delay must be set to –T/2 (where T is the time signal block length) with the Uniform and Centered Zero Padding correlation weighted window (and 0 for the Left Zero Padding window). But in some cases, especially with the Centered Zero Padding and Left Zero Padding window (as these function types attenuate parts of the trigger signal block), the trigger Delay must be adjusted to position the input signal with respect to time.


=====SOA Status=====
===SOA Status===
All statuses are available to add to the control panel
All statuses are available to add to the control panel


======Sync. Order x======
====Sync. Order x====


[[Image:Order_analysis_40.png|framed|none]]
[[Image:Order_analysis_40.png|framed|none]]
Line 759: Line 759:
* ''Green background and red text'': the current acquisition is real-time, but since start not all the blocks were analyzed.
* ''Green background and red text'': the current acquisition is real-time, but since start not all the blocks were analyzed.


======SOAx cur.blk======
====SOAx cur.blk====


[[Image:Order_analysis_41.png|framed|none]]
[[Image:Order_analysis_41.png|framed|none]]
Line 775: Line 775:
* Stop: the acquisition is stopped
* Stop: the acquisition is stopped


======Trigger State======
====Trigger State====
The following scheme describes the different states of the measurement:
The following scheme describes the different states of the measurement:


Line 786: Line 786:
'''Note''': all start event, trigger, new revolution or run are ignored in <nowiki>’</nowiki>free run<nowiki>’</nowiki> mode
'''Note''': all start event, trigger, new revolution or run are ignored in <nowiki>’</nowiki>free run<nowiki>’</nowiki> mode


======Count======
====Count====
This status displays the averaging count processed. This status is expressed in analyzed block.
This status displays the averaging count processed. This status is expressed in analyzed block.


Line 796: Line 796:
* <nowiki>’</nowiki>'''-'''<nowiki>’</nowiki>: The acquisition is currently not real-time (current block is not analyzed an averaged).
* <nowiki>’</nowiki>'''-'''<nowiki>’</nowiki>: The acquisition is currently not real-time (current block is not analyzed an averaged).


======Block overload======
====Block overload====
This status corresponds to the instantaneous overload indication within 1 SOA trigger block, for instance amplitude overload occurred in the current analyzed block. Note that overloaded block may be automatically rejected (see accept mode).
This status corresponds to the instantaneous overload indication within 1 SOA trigger block, for instance amplitude overload occurred in the current analyzed block. Note that overloaded block may be automatically rejected (see accept mode).


======Analysis overload======
====Analysis overload====
This status corresponds to overload indication over the measurement period. It means that during the whole measurement period there was (or not) an overload. It memorizes block overloaded.
This status corresponds to overload indication over the measurement period. It means that during the whole measurement period there was (or not) an overload. It memorizes block overloaded.


[[category:Order analysis]]
[[category:Order analysis]]

Navigation menu