Difference between revisions of "NVGate EVHV"

From OROS Wiki
Jump to navigation Jump to search
(Created page with "==Introduction and overview== ===Objectives=== The objective of the EVHV module is to characterize the electromagnetic forces which are responsible of the noise emission of an...")
 
Line 7: Line 7:
* Spatiograms analysis and displays. Spatiograms are calculated based on measurements of accelerometers data distributed around the surface of the motor stator as shown in the picture below.
* Spatiograms analysis and displays. Spatiograms are calculated based on measurements of accelerometers data distributed around the surface of the motor stator as shown in the picture below.


[[Image:EVHV_01.gif|framed|none]]
[[Image:EVHV_01.gif|none]]


''Sensors positioned for Spatiograms analysis''
''Sensors positioned for Spatiograms analysis''
Line 13: Line 13:
Each spatiogram is representative of a spatial distribution of the Electromagnetic forces. The sum of the participation of each spatiogram lead to the global vibration response. Determining the spatiogram responsible of the vibration harmonic that should be decreased is one of the major objectives of the EVHV module.
Each spatiogram is representative of a spatial distribution of the Electromagnetic forces. The sum of the participation of each spatiogram lead to the global vibration response. Determining the spatiogram responsible of the vibration harmonic that should be decreased is one of the major objectives of the EVHV module.


[[Image:EVHV_02.png|framed|none]]
[[Image:EVHV_02.png|none]]


''Separation of the response in a sum of participating wavenumbers''
''Separation of the response in a sum of participating wavenumbers''
Line 22: Line 22:
===Open the project and load setup===
===Open the project and load setup===


[[Image:EVHV_03.gif|framed|none]]
[[Image:EVHV_03.gif|none]]


''Open project''
''Open project''


[[Image:EVHV_04.gif|framed|none]]
[[Image:EVHV_04.gif|none]]


''Load Setup, last saved in project''
''Load Setup, last saved in project''
Line 32: Line 32:
The setup contains 2 layouts: Spectra and Spatio
The setup contains 2 layouts: Spectra and Spatio


[[Image:EVHV_05.png|framed|none]]
[[Image:EVHV_05.png|none]]


''Display layout 1 called Spectra''
''Display layout 1 called Spectra''
Line 38: Line 38:
===Checking the eFrequencies===
===Checking the eFrequencies===


[[Image:EVHV_06.png|framed|none]]
[[Image:EVHV_06.png|none]]


''EV/HV ribbon''
''EV/HV ribbon''
Line 44: Line 44:
eMachine should be clicked to access to the following dialog. At this stage, one can select the main characteristics of the eMotor.
eMachine should be clicked to access to the following dialog. At this stage, one can select the main characteristics of the eMotor.


[[Image:EVHV_07.gif|framed|none]]
[[Image:EVHV_07.gif|none]]


''Machine definition''
''Machine definition''
Line 50: Line 50:
When the machine is configured, one can press Save. The user goes automatically to the following dialog which is the "eMarkers" one.
When the machine is configured, one can press Save. The user goes automatically to the following dialog which is the "eMarkers" one.


[[Image:EVHV_08.png|framed|none]]
[[Image:EVHV_08.png|none]]


''eMarkers table''
''eMarkers table''
Line 56: Line 56:
When pressing "Apply" the eMarkers will be displayed on the graphs of the current layout.
When pressing "Apply" the eMarkers will be displayed on the graphs of the current layout.


[[Image:EVHV_09.png|framed|none]]
[[Image:EVHV_09.png|none]]


''Spectra with the eMarkers''
''Spectra with the eMarkers''
Line 63: Line 63:


Change the Layout to reach layout2 (called Spatio). Changing layout can be achieved by clicking on  
Change the Layout to reach layout2 (called Spatio). Changing layout can be achieved by clicking on  
[[Image:EVHV_10.png|framed|none]]
[[Image:EVHV_10.png|none]]
which is located in the "Measurement" tab. A keyboard shortcut also exists: <nowiki>[</nowiki>CTRL<nowiki>+</nowiki>SPACE<nowiki>]</nowiki>
which is located in the "Measurement" tab. A keyboard shortcut also exists: <nowiki>[</nowiki>CTRL<nowiki>+</nowiki>SPACE<nowiki>]</nowiki>


===Displaying spatiograms===
===Displaying spatiograms===


[[Image:EVHV_11.png|framed|none]]
[[Image:EVHV_11.png|none]]


''Icons linked to the display of the spatiograms''
''Icons linked to the display of the spatiograms''


By opening the  
By opening the  
[[Image:EVHV_12.png|framed|none]]
[[Image:EVHV_12.png|none]]
positions editor, one can check the positions that were saved in the setup
positions editor, one can check the positions that were saved in the setup


[[Image:EVHV_13.png|framed|none]]
[[Image:EVHV_13.png|none]]


The next step is to select a measurement. In the provided project and its contained measurement, spatiograms are already calculated. One should press the icon "select measurement" as shown below. In the dialog that follows, one should type, in the filtering area: for example, Z12. This will allow to find easily the appropriate measurement.
The next step is to select a measurement. In the provided project and its contained measurement, spatiograms are already calculated. One should press the icon "select measurement" as shown below. In the dialog that follows, one should type, in the filtering area: for example, Z12. This will allow to find easily the appropriate measurement.


[[Image:EVHV_14.png|framed|none]]
[[Image:EVHV_14.png|none]]


''Selecting a measurement''
''Selecting a measurement''
Line 86: Line 86:
From that point, the spatiograms for all wavenumbers (one spatiogram for each wavenumber) will be loaded and displayed. If they are not already calculated (as it is the case of the provided project).
From that point, the spatiograms for all wavenumbers (one spatiogram for each wavenumber) will be loaded and displayed. If they are not already calculated (as it is the case of the provided project).


[[Image:EVHV_15.png|framed|none]]
[[Image:EVHV_15.png|none]]


''Loading the Spatiograms''
''Loading the Spatiograms''
Line 92: Line 92:
Following that action, the spatiograms are automatically scaled and displayed as follows.
Following that action, the spatiograms are automatically scaled and displayed as follows.


[[Image:EVHV_16.png|framed|none]]
[[Image:EVHV_16.png|none]]


''Spatiograms displays''
''Spatiograms displays''
Line 102: Line 102:
* Applying the eMarkers, confirms emarker3 placed on the spatiogram thanks to the eMarkers.
* Applying the eMarkers, confirms emarker3 placed on the spatiogram thanks to the eMarkers.


[[Image:EVHV_17.png|framed|none]]
[[Image:EVHV_17.png|none]]


''Applying eMarkers to the Spatiograms''
''Applying eMarkers to the Spatiograms''
Line 109: Line 109:


* The windows configuration can be changed using  
* The windows configuration can be changed using  
[[Image:EVHV_18.gif|framed|none]]
[[Image:EVHV_18.gif|none]]


* The scaling can be updated using the Scale on Max  
* The scaling can be updated using the Scale on Max  
[[Image:EVHV_19.png|framed|none]]
[[Image:EVHV_19.png|none]]
or the scale on displayed  
or the scale on displayed  
[[Image:EVHV_20.png|framed|none]]
[[Image:EVHV_20.png|none]]


* The reference spectrogram (after selecting it) can be changed by using  
* The reference spectrogram (after selecting it) can be changed by using  
[[Image:EVHV_21.gif|framed|none]]
[[Image:EVHV_21.gif|none]]


* The wavenumber for each spatiogram can be changed by using  
* The wavenumber for each spatiogram can be changed by using  
[[Image:EVHV_22.png|framed|none]]
[[Image:EVHV_22.png|none]]


----
----
Line 126: Line 126:
==eFrequencies: from eMachine setup to eMarkers display==
==eFrequencies: from eMachine setup to eMarkers display==
There are 2 main steps in the determination of the eFrequencies: the machine description achieved through the eMachine tab <nowiki>[</nowiki>
There are 2 main steps in the determination of the eFrequencies: the machine description achieved through the eMachine tab <nowiki>[</nowiki>
[[Image:EVHV_23.gif|framed|none]]
[[Image:EVHV_23.gif|none]]
<nowiki>]</nowiki> and the eMarkers tab <nowiki>[</nowiki>
<nowiki>]</nowiki> and the eMarkers tab <nowiki>[</nowiki>
[[Image:EVHV_24.png|framed|none]]
[[Image:EVHV_24.png|none]]
<nowiki>]</nowiki> where the eFrequencies are calculated.
<nowiki>]</nowiki> where the eFrequencies are calculated.


===eMachine===
===eMachine===
By clicking on  
By clicking on  
[[Image:EVHV_25.gif|framed|none]]
[[Image:EVHV_25.gif|none]]
, one displays the following dialog. Two main type of machine are configurable: PMSM machines and SCIM machines.
, one displays the following dialog. Two main type of machine are configurable: PMSM machines and SCIM machines.


[[Image:EVHV_26.png|framed|none]]
[[Image:EVHV_26.png|none]]


One can this configuration in the workbook of the project by pressing SAVE. After the SAVE the eMarkers tab opens automatically.
One can this configuration in the workbook of the project by pressing SAVE. After the SAVE the eMarkers tab opens automatically.
Line 146: Line 146:
===eMarkers===
===eMarkers===
The eMarkers associated to the eMachine can be displayed by clicking on the following icon
The eMarkers associated to the eMachine can be displayed by clicking on the following icon
[[Image:EVHV_27.png|framed|none]]
[[Image:EVHV_27.png|none]]
. From the table one can apply the eMarkers to the relevant graphs (spectra, spectrograms, spatiograms).
. From the table one can apply the eMarkers to the relevant graphs (spectra, spectrograms, spatiograms).


[[Image:EVHV_28.png|framed|none]]
[[Image:EVHV_28.png|none]]


One can select them to be displayed in the graphs or not by activating/inactivating the VIEW checkbox.
One can select them to be displayed in the graphs or not by activating/inactivating the VIEW checkbox.
Line 173: Line 173:
{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|align = "center"|
|align = "center"|
[[Image:EVHV_29.png|framed|none]]
[[Image:EVHV_29.png|none]]


|Sensors positions
|Sensors positions
Line 180: Line 180:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_30.png|framed|none]]
[[Image:EVHV_30.png|none]]


|Select inputs
|Select inputs
Line 187: Line 187:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_31.png|framed|none]]
[[Image:EVHV_31.png|none]]


|Load
|Load
Line 194: Line 194:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_32.png|framed|none]]
[[Image:EVHV_32.png|none]]


|Post analyze
|Post analyze
Line 201: Line 201:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_33.gif|framed|none]]
[[Image:EVHV_33.gif|none]]


|Select measurement
|Select measurement
Line 208: Line 208:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_34.gif|framed|none]]
[[Image:EVHV_34.gif|none]]


|Scale on Max
|Scale on Max
Line 215: Line 215:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_35.gif|framed|none]]
[[Image:EVHV_35.gif|none]]


|Scale on Displayed
|Scale on Displayed
Line 222: Line 222:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_36.png|framed|none]]
[[Image:EVHV_36.png|none]]


|Windows configuration
|Windows configuration
Line 229: Line 229:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_37.png|framed|none]]
[[Image:EVHV_37.png|none]]


|Reference spectrogram selection
|Reference spectrogram selection
Line 236: Line 236:
|-
|-
|align = "center"|
|align = "center"|
[[Image:EVHV_38.png|framed|none]]
[[Image:EVHV_38.png|none]]


|Spatiogram selection
|Spatiogram selection
Line 245: Line 245:
===Sensors positions===
===Sensors positions===
To allow for spatiograms display the sensors positions need to be defined. This is achieved through the "Sensors Positions Editor" <nowiki>[</nowiki>
To allow for spatiograms display the sensors positions need to be defined. This is achieved through the "Sensors Positions Editor" <nowiki>[</nowiki>
[[Image:EVHV_39.png|framed|none]]
[[Image:EVHV_39.png|none]]
<nowiki>]</nowiki> as displayed below.
<nowiki>]</nowiki> as displayed below.


[[Image:EVHV_40.png|framed|none]]
[[Image:EVHV_40.png|none]]


The node defined in this window need to be the same ones as the ones used in the input<nowiki>'</nowiki>s configuration.
The node defined in this window need to be the same ones as the ones used in the input<nowiki>'</nowiki>s configuration.
Line 256: Line 256:
===Displaying Spatiograms===
===Displaying Spatiograms===
Spatiograms are displayed by first selecting the measurement using <nowiki>[</nowiki>
Spatiograms are displayed by first selecting the measurement using <nowiki>[</nowiki>
[[Image:EVHV_41.gif|framed|none]]
[[Image:EVHV_41.gif|none]]
<nowiki>]</nowiki> and selecting the desired wavenumbers using <nowiki>[</nowiki>
<nowiki>]</nowiki> and selecting the desired wavenumbers using <nowiki>[</nowiki>
[[Image:EVHV_42.png|framed|none]]
[[Image:EVHV_42.png|none]]
<nowiki>]</nowiki>. Spatiograms are all displayed with a blue background to distinguish them specifically from the Spectrograms.
<nowiki>]</nowiki>. Spatiograms are all displayed with a blue background to distinguish them specifically from the Spectrograms.


Line 265: Line 265:
In order to fully use the content of the Spatiograms, one should apply the markers on the spatiograms and open the section using the left bottom cross. If the spatiogram contain eMarkers the bottom left section will show the profiles of the eMarkers.
In order to fully use the content of the Spatiograms, one should apply the markers on the spatiograms and open the section using the left bottom cross. If the spatiogram contain eMarkers the bottom left section will show the profiles of the eMarkers.


[[Image:EVHV_43.png|framed|none]]
[[Image:EVHV_43.png|none]]


''Showing all eMarkers contained in Spatiogram 0''
''Showing all eMarkers contained in Spatiogram 0''


[[Image:EVHV_44.png|framed|none]]
[[Image:EVHV_44.png|none]]


''Selecting all active eMarkers contained in Spatiogram 0''
''Selecting all active eMarkers contained in Spatiogram 0''
Line 277: Line 277:
{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|One can grab the cursor in each of the section to position it at the right frequency or right RPM (or time).<br>The spatiograms will follow the preferences setup for the colormaps (dB by default). It can also be displayed as a 3D graph if desired <nowiki>[</nowiki>Lin by default<nowiki>]</nowiki>. As described earlier, and as the EVHV module is integrated in NVGate, it will benefit of all NVGate standard functions. For more details the NVGate user<nowiki>'</nowiki>s manual should be consulted.<br>
|One can grab the cursor in each of the section to position it at the right frequency or right RPM (or time).<br>The spatiograms will follow the preferences setup for the colormaps (dB by default). It can also be displayed as a 3D graph if desired <nowiki>[</nowiki>Lin by default<nowiki>]</nowiki>. As described earlier, and as the EVHV module is integrated in NVGate, it will benefit of all NVGate standard functions. For more details the NVGate user<nowiki>'</nowiki>s manual should be consulted.<br>
[[Image:EVHV_45.png|framed|none]]
[[Image:EVHV_45.png|none]]


|align = "center"|<br>''Order profile cursor''
|align = "center"|<br>''Order profile cursor''
Line 291: Line 291:
The help section allows to access 2 main features.
The help section allows to access 2 main features.


[[Image:EVHV_46.png|framed|none]]
[[Image:EVHV_46.png|none]]
This icon allows to start the EVHV module user<nowiki>'</nowiki>s manual
This icon allows to start the EVHV module user<nowiki>'</nowiki>s manual


[[Image:EVHV_47.png|framed|none]]
[[Image:EVHV_47.png|none]]
This icon allows to display the "About …" information
This icon allows to display the "About …" information


The EVHV module has been developed thanks to a cooperation between OROS and EOMYS who is specialist in Electromagnetic Noise and Vibration. Credits to EOMYS are given in this About dialog.
The EVHV module has been developed thanks to a cooperation between OROS and EOMYS who is specialist in Electromagnetic Noise and Vibration. Credits to EOMYS are given in this About dialog.


[[Image:EVHV_48.gif|framed|none]]
[[Image:EVHV_48.gif|none]]


''The About section''
''The About section''
Line 311: Line 311:
* If further assistance is needed, the Customer Care Team can be contacted using the information provided on the following link : [https://www.oros.com/services/support/ https://www.oros.com/services/support/]
* If further assistance is needed, the Customer Care Team can be contacted using the information provided on the following link : [https://www.oros.com/services/support/ https://www.oros.com/services/support/]


[[Image:EVHV_49.png|framed|none]]
[[Image:EVHV_49.png|none]]


''The OROS Customer Care team''
''The OROS Customer Care team''


[[category:EVHV]]
[[category:EVHV]]

Revision as of 12:38, 27 April 2020

Introduction and overview

Objectives

The objective of the EVHV module is to characterize the electromagnetic forces which are responsible of the noise emission of an electric motor. In particular it will be achieved through 2 main steps:

  • eFrequencies determination and displays: they represent the characteristic frequencies that one may expect to find in the spectra. They are based on the specificities of the motor and depend of the RPM. For this reason, they are defined as harmonics.
  • Spatiograms analysis and displays. Spatiograms are calculated based on measurements of accelerometers data distributed around the surface of the motor stator as shown in the picture below.
EVHV 01.gif

Sensors positioned for Spatiograms analysis

Each spatiogram is representative of a spatial distribution of the Electromagnetic forces. The sum of the participation of each spatiogram lead to the global vibration response. Determining the spatiogram responsible of the vibration harmonic that should be decreased is one of the major objectives of the EVHV module.

EVHV 02.png

Separation of the response in a sum of participating wavenumbers

Getting started tutorial

The following tutorial is based on a provided project called "EVHV App Z12p2". To follow the steps below, one should preliminary place this project in the NVGate projects directory. When starting NVGate the following window will display. One should open a project and select "EVHV App Z12p2". This chapter is meant to provide a first global approach so to go through the main steps.

Open the project and load setup

EVHV 03.gif

Open project

EVHV 04.gif

Load Setup, last saved in project

The setup contains 2 layouts: Spectra and Spatio

EVHV 05.png

Display layout 1 called Spectra

Checking the eFrequencies

EVHV 06.png

EV/HV ribbon

eMachine should be clicked to access to the following dialog. At this stage, one can select the main characteristics of the eMotor.

EVHV 07.gif

Machine definition

When the machine is configured, one can press Save. The user goes automatically to the following dialog which is the "eMarkers" one.

EVHV 08.png

eMarkers table

When pressing "Apply" the eMarkers will be displayed on the graphs of the current layout.

EVHV 09.png

Spectra with the eMarkers

The eMarkers dialog should be closed by clicking on the cross on the top right hand-side.

Change the Layout to reach layout2 (called Spatio). Changing layout can be achieved by clicking on

EVHV 10.png

which is located in the "Measurement" tab. A keyboard shortcut also exists: [CTRL+SPACE]

Displaying spatiograms

EVHV 11.png

Icons linked to the display of the spatiograms

By opening the

EVHV 12.png

positions editor, one can check the positions that were saved in the setup

EVHV 13.png

The next step is to select a measurement. In the provided project and its contained measurement, spatiograms are already calculated. One should press the icon "select measurement" as shown below. In the dialog that follows, one should type, in the filtering area: for example, Z12. This will allow to find easily the appropriate measurement.

EVHV 14.png

Selecting a measurement

From that point, the spatiograms for all wavenumbers (one spatiogram for each wavenumber) will be loaded and displayed. If they are not already calculated (as it is the case of the provided project).

EVHV 15.png

Loading the Spatiograms

Following that action, the spatiograms are automatically scaled and displayed as follows.

EVHV 16.png

Spatiograms displays

  • The spatiograms are displayed here using the 3*3 configuration.
  • The left top window is a reference spectrogram, the others are spatiograms
  • The spatiograms automatically scaled using by default the "scale on max display option". It takes the Max of all results and set it as the maximum value of the scale.
  • We want now to find the participating wavenumbers to certain harmonic which are of interest: As an example, we want to know what are the participating wavenumbers to H12 (Index 3). We see that the wavenumber 0 is clearly the highest contributor to H12.
  • Applying the eMarkers, confirms emarker3 placed on the spatiogram thanks to the eMarkers.
EVHV 17.png

Applying eMarkers to the Spatiograms

When using the displays:

  • The windows configuration can be changed using
EVHV 18.gif
  • The scaling can be updated using the Scale on Max
EVHV 19.png

or the scale on displayed

EVHV 20.png
  • The reference spectrogram (after selecting it) can be changed by using
EVHV 21.gif
  • The wavenumber for each spatiogram can be changed by using
EVHV 22.png

eFrequencies: from eMachine setup to eMarkers display

There are 2 main steps in the determination of the eFrequencies: the machine description achieved through the eMachine tab [

EVHV 23.gif

] and the eMarkers tab [

EVHV 24.png

] where the eFrequencies are calculated.

eMachine

By clicking on

EVHV 25.gif

, one displays the following dialog. Two main type of machine are configurable: PMSM machines and SCIM machines.

EVHV 26.png

One can this configuration in the workbook of the project by pressing SAVE. After the SAVE the eMarkers tab opens automatically.

One can load an eMachine by pressing Load. When opening a project with its associated workbook, the eMachine saved in the workbook of that project will be automatically loaded.

The configuration parameters depend on the type of machine: they can be seen from the above windows

eMarkers

The eMarkers associated to the eMachine can be displayed by clicking on the following icon

EVHV 27.png

. From the table one can apply the eMarkers to the relevant graphs (spectra, spectrograms, spatiograms).

EVHV 28.png

One can select them to be displayed in the graphs or not by activating/inactivating the VIEW checkbox.

When displaying eMarkers for a SCIM machine, one should setup the SLIP as well (between 0 and 1).

The tooltip of each eMarker will provide more detail about the eMarker. To see it, the eFrequencies editor needs to be active and one needs to hold the mouse one second over the harmonic.

One should read the table using the following notations:

  • H: Harmonics of the rotating speed
  • f: frequency
  • fs: electric stator frequency
  • r: wavenumbers

Spatiograms: from acquisition to display

Spatiograms allow to evaluate the contribution of each wavenumber to the vibration response. This is done by comparing all the spatiograms to one reference spectrogram. Spatiograms are calculated offline based on Instant spectra waterfalls using the motor RPMs or time as z axis reference. If the spatiograms are not contained in the project, they are automatically calculated when selecting the measurement.

In the spatiograms ribbon area the following actions can be achieved:

EVHV 29.png
Sensors positions Allows to specify the positions of the accelerometers used to measure and calculate the spatiograms
EVHV 30.png
Select inputs Allows to access the inputs configuration. This is used to setup the instrument to acquire the data required to calculate the spatiograms
EVHV 31.png
Load Allows to load a measurement setup. One can for example reload a measurement setup which was used for a previous measurement.
EVHV 32.png
Post analyze Allows to post analyze a signal that was recorded
EVHV 33.gif
Select measurement Allows to select the measurement containing the results. If the measurement already contains the spatiograms, they will be displayed. Otherwise they will be recalculated.
EVHV 34.gif
Scale on Max Allows to rescale all spatiograms with the same Max scale. This max scale is the Max value contained in all spatiograms. This icon is available when a spatiogram is active. It is greyed when a reference spectrogram is active.
EVHV 35.gif
Scale on Displayed Allows to rescale all spatiograms with the same Max scale. This max scale is the Max value contained in all the displayed spatiograms. This icon is available when a spatiogram is active. It is greyed when a reference spectrogram is active.
EVHV 36.png
Windows configuration Allows to choose the windows configurations. It also allows to refresh the display
EVHV 37.png
Reference spectrogram selection Allows to select the reference spectrogram to be displayed. The associated node is also shown as "Ref: [input label]: node number". This icon is only active when the spectrogram window is active
EVHV 38.png
Spatiogram selection Allows to select the spatiogram to be displayed by selecting its associated wavenumber. This icon is only active when the spectrogram window is active

Sensors positions

To allow for spatiograms display the sensors positions need to be defined. This is achieved through the "Sensors Positions Editor" [

EVHV 39.png

] as displayed below.

EVHV 40.png

The node defined in this window need to be the same ones as the ones used in the input's configuration.

The sensors position setup can be saved in the project workbook using the save button. It can be reloaded using the load button. When loading the project and its associated setup it is loaded as well.

Displaying Spatiograms

Spatiograms are displayed by first selecting the measurement using [

EVHV 41.gif

] and selecting the desired wavenumbers using [

EVHV 42.png

]. Spatiograms are all displayed with a blue background to distinguish them specifically from the Spectrograms.

A shortcut allows to easily change wavenumbers: one should select the spatiogram to be modified and use [CTRL]+ [up and down arrows].

In order to fully use the content of the Spatiograms, one should apply the markers on the spatiograms and open the section using the left bottom cross. If the spatiogram contain eMarkers the bottom left section will show the profiles of the eMarkers.

EVHV 43.png

Showing all eMarkers contained in Spatiogram 0

EVHV 44.png

Selecting all active eMarkers contained in Spatiogram 0

The order section cursor is also active and can be used to compare eMarkers section to other order sections

One can grab the cursor in each of the section to position it at the right frequency or right RPM (or time).
The spatiograms will follow the preferences setup for the colormaps (dB by default). It can also be displayed as a 3D graph if desired [Lin by default]. As described earlier, and as the EVHV module is integrated in NVGate, it will benefit of all NVGate standard functions. For more details the NVGate user's manual should be consulted.
EVHV 45.png

Order profile cursor

Links

The links group allows to add any additional dedicated module which would be optionally written as a macro or an external program. It should be placed in the LINKS directory of NVGate. If done so, it will appear in the list.

  • Selection of an external application or macro to be started
  • Execute the application

Help

The help section allows to access 2 main features.

EVHV 46.png

This icon allows to start the EVHV module user's manual

EVHV 47.png

This icon allows to display the "About …" information

The EVHV module has been developed thanks to a cooperation between OROS and EOMYS who is specialist in Electromagnetic Noise and Vibration. Credits to EOMYS are given in this About dialog.

EVHV 48.gif

The About section

Contact us

This user's manual aims at providing the most complete information to help user's obtaining the most efficient use of the product. However, if complementary information is required there are various ways to contact OROS.

  • First, OROS relies on a worldwide network of authorized representatives. OROS products and services are marketed worldwide in more than 35 countries.

Your local reseller can be found at https://www.oros.com/find-us/.

The OROS Customer Care team