</font>==How to install the single/dual plane balancing module==
===Equipment required for the installation:===
* Before proceeding to the Balancing installation, NVGate should be installed (Refer to NVGate User<nowiki>'</nowiki>s Manual).
* Software CD containing OROS Balancing and the online help.
* A dongle dedicated to OROS Balancing software (in case of ORNVS-BAL-FL)
===Software licensing===
====Standard license: ORNVS-BAL-ST====
If you are using a standard license, the OROS hardware (OROS 3-Series analyzers) is used to allow the software operation. Your selected OROS analyzer should be connected when using the balancing solution.
For the standard license, your hardware keys should be updated. If it the case, use the delivered CD to update your hardware key. For details about this procedure, refer to your Analyzer installation guide.
====Floating license: ORNVS-BAL-FL====
If you are using a floating license, you should plug your USB balancing dongle when using the software (online or offline). The floating license will allow you to use your balancing software on any of your analyzers.
For the floating license, an updating of your hardware keys may be required. If it the case, use the delivered CD to update your hardware key. For details about this procedure, refer to your Analyzer installation guide.
===Software installation===
In order to install the OROS Balancing solution, start the setup.exe from the CD ROM. Then, follow the installation procedure as described below:
The following screen will appear: press OK to continue the installation.
[[Image:Balancing_02.jpg|framed|none]]
''Installation procedure start''
The software installation proposes you to choose your installation directory based on the following window. If the default directory is satisfying, press the icon showing a computer.
[[Image:Balancing_03.jpg|framed|none]]
''Installation directory selection''
At the next stage, you can choose the position of the shortcut in the Windows START menu. If the default path is satisfying press continue.
[[Image:Balancing_04.jpg|framed|none]]
''Start Menu path selection''
The installation process is now finished. You can now press OK from the following dialog box.
[[Image:Balancing_05.jpg|framed|none]]
''Installation process completion''
You can now start the Balancing solution from your '''WINDOWS START Menu.'''
----
<font color="#4F81BD"><font size = "6">Single / Dual PLANE<br>Balancing<br><br>User<nowiki>'</nowiki>s Manual</font></font>
----


==Introduction==
==Introduction==
A rotor is a body rotating about its axis during service. In general such a rotor consists of an axle with one or more discs fitted to the axle. Such discs can be fly wheels, grinding wheels, or turbine wheels etc. The axle running in bearings allows thus the rotation of the body.
A rotor is a shaft rotating around its axis during service. In general, such a rotor consists of a shaft with one or more discs fitted to the axle. Such discs can be fly wheels, grinding wheels, turbine wheels, etc. The shaft is usually running in bearings allowing the rotation of the body. Depending on their rotational speed, two basic categories can be defined to classify rotors: <u>rotors with rigid shaft</u>, and <u>rotors with flexible shaft</u>. <br>
<br>
If the operating speed remains below half of the first critical bending speed, the shaft does not deflect : it may be considered as a rotor with a rigid shaft. At such operational speeds and due to the non circular cross section of the rotor, the axis of rotation (Z) and the inertial axis (&Delta;) does not coincide (e.g. the mass is not evenly dispatched in a section of the shaft). This may results in a tumbling movement of the structure, this amplitude depends on the bearing clearance and stiffness. In any case, the bearings are subjected to unnecessary or even not allowed loads.  


Depending on their rotational speed, rotors can be grouped in two basic categories: <u>rotors with rigid shaft</u>, and <u>rotors with flexible shaft</u>. If the operating speed remains below half of the first critical bending speed, the body does not deflect. At such operation speeds and non circular cross section of the shaft and / or rotor, the axis of rotation and the inertial axis do not coincide. This results in a tumbling movement of the structure, the size of which depends on the bearing clearance and stiffness. In any case the bearings are subjected to unnecessary or even non allowed loads. At higher speeds the shaft will deflect, due to the non symmetric circular cross section. Depending on the position of the discs on the shaft they can even be inclined and thus increase the whirl.
[[Image:Unbalanced_shaft_schem.png|framed|center|''Unbalance : Inertial axis does not coincide with rotational axis.<br> The unevenly mass distribution is represented by "m"'']]<br>


An increase of the running quality is achieved through reduction of the asymmetry by means of addition or reduction of masses. Thus the inertial axis approaches the rotational axis. Rigid rotors can be sufficiently balanced in one or two planes. In practice depending of the number of transducers used and the number of planes four cases can be considered.
At higher speeds the shaft will deflect, due to is own stiffness. In that case, it might be considered as a rotor with flexible shaft.  Depending on the position of the discs on the shaft they can even be inclined and thus create an oil whirl. In that case, the Multiplane Balancing solution must be used.<br>
<br>
An increase of the running quality is achieved through reduction of the asymmetry by means of local addition or reduction of mass. Thus the inertial axis is moved to approach the rotational axis. Rigid rotors can be sufficiently balanced in one or two planes. In practice depending of the number of transducers used and the number of planes four cases can be considered.


{|border="2" cellspacing="0" cellpadding="4" width="93%"
{|border="2" cellspacing="0" cellpadding="4" width="93%"
Line 115: Line 49:




{|border="0" cellspacing="2" width="100%"
{|border="2" cellspacing="4" width="90%"
|Case 1  
|Case 1  
|colspan = "2"|The simplest case is to use one vibration transducer fitted for example to the rotor housing near one bearing in radial direction.
|The simplest case is to use one vibration transducer fitted for example to the rotor housing near one bearing in radial direction.


|-
|-
|Case 2  
|Case 2  
|&nbsp;
|For two planes fit one transducer near each bearing in radial direction, as above.
|For two planes fit one transducer near each bearing in radial direction, as above.


Line 147: Line 80:
'''Accelerometer'''
'''Accelerometer'''


The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example in '''Sketch 1,''' the <font color="#FF0000">'''angular correction''' </font>is '''90°''' and the <font color="#339966">'''offset''' </font>is -'''15 °'''.
The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example, in '''Sketch 1,''' the '''angular correction''' </font>is '''90°''' and the <font color="#339966">'''offset''' </font>is -'''15 °'''.


'''Tip'''
'''Tip'''
Line 187: Line 120:


===Physical Background===
===Physical Background===
The <u>initial run</u> analyses the behavior of the rotor due to its initial unbalance.
The <u>initial run</u> analyzes the behavior of the rotor due to its initial unbalance.


During the <u>test run</u>, the applied test masses modify the position of the unbalance. This yields the sensitivity of the rotor. Thus with the knowledge of the reaction of the rotor to added masses, suitable masses can be calculated to compensate the initial unbalance.
During the <u>test run</u>, the applied test masses modify the position of the unbalance. This yields the sensitivity of the rotor. Thus with the knowledge of the reaction of the rotor to added masses, suitable masses can be calculated to compensate the initial unbalance.


For <u>balancing in one plane</u>, just one test mass and one test run is necessary. It is important that the angular position of the initial unbalance is changed   significantly by the test mass. Take this into account, when choosing test weight and position.
For <u>balancing in one plane</u>, just one test mass and one test run is necessary. It is important that the angular position of the initial unbalance is changed significantly by the test mass. Take this into account when choosing test weight and position.


When <u>balancing in two planes</u>, two test runs are necessary. For each run only one test mass is necessary positioned in one of both planes respectively. Again in both test runs the position of the unbalance must be changed by the test masses.
When <u>balancing in two planes</u>, two test runs are necessary. For each run only one test mass is necessary to be positioned in one of both planes respectively. Again, in both test runs the position of the unbalance must be changed by the test masses.


'''Assumptions'''
'''Assumptions'''
Line 201: Line 134:
'''Example'''
'''Example'''


Imagine a rotating machine to be balanced when standing untightened on the floor. After the test mass is mounted the increased unbalance       causes the machine to move. Holding or fixing the machine during the test run will cause wrong balancing results. To overcome this chose lower test mass or position to reduce the unbalance. If this doesn<nowiki>'</nowiki>t work you could fix the machine during the <u>complete</u> balancing procedure. After this basic balancing execute a second complete balancing procedure with the machine unfixed (in normal operating conditions).
Imagine a rotating machine to be balanced when standing untightened on the floor. After the test mass is mounted the increased unbalance causes the machine to move. Holding or fixing the machine during the test run will cause wrong balancing results. To overcome this you must choose a lower test mass or position to reduce the unbalance. If this doesn<nowiki>'</nowiki>t work you could fix the machine during the <u>complete</u> balancing procedure. After this basic balancing, execute a second complete balancing procedure with the machine unfixed (in normal operating conditions).


'''General advice'''
'''General advice'''
Line 220: Line 153:
The '''OROS Single / Dual Balancing module '''appears with the following start screen
The '''OROS Single / Dual Balancing module '''appears with the following start screen


[[Image:Balancing_01.png|framed|none]]
[[Image:Bal_start.png|framed|none]]
 
[[Image:Balancing_08.png|framed|none]]


''Start Balancing Solution of rigid rotors''
''Start Balancing Solution of rigid rotors''


Choose your preferred language start the Software by clicking
- "Online" to start measurements, lunching NVGate.
 
- "Online" to start measurements.


- "Offline" to run the software offline.
- "Offline" to run the software offline.


When starting online the system will require starting NVGate displaying the dialog window below.
- "Setup" to enter in the parameters of Balancing (selection of the language and location of NVGate.exe).


[[Image:Balancing_09.png|framed|none]]
- "Standard" mode : Full access to the software


''NVGate start request''
- "Restricted" mode : Restricted access (do not allow to create a new project)


Start NVGate by click on the NVGate Icon below.
When starting online the system automatically start NVGate, while displaying the dialog window below.


[[Image:Balancing_10.png|framed|none]]
[[Image:Connect_Analyser.png|framed|none]]


''NVGate icon''
''NVGate start request''
 
If the hardware or dongle is not connected, '''NVGate''' will detect this error and quit it with the following message.
 
[[Image:Balancing_11.png|framed|none]]
 
''Ensure either the hardware or the dongle is connected''


Then, select the running mode.
Then, select the running mode.


[[Image:Balancing_12.png|framed|none]]
[[Image:Connection.png|framed|none]]


''Select running mode''
''Select the NVGate mode''


* To proceed to a measurement, select: "Connection to hardware"
* To proceed to a measurement, [[NVGate_Software_overview#Starting_the_analyser_and_NVGate|start NVGate in "Connected mode"]]
* For Offline access the "Office mode" can also be used.
* For Offline access the "Office mode" can also be used.
* When the software starts the following NVGate window is displayed. Minimize NVGate.
* When the software starts, the NVGate software is displayed. Minimize NVGate.
 
[[Image:Balancing_13.gif|framed|none]]


* ''NVGate - Start<nowiki>'</nowiki>n Go''
* ''NVGate - Start<nowiki>'</nowiki>n Go''
Line 266: Line 187:


==Settings==
==Settings==
Settings follow the same rules whether it is for one plane balancing (single) or two planes balancing (dual). The description below is given for the two planes balancing. For one plane, the description would be the same but with one plane.
Settings follow the same steps whether it is for one plane balancing (single) or two planes balancing (dual). Thus, description below is given for the balancing of a two planes rotor.  


====Project management====
====Project management====
To create a new project click on <u>'''N'''</u>'''ew''' or load one of the existing projects after selection <u>'''O'''</u>'''K'''.
=====Project Manager window=====
 
=====Load an existing Project=====


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|<font color="#FF0000">'''(1)''' </font>Select the Hard disc partition (for example C)<br>'''(2)''' Select the sub directory (for example OROS Balancing Solution)<br>'''(3)''' Select the Project in the Project List (for example Rotor 3)
|'''(1) Project Base : '''List of the project in the current Project Base<br>'''(2) Projects Base Path :'''Change the Project Base<br>'''(3) Project Browse : ''' Add project in the current Base.
|'''(4)''' Selected Project Rotor 3<br>'''(5)''' Click to start the program with the selected project
|'''(4) New Project :''' Create a new project<br>'''(5) Exit :''' Exit the balancing program


|}
|}


[[Image:Balancing_14.png|framed|none]]
[[Image:Bal_Proj_Manager.png|framed|none]]


''Load a Project''
=====Load an existing Project=====


----
To load an existing project, select the project in the '''(1) Project Base''' and click OK.
 
You can import a project form another database by clicking on '''(3) Browse Project'''.


=====Create a new Project=====
=====Create a new Project=====
'''Step 1'''
To create a new project, click on '''(4) New Project''' and enter the name of the project in the appearing ribbon at the bottom of the window :
[[Image:New_Proj.png|framed|none]]<br>


<font color="#FF0000">'''(1) '''</font>Click to open the explorer,<font color="#FF0000">''' (2)''' </font>In the Explorer, <font color="#FF0000">'''(3)''' </font>click to open a new sub directory
The new project will then appear in the Project Base, select it and click OK :


<font color="#FF0000">'''(4)''' </font>Rename the new sub directory to "Machine" and double click to change into the new subdirectory
[[Image:New_Proj2.png|framed|none]]<br>


[[Image:Balancing_15.png|framed|none]]
====Select the configuration of the machine====
This window, called "Analyser", will help you to quickly setting up your measurement.


''Project generation''
First, select the configuration of your machine according to the number of planes, the geometry of the rotor (pos. of planes and bearings) and the number of vibration sensors.


'''Step 2:'''
[[Image:Bal_Select_Machine.png|framed|none|''Balancing Planes Setup – 2 Planes and 2 Sensors'']]<br>


<font color="#FF0000">'''(1)''' </font>Sub directory Machine <font color="#FF0000">'''(2)''' </font>Enter project name Engine A <font color="#FF0000">'''(3)''' </font>Click to save the new project
Here, we are selecting a two planes rotor, with both planes between the bearings and 2 sensors.


[[Image:Balancing_16.png|framed|none]]
Connect your transducers to the corresponding inputs on your 3-SERIES analyzer. The Balancing program will automatically associates the physical inputs of the frontend with the channels for the balancing according to the drawing : ''In1'' is the '''channel 1''' of the frontend, ''In2'' is the '''channel 2''', ''In3'' the '''channel 3''' and ''In4'' the '''channel 4'''.


''Project generation''
====Dynamical Channels settings====
Once you have selected the correct type of machine and connected the sensors to the frontend, you may go in the "Input" Tab to set your channels.


'''Step 3: Load the new Project'''
[[Image:Bal_Dyn_Chann.png|framed|none]]


<font color="#FF0000">''' (1)''' </font>Change the directory to "Machine" sub directory
''Adjustment of channels''


'''(2)''' Project List Engine A
Set the [[NVGate_Front_End#Inputs|input range]] and the [[NVGate_Front_End#Inputs|coupling]] for your transducer, as well as his unit and sensitivity and physical quantity. You may also set the [[NVGate_Front_End#Inputs_settings|Sampling rate]] according to the maximal Rotating speed of the shaft (The sampling rate must be higher than the double of the max RPM*60).


'''(3)''' Selection Engine A
To choose your transducer from the transducer data base, click on '''Transducer'''.


'''(4)''' Click to start the program with the new Project Engine A
====Transducer database====


[[Image:Balancing_17.png|framed|none]]
[[Image:Balancing_22.png|framed|none]]


''Project generation''
''Transducer data base''


====Activation of measurement channels====
For easier and faster adjustment use the transducer data base.
Depending on the number of balancing planes and sensors used, one, two or four channels are needed.


Choose what you need for your measurement, by clicking on '''A, B, C''' or '''D''' or use the following shortcuts: <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>A<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>B<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>C<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>D<nowiki>]</nowiki>
Input your transducer in the list shown by clicking the corresponding fields and adjust an input transducer label, unit and sensitivity.


The corresponding channels are activated. This is shown by a <font size = "5">''''''</font> on the corresponding BNC connector in the Figure.
To select a transducer click in the corresponding line, and choose the analyzer channel, where this transducer is connected to. Click '''Set.'''


Connect your transducers to the corresponding In-puts on your 3-SERIES analyzer.
The transducer data base can be saved and reloaded.


The Tach signal must be connected to Ext. sync. 1
It is also possible to create several data bases for example for different users and their transducers.


<u>Example</u>
====Setting the tachometer====


<font color="#FF0000">'''(1)''' </font>Click on <u>C</u> for two Planes and two Sensors
To set the tachometer, you need to go into the "Speed" tab :
   
[[Image:Bal_Tacho.png|framed|none]]


'''(2)''' Channel    1 is activated  <font size = "4">''''''</font>
'''Note: '''Your tach signal must have one pulse per revolution. If you have more than one pulse, you can set the maximal speed as Real_speed*Pulse/rev.


'''(3)'''  Ext. sync. 1 is activated 
* Set the range, coupling and slope for this tach signal.
[[Image:Balancing_18.png|framed|none]]
* Input the balancing speed.
 
* Set the number of averages for your measurements.
'''(4)'''  To continue click on <u>'''O'''</u>'''K'''
 
Or use      '''<nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>O<nowiki>]</nowiki>'''
 
[[Image:Balancing_19.png|framed|none]]
 
''Balancing Planes Setup – 2 Planes and 2 Sensors''
 
====Channels settings====
Activated channels are highlighted in green. Channels 1 and 2 and Ext. sync.1 are activated.
 
[[Image:Balancing_20.png|framed|none]]


''Adjustment of channels''
====Set a phase adjustment====


Set the input range and the coupling for your transducer, as well as his unit and sensitivity.
To set a phase adjustment, you can specify the position of the sensors. To enter the menu, click on "Position":


To choose your transducer from the transducer data base, click on '''Transducer'''.
[[Image:Bal_Position.png|framed|none]]<br>


'''Notice: '''Your tach signal must have one pulse per revolution.
The position of each sensors and the tachometer can be set :  
[[Image:Bal_Position_Menu.png|framed|none]]<br>


* Set the range, coupling and slope for this tach signal.
'''Note :''' The 0° position is the position of the tachometer reflector on the shaft. The angle are counted positive in the anti-rotation direction.
* Choose the speed range in which you want to observe your rotor.
* Input the balancing speed.
* Set the number of averages for your measurements.
* An eventually needed phase correction can be introduced here. See chapter '''1 Introduction'''.
* Choose an appropriate sampling frequency.
* All adjustments can be saved and reloaded


[[Image:Balancing_21.png|framed|none]]
====Saving the channel and measuring setup====


''Saving the channel and measuring setup''
All setup settings can be saved and reloaded with "<u>S</u>ave" and "<u>L</u>oad" buttons.<br>


All setup settings can be saved and reloaded.
'''Note:'''  '''The balancing module''' always starts with the last analyzer settings used.<br>


'''Notice:'''  '''The balancing module''' always starts with the analyzer settings that have been used last.
You do not need to do all adjustments for a new project. Just load the setup of an existing project.<br>


You do not need to do all adjustments for a new project. Just load the setup of an existing project.
'''Tip:'''<br>


'''Tip:'''
If you want to make sure you always start with the same settings, create a reference project with all settings adjusted properly. Each part of the project is saved with a specific extension.
 
If you want to make sure, you always start with the same settings, create a reference project with all settings adjusted properly. Each part of the project is saved with a specific extension.


* Reference Project =  *.WSR
* Reference Project =  *.WSR
Line 389: Line 295:
For a new Project with these Settings: Load Reference Project.
For a new Project with these Settings: Load Reference Project.


This is now the last project that has been used
This is now the last project that has been used:


* Create New Project: It has the settings of the Reference Project.
* Create New Project: It has the settings of the Reference Project.
Line 396: Line 302:


* Click "Continue" to proceed to the next step.
* Click "Continue" to proceed to the next step.
====Transducer database====
[[Image:Balancing_22.png|framed|none]]
''Transducer data base''
For easier and faster adjustment use the transducer data base.


Input your transducer in the list shown by clicking the corresponding fields and adjust an input transducer label, unit and sensitivity.
To select a transducer click in the corresponding line, and choose the analyzer channel, where this transducer is connected to. Click '''Set.'''
The transducer data base can be saved and reloaded.
It is also possible to create several data bases for example for different users and their transducers.


----
----


====Rotor geometry and balancing quality====
====Rotor geometry and balancing quality====
<u>Example</u>


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|<font color="#FF0000">'''(1)''' </font>No. of mass positions Enter 12 for both planes<br>'''(2)''' Radius 100 <nowiki>[</nowiki>mm<nowiki>]</nowiki> <br>''' (3)''' Offset     15 <nowiki>[</nowiki>Deg<nowiki>]</nowiki><br>'''(4)'''  Click on Apply to display the circle<br>'''(5)'''  Unit of Unbalance <nowiki>[</nowiki>g mm<nowiki>]</nowiki> or <nowiki>[</nowiki>oz in<nowiki>]</nowiki>
|'''(1)''' No. of mass positions both planes<br>'''(2)''' Radius for both planes<nowiki>[</nowiki>mm<nowiki>]</nowiki> <br>''' (3)''' Offset of the first mass position regarding the reference at 0°  <nowiki>[</nowiki>Deg<nowiki>]</nowiki><br>'''(4)'''  Click on Apply to display the circle<br>'''(5)'''  Unit of Unbalance <nowiki>[</nowiki>g mm<nowiki>]</nowiki>, <nowiki>[</nowiki>oz in<nowiki>]</nowiki> or <nowiki>[</nowiki>g in<nowiki>]</nowiki>
|'''(6)'''  Rotor mass<br>'''(7)'''  Speed RPM<br>'''(8)'''  Quality class<br>'''(9)''' Residual unbalance <nowiki>[</nowiki>g mm<nowiki>]</nowiki><br>'''(10)'''  Residual unbalance <nowiki>[</nowiki>oz in<nowiki>]</nowiki>
|'''(6)'''  Rotor mass<br>'''(7)'''  Speed RPM<br>'''(8)'''  Quality class (def. in ISO1940/1)<br>'''(9)''' Maximal residual unbalance (according to ISO1940) <nowiki>[</nowiki>g mm<nowiki>]</nowiki><br>'''(10)'''  Residual unbalance <nowiki>[</nowiki>oz in<nowiki>]</nowiki>


|}
|}


[[Image:Balancing_23.png|framed|none]]
[[Image:Bal_Rotor_Quality.png|framed|none]]


''Rotor geometry and balancing quality''
''Rotor geometry and balancing quality''


====Measurement monitor settings====
In this window, the test runs and plane are positioned as follow :
 
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|align = "center"|
[[Image:Balancing_24.png|framed|none]]
<br>''Display settings - Diagram 1 - Plane 1''
|align = "center"|
[[Image:Balancing_25.png|framed|none]]
<br>''Display settings - Diagram 2 - Plane 2''
 
|}
 
'''Notice: The balancing module''' always starts with the monitor that has been used last.
 
All Settings can be modified:
 
* Set the number of graphs, the type and the order in which you want to see them.
Graphs with frames can be treated like windows in Windows®.


* Chose the scaling of the axis or use auto scaling (Y-axis only).
[[Image:Bal_2_Test_Prep.png|framed|none]]<br>
* Colors and graph names can be arranged.
* <u>Click "Set" to create your new monitor.</u>
* Use "Save" at the bottom to save your new monitor.
If you want to use several monitors with different layouts put existing monitors into the monitor table (double click a field in the table).
 
You can save and reload this selection of layouts.


Continue with "Close"
You can export and reload a configuration with the "Export" and "Load" buttons.


==One plane balancing==
==One plane balancing==
Line 468: Line 336:
If you use accelerometers for your measurement the signal can be integrated to show vibration velocity.
If you use accelerometers for your measurement the signal can be integrated to show vibration velocity.


'''The analyzer is now ready for measurement.'''
The '''Rotor''' window is automatically displayed. You can now prepare your test run or close this window to set it up later:
 
Your settings are shown by a red point in the polar graph.
 
There are three methods:
 
* '''Remove test masses ''' : The test mass will be removed after test for example bolts etc.
* '''Keep test masses ''' : The test mass cannot be removed after the test (for example for welding or drilling etc…)
* '''Displace two masses per plane '''for machines with slidable balancing weights.
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).
 
The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''</font>.
 
[[Image:Bal_1_Test_Prep.png|framed|none]]
 
Click on OK to come back on the measurment window.<br>
 
'''The analyzer is now ready for measurement.'''<br>


To start the analyzer click <font color="#FF0000">'''(1)''' </font>or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed.
To start the analyzer click '''(1)''' or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed.


To open and changing any settings click
To open and changing any settings click


<font color="#FF0000">'''(a)''' </font>Analyzer setup
'''(a)''' Analyzer setup


'''(b)''' Rotor geometry and balancing quality
'''(b)''' Rotor geometry and balancing quality
Line 482: Line 367:
'''(d)''' Balancing calculation
'''(d)''' Balancing calculation


[[Image:Balancing_26.png|framed|none]]
[[Image:Bal_Wind.png|framed|none]]


* ''Measurement display - start analyzer''
* ''Measurement display - start analyzer''
====Measurement monitor settings====
[[Image:Bal_MonitorSetting.png|framed|none]]
<br>''Display settings - Diagram 2 - Plane 2''
'''Notice: The balancing module''' always starts with the monitor that has been used last.
All Settings can be modified:
* Set the number of graphs, the type and the order in which you want to see them.
Graphs with frames can be treated like windows in Windows®.
* Chose the scaling of the axis or use auto scaling (Y-axis only).
* Colors and graph names can be arranged.
* <u>Click "Set" to create your new monitor.</u>
* Use "Save" at the bottom to save your new monitor.
If you want to use several monitors with different layouts put existing monitors into the monitor table (double click a field in the table).
You can save and reload this selection of layouts.
Continue with "Close"


===Initial run===
===Initial run===
Click "Initial run"
Click "Initial run"


Click "Average" <font color="#FF0000">'''(2)'''</font>, when rotor is at stable speed (Stationary state).
Click "Average" '''(2)''', when rotor is at stable speed (Stationary state).


The figure below shows the result of the initial run.
The figure below shows the result of the initial run.


[[Image:Balancing_27.png|framed|none]]
[[Image:Bal_1_Init.png|framed|none]]


''Initial run - start average''
''Initial run - start average''
Line 499: Line 406:
Explanation of the graphs:
Explanation of the graphs:


Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" <font color="#FF0000">'''(1)''' </font>and save the initial measurement <font color="#FF0000">'''(2)'''</font>.
Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" '''(1)''' </font>and save the initial measurement '''(2)'''</font>.


[[Image:Balancing_28.png|framed|none]]
[[Image:Bal_1_Stopped.png|framed|none]]


''Initial run''
''Initial run''
Line 507: Line 414:
After saving the initial run the results are displayed as shown in '''the figure below.'''
After saving the initial run the results are displayed as shown in '''the figure below.'''


[[Image:Balancing_29.png|framed|none]]
[[Image:Bal_1_Init_Result.png|framed|none]]


''Results of Initial run''
''Results of Initial run''
Line 513: Line 420:
On this figure, the blue circle, representing the allowed residual unbalance, shows directly after the initial run if the machine meets the required balancing quality or not.
On this figure, the blue circle, representing the allowed residual unbalance, shows directly after the initial run if the machine meets the required balancing quality or not.


'''Notice: '''At this point the tables only show amplitude and phase. The unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki> or in <nowiki>[</nowiki>oz in<nowiki>]</nowiki> can only be calculated after the rotor sensitivity is measured in the test run. Click OK to proceed to the test run.
'''Note: '''At this point the tables only show amplitude and phase. The unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki> or in <nowiki>[</nowiki>oz in<nowiki>]</nowiki> can only be calculated after the rotor sensitivity is measured in the test run. Click OK to proceed to the test run.


===Test run===
===Test run===
Line 519: Line 426:


* Fix a test mass to the rotor.
* Fix a test mass to the rotor.
* Mass, value and position must be set in the rotor geometry table.
* Mass, value and position must be as set in the rotor geometry table.<br>
To do this, click "Rotor" in the Measurement monitor to open the rotor geometry window'''.'''


Your settings are shown by a red point in the polar graph.
To see the position and mass, click "Rotor" in the Measurement monitor to open the rotor geometry window'''.'''
[[Image:Bal_1_Test_Prep.png|framed|none]]<br>


There are three methods:
Your settings are shown by a red point in the polar graph. If you haven't set the test mass previously, you can do it now.


* '''Remove test masses '''after test for example bolts etc.
Click on OK to go back in the Measurement window. Click "Test run" '''(1)''' </font>and save the measurement '''(2)'''</font>.
* '''Keep test masses '''after the test (for example for welding or drilling etc…)
* '''Displace two masses per plane '''for machines with slidable balancing weights.
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).
 
The settings are saved automatically when closing the window. To use these settings in another project, click on export <font color="#FF0000">'''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project <font color="#FF0000">'''(2)'''</font>.
 
[[Image:Balancing_30.png|framed|none]]
 
''Test mass positioning for one plane''
 
Click "Test run" <font color="#FF0000">'''(1)''' </font>and save the measurement <font color="#FF0000">'''(2)'''</font>.


After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.


[[Image:Balancing_31.png|framed|none]]
[[Image:Bal_1_TestRun_Save.png|framed|none]]


''Test run''
''Test run''
Line 552: Line 448:
The amplitude scaling of the polar graph is now displayed in unbalance unit <nowiki>[</nowiki>g mm<nowiki>]</nowiki> (blue axis).
The amplitude scaling of the polar graph is now displayed in unbalance unit <nowiki>[</nowiki>g mm<nowiki>]</nowiki> (blue axis).


The blue circle now represents the allowed residual unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki>.
The blue circle now represents the allowed residual unbalance in <nowiki>[</nowiki>g mm<nowiki>]</nowiki> according to the specified class (ISO1940/1).


The result table now shows the results for initial run and test run.
The result table now shows the results for initial run and test run.
Line 560: Line 456:
<u>Example</u>
<u>Example</u>


<font color="#FF0000">'''(1)''' </font>Click to save the test run result
'''(1)''' Click to start the calculation
 
'''(2)''' Click to start the calculation


[[Image:Balancing_32.png|framed|none]]
[[Image:Bal_1_test_Result.png|framed|none]]


''Test run results''
''Test run results''
Line 575: Line 469:


'''Orange point '''unbalance with test weight
'''Orange point '''unbalance with test weight
Proceed to the balancing prognosis to study the effect of available balancing weights.


----
----
Line 583: Line 475:


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|<font color="#FF0000">'''(1)''' </font>Select Init run <nowiki>+</nowiki> Test run<br>'''(2)''' Click OK to start the calculation<br>'''(3)''' Result - Unbalance and Phase  
|'''(1)''' </font>Select Init run <nowiki>+</nowiki> Test run<br>'''(2)''' Click OK to start the calculation<br>'''(3)''' Result - Unbalance and Phase  
|'''(4)''' Result - proposal mass and position<br>'''(5)''' Proposal position  
|'''(4)''' Result - proposal mass and position : You need to enter the real mass you will add/remove<br>'''(5)''' Proposal position  


|}
|}


[[Image:Balancing_33.png|framed|none]]
[[Image:Bal_1_imb_calc.png|framed|none]]


''Calculation of balancing weights''
''Calculation of balancing weights''
If the prognostic is in the blue circle, the imbalanced of the rotor will be within the class after the mass correction.


====Balancing prognosis====
====Balancing prognosis====
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.


Set mass and position of the mass you want to use in column "Mounted Mass".
Set mass and position of the mass you want to use in column "Mounted Mass". The software automatically calculates the expected residual unbalance (green point in polar graph).


Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).
In this example, we only had a mass of 5 grams available instead of the calculated 4.685g mass to add at the 7th position. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.
 
Only a mass of 4.2 gram was available and set to position 7. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.


{|border="2" cellspacing="0" cellpadding="4" width="100%"
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|<u>Example</u><br><font color="#FF0000">'''(1)''' </font>Proposal mass and position<br>'''(2)''' Click to enter the mass 4,2 gram<br>'''(3)''' Initial Unbalance  
|<u>Example</u><br>'''(1)''' </font>Proposal mass and position<br>'''(2)''' Click to enter the mass 4,2 gram<br>'''(3)''' Initial Unbalance  
[[Image:Balancing_34.png|framed|none]]
[[Image:Balancing_34.png|framed|none]]
<br>'''(4)''' Prognosis Unbalance  
<br>'''(4)''' Prognosis Unbalance  
Line 611: Line 503:
<br>Prognosis<br>
<br>Prognosis<br>


|-
|}
|
====Balancing Run====
* Click "balancing run" (bottom left)
 
* Click "Start" start or F2. The measurement is displayed.
Once you have mounted the test mass as indicated by the software, you can perform a Balancing run, to ensure the rotor is now properly balanced.
* Click "Average", when rotor is at stable speed (Stationary state)
 
|align = "center"|
To do so, Go back in the measurement window and press start.
[[Image:Balancing_37.png|framed|none]]
 
<br>''Balancing run (Black point: Initial run, Orange point: Test run, Dark green point: Balancing run)''
*'''(1)''' Click on average
*'''(2)''' Select "Balancing Run1"
*'''(3)''' Save the measurement


|}
[[Image:Bal_1_BalRun.png|framed|none]]


These points only appear if they are marked "active" in the result window. Then, save the balancing result. At any stage saved results can be reloaded using the "Load Measurement" buttons. They also can be overwritten.
The orange and green point represent the initial and resulting imbalance. These points only appear if they are marked "active" in the result window. Then, save the balancing result. At any stage saved results can be reloaded using the "Load Measurement" buttons. They also can be overwritten.


<u>Example</u>
<u>Example</u>


<font color="#FF0000">'''(1)''' </font>Click to save the balancing run result
'''(1)''' </font>Click to save the balancing run result


'''(2)''' Click to start the calculation
'''(2)''' Click to start the calculation


[[Image:Balancing_38.png|framed|none]]
[[Image:Bal_1_BalRun_Resut.png|framed|none]]


''Balancing run results''
''Balancing run results''
Line 636: Line 530:
====Balancing report====
====Balancing report====


[[Image:Balancing_39.png|framed|none]]
[[Image:Bal_1_Overview.png|framed|none]]


''Balancing results overview''
''Balancing results overview''<br>


The overview in the following figure now shows the chronological mass predictions and settings as well as the final result ("End").
The overview in the following figure now shows the chronological mass predictions and settings as well as the final result ("End").
Line 646: Line 540:
This overview can be exported into a Microsoft® Editor file (*.txt)''' '''by clicking "Report".
This overview can be exported into a Microsoft® Editor file (*.txt)''' '''by clicking "Report".


[[Image:Balancing_40.png|framed|none]]
[[Image:Bal_1_Report.png|framed|none]]


''Balancing Report''
''Balancing Report''
Line 655: Line 549:


===Measurements, display, storage===
===Measurements, display, storage===
<font color="#FF0000">'''(1)''' </font>Click "Start" start or F2. Measurement is displayed.
After setting up the acquisition channel and the machine type, you may setup the test run in the "Rotor" window. For two plane balancing, you will need to perform two test run, and set a mass on each plane. By example, here, we are putting a 5g mass at pos. 3 on the first plane for the test run1 and 5g mass at pos. 8 on the second plane for the test run2. We are not putting mass on the second plane for test run1 and no mass on the first plane for test run2 :
 
[[Image:Bal_2_TestPrep_real.png|framed|none]]<br>


[[Image:Balancing_41.png|framed|none]]
*'''Note :''' You may '''not''' mount the masses at this stage. <br>
 
Then Press '''Ok''' to reach the measurement window. '''The analyser in now ready for measurement.'''
 
'''(1)''' </font>Click "Start" start or F2. Measurement is displayed.
 
[[Image:Bal_2_Init.png|framed|none]]


''Measurement Display''
''Measurement Display''


<font color="#FF0000">'''(1)''' </font>Click "Average" when rotor is at stable speed (Stationary state).
'''(1)''' </font>Click "Average" when rotor is at stable speed (Stationary state).


[[Image:Balancing_42.png|framed|none]]
[[Image:Bal_2_Init2.png|framed|none]]


''Measurement Display''
''Measurement Display''
Line 670: Line 572:
The figure shows the result of the initial run.
The figure shows the result of the initial run.


<font color="#FF0000">'''(1)''' </font>Click "Initial run"
'''(1)''' </font>Click "Initial run"


'''(2)''' Save your initial measurement
'''(2)''' Save your initial measurement


[[Image:Balancing_43.png|framed|none]]
[[Image:Bal_2_Init3.png|framed|none]]


''Initial run''
''Initial run''


[[Image:Balancing_44.png|framed|none]]
[[Image:Bal_2_Init_Result.png|framed|none]]


''Results of Initial run''
''Results of Initial run''


===Test run 1 and 2===
===Test run 1===
<u>Preparation</u>
<u>Preparation</u>


* Fix a test mass to the rotor.
* Fix a test mass to the rotor.
* Mass, value and position must be set in the rotor geometry table.
* Mass, value and position must be set in the rotor geometry table.
To do this click "Rotor" in the Measurement monitor <font color="#FF0000">'''(b)''' </font>to open the rotor geometry window'''.'''
To do this click "Rotor" in the Measurement monitor '''(b)''' </font>to open the rotor geometry window'''.'''


Your settings are shown by a red point in the polar graph.
Your settings are shown by a red point in the polar graph.
Line 696: Line 598:
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
It shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 3 (<font color="#FF0000">'''2)''' </font>(75°; radius 100 mm) <font color="#FF0000">'''(1)'''</font>
It shows an example where test mass is to be removed. The test mass of 5 grams is set at position 3 '''(1)''' </font>(75°; radius 100 mm) '''(2)''' </font>


The settings are saved automatically when closing the window.
The settings are saved automatically when closing the window.


[[Image:Balancing_45.png|framed|none]]
[[Image:Bal_2_Test_PrepRun1.png|framed|none]]


''Test mass positioning for two planes - Test run 1 - Test mass 1 - Plane 1''
''Test mass positioning for two planes - Test run 1 - Test mass 1 - Plane 1''


[[Image:Balancing_46.png|framed|none]]
[[Image:Bal_2_TestRun1.png|framed|none]]


''Test run 1''
''Test run 1''


Click "Test run" <font color="#FF0000">'''(1)''' </font>and save the measurement <font color="#FF0000">'''(2)'''</font>.
Click "Test run" '''(1)''' </font>and save the measurement '''(2)'''</font>.


After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.


[[Image:Balancing_47.png|framed|none]]
[[Image:Bal_2_TestRun1Fin.png|framed|none]]


''Remove Test mass 1''
''Remove Test mass 1''


[[Image:Balancing_48.png|framed|none]]
[[Image:Bal_2_TestRun1_Result.png|framed|none]]


''Test run 1 results''
''Test run 1 results''


===Test run 2===
<u>Preparation</u>
<u>Preparation</u>


Line 733: Line 636:
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Keep test masses '''after test for example welding or drilling etc.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
* '''Displace two masses per plane '''for machines with slidable balancing weights.
'''A'''n example is shown where test mass is to be removed. The test mass of 4.2 grams <font color="#FF0000">'''(3)''' </font>is set at position 4 (105°; radius 100 mm) <font color="#FF0000">'''(4)'''</font>
An example is shown where test mass is to be removed. The test mass of 5 grams '''(4)''' </font>is set at position 8 (225°; radius 100 mm) '''(3)'''</font>


The settings are saved automatically when closing the window.
The settings are saved automatically when closing the window.


[[Image:Balancing_49.png|framed|none]]
[[Image:Bal_2_Rotor_2.png|framed|none]]


''Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2''
''Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2''<br>


Set the Run number to 2 <font color="#FF0000">(1) </font>and save the measurement <font color="#FF0000">(2).</font>
You can now perform the measurement of the second test run as previously ( click '''Start/F2''' and '''Average'''). Then, to save the measurement, set the Run number to 2 (1) </font>and save the measurement (2).</font>


[[Image:Balancing_50.png|framed|none]]
[[Image:Bal_2_testRun2_1.png|framed|none]]


''Test run 2''
''Test run 2''


[[Image:Balancing_51.png|framed|none]]
[[Image:Bal_2_TestRun2_Fin.png|framed|none]]


''Remove Test mass 2''
''Remove Test mass 2''
Line 753: Line 656:
<u>Example</u>
<u>Example</u>


<font color="#FF0000">'''(1)'''  </font>Results for Plane 1 and Plane 2
'''(1)'''  </font>Results for Plane 1 and Plane 2


'''(2)''' Save the results
'''(2)'''   Click to start the calculation


'''(3)'''  Click to start the calculation
[[Image:Bal_2_TestRun2_Result2.png|framed|none]]
 
[[Image:Balancing_52.png|framed|none]]


''Test run 2 - Result, Save and Start Calculate''
''Test run 2 - Result, Save and Start Calculate''
Line 768: Line 669:
<u>Example</u>
<u>Example</u>


<font color="#FF0000">'''(1)''' </font>Select Init run <nowiki>+</nowiki> Test run
'''(1)''' </font>Select Init run <nowiki>+</nowiki> Test run


'''(2)''' Click OK to start the calculation
'''(2)''' Click OK to start the calculation


[[Image:Balancing_53.png|framed|none]]
[[Image:Bal_2_imbal_Calc.png|framed|none]]


''Test run 2''
''Test run 2''
Line 788: Line 689:
<u>Example</u>
<u>Example</u>


<font color="#FF0000">'''(1)''' </font>Result - Unbalance 1 and Phase 1
'''(1)''' </font>Result - Unbalance 1 and Phase 1


'''(2)''' Result - Unbalance 2 and Phase 2
'''(2)''' Result - Unbalance 2 and Phase 2
Line 800: Line 701:
'''(6)'''  Proposal mass and position Plane 2
'''(6)'''  Proposal mass and position Plane 2


[[Image:Balancing_54.png|framed|none]]
[[Image:Bal_2_imbal_Calc_2.png|framed|none]]


''Test run results''
''Test run results''
Line 807: Line 708:
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.


Set mass and position of the mass you want to use in column "Mounted Mass" <font color="#FF0000">(1), (2)</font>
Set mass and position of the mass you want to use in column "Mounted Mass" (1), (2)</font>


Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).
Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).


Only a mass of 4.2 grams was available, and set to position 7. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.
Masses of 1 and 3.5 grams were available, and set to positions 5 and 6 on the first plane, and calculated masses are too small for the second plane. Therefore, we don't mount masses on the second plane as it is already balanced. <br>


[[Image:Balancing_55.png|framed|none]]
The prognosis shows that the residual unbalance (light green point in polar graph) moves inside the blue circle.
 
[[Image:Bal_2_MountedMass.png|framed|none]]


''Prognosis''
''Prognosis''
Line 819: Line 722:
<u>Execution:</u>
<u>Execution:</u>


* Click "balancing run" (bottom left)
* Click "Online balancing" (bottom left)
*  Click "Start" start or F2.  Measurement is displayed.
*  Click "Start" start or F2.  Measurement is displayed.
* Click  "Average", when rotor is at stable speed .(Stationary state)
* Click  "Average", when rotor is at stable speed .(Stationary state)
Line 838: Line 741:
(These points only appear if they are marked "active" in the result window)
(These points only appear if they are marked "active" in the result window)


Save the balancing result.
To save the balancing result, go back in the standard window by clicking on '''"Standard"''' and save as usual.


At any stage saved results can be reloaded using the "Load Measurement" buttons.
[[Image:Bal_2_onlineBal.png|framed|none]]
 
[[Image:Balancing_56.png|framed|none]]


''Balancing run''
''Balancing run''
Line 853: Line 754:
* Click "Report" in''' '''to''' '''export this table into a Microsoft® Editor file (*.txt).
* Click "Report" in''' '''to''' '''export this table into a Microsoft® Editor file (*.txt).


[[Image:Balancing_57.png|framed|none]]
[[Image:Bal_2_FinalResult.png|framed|none]]


''Balancing run results''
''Balancing run results''
Line 861: Line 762:
====Balancing report====
====Balancing report====


[[Image:Balancing_58.png|framed|none]]
[[Image:Bal_2_Overview.png|framed|none]]


''Balancing results overview''
''Balancing results overview''
Line 873: Line 774:
This overview can be exported into a Microsoft® Editor file (*.txt) as a Balancing Report.
This overview can be exported into a Microsoft® Editor file (*.txt) as a Balancing Report.


[[Image:Balancing_59.png|framed|none]]
[[Image:Bal_2_Report.png|framed|none]]


''Balancing Report''
''Balancing Report''


[[Image:Balancing_60.png|framed|none]]
[[Image:Bal_2_Before_After.png|framed|none]]
 
''Unbalance before
[[Image:Balancing_61.png|framed|none]]
and after
[[Image:Balancing_62.png|framed|none]]
balancing''


[[Image:Balancing_63.png|framed|none]]
''Unbalance before  [[Image:Balancing_61.png]] and after [[Image:Balancing_62.png]]balancing''


''Vibration measurement before
[[Image:Bal_2_Before_After_2.png|framed|none]]
[[Image:Balancing_64.png|framed|none]]
and after
[[Image:Balancing_65.png|framed|none]]
balancing''


[[category:Balancing]]
''Vibration measurement before [[Image:Balancing_64.png]]and after [[Image:Balancing_65.png]]balancing''

Latest revision as of 14:48, 26 June 2020

Single / Dual PLANE Balancing: User's Manual

Introduction

A rotor is a shaft rotating around its axis during service. In general, such a rotor consists of a shaft with one or more discs fitted to the axle. Such discs can be fly wheels, grinding wheels, turbine wheels, etc. The shaft is usually running in bearings allowing the rotation of the body. Depending on their rotational speed, two basic categories can be defined to classify rotors: rotors with rigid shaft, and rotors with flexible shaft.

If the operating speed remains below half of the first critical bending speed, the shaft does not deflect : it may be considered as a rotor with a rigid shaft. At such operational speeds and due to the non circular cross section of the rotor, the axis of rotation (Z) and the inertial axis (Δ) does not coincide (e.g. the mass is not evenly dispatched in a section of the shaft). This may results in a tumbling movement of the structure, this amplitude depends on the bearing clearance and stiffness. In any case, the bearings are subjected to unnecessary or even not allowed loads.

Unbalance : Inertial axis does not coincide with rotational axis.
The unevenly mass distribution is represented by "m"


At higher speeds the shaft will deflect, due to is own stiffness. In that case, it might be considered as a rotor with flexible shaft. Depending on the position of the discs on the shaft they can even be inclined and thus create an oil whirl. In that case, the Multiplane Balancing solution must be used.

An increase of the running quality is achieved through reduction of the asymmetry by means of local addition or reduction of mass. Thus the inertial axis is moved to approach the rotational axis. Rigid rotors can be sufficiently balanced in one or two planes. In practice depending of the number of transducers used and the number of planes four cases can be considered.


Case
Number
Balancing planes Vibration Transducers Tach sensors
1 1 1 1
2 2 2 1
3 1 2 1
4 2 4 1


Case 1 The simplest case is to use one vibration transducer fitted for example to the rotor housing near one bearing in radial direction.
Case 2 For two planes fit one transducer near each bearing in radial direction, as above.
Case 3 To take into account the different stiffness of bearings in horizontal and vertical direction, two transducers can be used. The resultant of these two measurements is calculated and then used for balancing. To do this, transducer 1 has to be mounted radial in 45° to the horizontal, and transducer 2 in 135°.
Case 4 The same applies for two planes with 4 transducers.

Angular adjustments

To identify the angular position of the balancing masses, the tach point and the accelerometer direction must be taken into account.

Balancing 06.png

Angular adjustments

Tach point

The tach trigger point should have the same angular position as position 1. If this is not possible, the angular difference can be corrected in the rotor geometry setup as "Offset".

Accelerometer

The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example, in Sketch 1, the angular correction is 90° and the offset is -15 °.

Tip

If the angular position of the tach signal is unknown, place a test mass to whatever position and define it as position 1 (0°) in the rotor geometry table. Now all angles are relative, referred to the position of the respective test mass position.

Basic balancing procedure

The execution of this balancing task can easily be achieved with your OROS 3-SERIES Analyzer (and its NVGate software running in the background) and the Balancing module. This module can be used for balancing in the lab, as well as on site. The steps in the balancing procedure are shown in the following Figures, with the corresponding explanations.

Balancing procedure

1 Initial Setting:

- Load or create a project

- Choose number of planes and Transducers (Case 1 – 4)

- Setup OROS 3-SERIES analyzer

- Introduce the rotor data

- Setup Monitor

2 Initial run

- Choose and fix a test weight

3 Test runs 1 or 2

- Calculation of the balancing weights

- Balancing prognosis

4 Balancing run

- Report

- Physical

Physical Background

The initial run analyzes the behavior of the rotor due to its initial unbalance.

During the test run, the applied test masses modify the position of the unbalance. This yields the sensitivity of the rotor. Thus with the knowledge of the reaction of the rotor to added masses, suitable masses can be calculated to compensate the initial unbalance.

For balancing in one plane, just one test mass and one test run is necessary. It is important that the angular position of the initial unbalance is changed significantly by the test mass. Take this into account when choosing test weight and position.

When balancing in two planes, two test runs are necessary. For each run only one test mass is necessary to be positioned in one of both planes respectively. Again, in both test runs the position of the unbalance must be changed by the test masses.

Assumptions

We assume a linear system. This means the rotor has to run at one stable speed during all measurement runs. The system has to be in a stationary state. If any alterations of the vibration behavior occur during the balancing procedure no meaningful balancing calculations can be obtained. Only the test weight should modify the unbalance of the rotor, but the rest of the system has to stay unchanged.

Example

Imagine a rotating machine to be balanced when standing untightened on the floor. After the test mass is mounted the increased unbalance causes the machine to move. Holding or fixing the machine during the test run will cause wrong balancing results. To overcome this you must choose a lower test mass or position to reduce the unbalance. If this doesn't work you could fix the machine during the complete balancing procedure. After this basic balancing, execute a second complete balancing procedure with the machine unfixed (in normal operating conditions).

General advice

If the test weight does not sufficiently modify the angular position of the unbalance, the rotor sensitivity can not be determined precisely, and balancing calculation is not meaningful. If the program detects this case, it will give a corresponding error message.

If no improvement is achieved during a complete balancing run, the angular position of the initial unbalance and the unbalance obtained after positioning of the test mass should be checked. If the difference is less than 10° the test run must be repeated with a different position of the test mass.

Notice: Before repeating the test run with weights in new positions, the balancing weights should be removed. After the test run balancing weights should be calculated again. Now the balancing run can be repeated.

Getting started

To start the application, click on the Balancing-Solution-Icon.

Balancing 07.png

Balancing Solution

The OROS Single / Dual Balancing module appears with the following start screen

Bal start.png

Start Balancing Solution of rigid rotors

- "Online" to start measurements, lunching NVGate.

- "Offline" to run the software offline.

- "Setup" to enter in the parameters of Balancing (selection of the language and location of NVGate.exe).

- "Standard" mode : Full access to the software

- "Restricted" mode : Restricted access (do not allow to create a new project)

When starting online the system automatically start NVGate, while displaying the dialog window below.

Connect Analyser.png

NVGate start request

Then, select the running mode.

Connection.png

Select the NVGate mode

  • To proceed to a measurement, start NVGate in "Connected mode"
  • For Offline access the "Office mode" can also be used.
  • When the software starts, the NVGate software is displayed. Minimize NVGate.
  • NVGate - Start'n Go

It is recommended to start with a default project. It is recommended to set your special user name to "Restricted user" to prevent any further changes of your settings. Then, the NVGate window can be minimized.

Settings

Settings follow the same steps whether it is for one plane balancing (single) or two planes balancing (dual). Thus, description below is given for the balancing of a two planes rotor.

Project management

Project Manager window
(1) Project Base : List of the project in the current Project Base
(2) Projects Base Path :Change the Project Base
(3) Project Browse : Add project in the current Base.
(4) New Project : Create a new project
(5) Exit : Exit the balancing program
Bal Proj Manager.png
Load an existing Project

To load an existing project, select the project in the (1) Project Base and click OK.

You can import a project form another database by clicking on (3) Browse Project.

Create a new Project

To create a new project, click on (4) New Project and enter the name of the project in the appearing ribbon at the bottom of the window :

New Proj.png


The new project will then appear in the Project Base, select it and click OK :

New Proj2.png


Select the configuration of the machine

This window, called "Analyser", will help you to quickly setting up your measurement.

First, select the configuration of your machine according to the number of planes, the geometry of the rotor (pos. of planes and bearings) and the number of vibration sensors.

Balancing Planes Setup – 2 Planes and 2 Sensors


Here, we are selecting a two planes rotor, with both planes between the bearings and 2 sensors.

Connect your transducers to the corresponding inputs on your 3-SERIES analyzer. The Balancing program will automatically associates the physical inputs of the frontend with the channels for the balancing according to the drawing : In1 is the channel 1 of the frontend, In2 is the channel 2, In3 the channel 3 and In4 the channel 4.

Dynamical Channels settings

Once you have selected the correct type of machine and connected the sensors to the frontend, you may go in the "Input" Tab to set your channels.

Bal Dyn Chann.png

Adjustment of channels

Set the input range and the coupling for your transducer, as well as his unit and sensitivity and physical quantity. You may also set the Sampling rate according to the maximal Rotating speed of the shaft (The sampling rate must be higher than the double of the max RPM*60).

To choose your transducer from the transducer data base, click on Transducer.

Transducer database

Balancing 22.png

Transducer data base

For easier and faster adjustment use the transducer data base.

Input your transducer in the list shown by clicking the corresponding fields and adjust an input transducer label, unit and sensitivity.

To select a transducer click in the corresponding line, and choose the analyzer channel, where this transducer is connected to. Click Set.

The transducer data base can be saved and reloaded.

It is also possible to create several data bases for example for different users and their transducers.

Setting the tachometer

To set the tachometer, you need to go into the "Speed" tab :

Bal Tacho.png

Note: Your tach signal must have one pulse per revolution. If you have more than one pulse, you can set the maximal speed as Real_speed*Pulse/rev.

  • Set the range, coupling and slope for this tach signal.
  • Input the balancing speed.
  • Set the number of averages for your measurements.

Set a phase adjustment

To set a phase adjustment, you can specify the position of the sensors. To enter the menu, click on "Position":

Bal Position.png


The position of each sensors and the tachometer can be set :

Bal Position Menu.png


Note : The 0° position is the position of the tachometer reflector on the shaft. The angle are counted positive in the anti-rotation direction.

Saving the channel and measuring setup

All setup settings can be saved and reloaded with "Save" and "Load" buttons.

Note: The balancing module always starts with the last analyzer settings used.

You do not need to do all adjustments for a new project. Just load the setup of an existing project.

Tip:

If you want to make sure you always start with the same settings, create a reference project with all settings adjusted properly. Each part of the project is saved with a specific extension.

  • Reference Project = *.WSR
  • Analyzer settings = *.STP
  • Monitor = *.DGW
  • Rotor geometry = *.ROT (created when saving *.STP)

In the file menu, "File / Save Project" can be used to save the project.

For a new Project with these Settings: Load Reference Project.

This is now the last project that has been used:

  • Create New Project: It has the settings of the Reference Project.
  • Click "Transducer" to open the data base.

Or

  • Click "Continue" to proceed to the next step.



Rotor geometry and balancing quality

(1) No. of mass positions both planes
(2) Radius for both planes[mm]
(3) Offset of the first mass position regarding the reference at 0° [Deg]
(4) Click on Apply to display the circle
(5) Unit of Unbalance [g mm], [oz in] or [g in]
(6) Rotor mass
(7) Speed RPM
(8) Quality class (def. in ISO1940/1)
(9) Maximal residual unbalance (according to ISO1940) [g mm]
(10) Residual unbalance [oz in]
Bal Rotor Quality.png

Rotor geometry and balancing quality

In this window, the test runs and plane are positioned as follow :

Bal 2 Test Prep.png


You can export and reload a configuration with the "Export" and "Load" buttons.

One plane balancing

Measurements, display, storage

Execute the following balancing procedure:

  • Initial run
  • Test run
  • Calculation of balancing weights
  • Balancing run

All runs can be saved, reloaded and overwritten.

If you use accelerometers for your measurement the signal can be integrated to show vibration velocity.

The Rotor window is automatically displayed. You can now prepare your test run or close this window to set it up later:

Your settings are shown by a red point in the polar graph.

There are three methods:

  • Remove test masses  : The test mass will be removed after test for example bolts etc.
  • Keep test masses  : The test mass cannot be removed after the test (for example for welding or drilling etc…)
  • Displace two masses per plane for machines with slidable balancing weights.

The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).

The settings are saved automatically when closing the window. To use these settings in another project, click on export (1) and save it in the sub directory of the other project. Proper settings can be loaded from another project (2).

Bal 1 Test Prep.png

Click on OK to come back on the measurment window.

The analyzer is now ready for measurement.

To start the analyzer click (1) or [F2] and the Measurement is displayed.

To open and changing any settings click

(a) Analyzer setup

(b) Rotor geometry and balancing quality

(c) Display setup

(d) Balancing calculation

Bal Wind.png
  • Measurement display - start analyzer

Measurement monitor settings

Bal MonitorSetting.png


Display settings - Diagram 2 - Plane 2

Notice: The balancing module always starts with the monitor that has been used last.

All Settings can be modified:

  • Set the number of graphs, the type and the order in which you want to see them.

Graphs with frames can be treated like windows in Windows®.

  • Chose the scaling of the axis or use auto scaling (Y-axis only).
  • Colors and graph names can be arranged.
  • Click "Set" to create your new monitor.
  • Use "Save" at the bottom to save your new monitor.

If you want to use several monitors with different layouts put existing monitors into the monitor table (double click a field in the table).

You can save and reload this selection of layouts.

Continue with "Close"

Initial run

Click "Initial run"

Click "Average" (2), when rotor is at stable speed (Stationary state).

The figure below shows the result of the initial run.

Bal 1 Init.png

Initial run - start average

Explanation of the graphs:

Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" (1) and save the initial measurement (2).

Bal 1 Stopped.png

Initial run

After saving the initial run the results are displayed as shown in the figure below.

Bal 1 Init Result.png

Results of Initial run

On this figure, the blue circle, representing the allowed residual unbalance, shows directly after the initial run if the machine meets the required balancing quality or not.

Note: At this point the tables only show amplitude and phase. The unbalance in [g mm] or in [oz in] can only be calculated after the rotor sensitivity is measured in the test run. Click OK to proceed to the test run.

Test run

Preparation

  • Fix a test mass to the rotor.
  • Mass, value and position must be as set in the rotor geometry table.

To see the position and mass, click "Rotor" in the Measurement monitor to open the rotor geometry window.

Bal 1 Test Prep.png


Your settings are shown by a red point in the polar graph. If you haven't set the test mass previously, you can do it now.

Click on OK to go back in the Measurement window. Click "Test run" (1) and save the measurement (2).

After every test run, don't forget to remove the test mass (3).

Bal 1 TestRun Save.png

Test run


Calculating balancing weights

After saving the test run the result is shown.

The amplitude scaling of the polar graph is now displayed in unbalance unit [g mm] (blue axis).

The blue circle now represents the allowed residual unbalance in [g mm] according to the specified class (ISO1940/1).

The result table now shows the results for initial run and test run.

Proceed to the calculation of the balancing weights now.

Example

(1) Click to start the calculation

Bal 1 test Result.png

Test run results

Click "Calculate" to determine mass and position of the balancing weights.

The weights and positions for zero unbalance appear in the table and are shown by red points.

Blue point initial unbalance

Orange point unbalance with test weight


Example

(1) Select Init run + Test run
(2) Click OK to start the calculation
(3) Result - Unbalance and Phase
(4) Result - proposal mass and position : You need to enter the real mass you will add/remove
(5) Proposal position
Bal 1 imb calc.png

Calculation of balancing weights

If the prognostic is in the blue circle, the imbalanced of the rotor will be within the class after the mass correction.

Balancing prognosis

The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.

Set mass and position of the mass you want to use in column "Mounted Mass". The software automatically calculates the expected residual unbalance (green point in polar graph).

In this example, we only had a mass of 5 grams available instead of the calculated 4.685g mass to add at the 7th position. The prognosis shows that the residual unbalance (blue point in polar graph) moves to the green point inside the blue circle.

Example
(1) Proposal mass and position
(2) Click to enter the mass 4,2 gram
(3) Initial Unbalance
Balancing 34.png


(4) Prognosis Unbalance

Balancing 35.png

(inside of the blue circle)

Balancing 36.gif


Prognosis

Balancing Run

Once you have mounted the test mass as indicated by the software, you can perform a Balancing run, to ensure the rotor is now properly balanced.

To do so, Go back in the measurement window and press start.

  • (1) Click on average
  • (2) Select "Balancing Run1"
  • (3) Save the measurement
Bal 1 BalRun.png

The orange and green point represent the initial and resulting imbalance. These points only appear if they are marked "active" in the result window. Then, save the balancing result. At any stage saved results can be reloaded using the "Load Measurement" buttons. They also can be overwritten.

Example

(1) Click to save the balancing run result

(2) Click to start the calculation

Bal 1 BalRun Resut.png

Balancing run results

Balancing report

Bal 1 Overview.png

Balancing results overview

The overview in the following figure now shows the chronological mass predictions and settings as well as the final result ("End").

Also the prehistory (masses present at start of actual balancing) can be seen in column "Start".

This overview can be exported into a Microsoft® Editor file (*.txt) by clicking "Report".

Bal 1 Report.png

Balancing Report

Scroll if anything is not visible on the screen.

Two planes balancing

Measurements, display, storage

After setting up the acquisition channel and the machine type, you may setup the test run in the "Rotor" window. For two plane balancing, you will need to perform two test run, and set a mass on each plane. By example, here, we are putting a 5g mass at pos. 3 on the first plane for the test run1 and 5g mass at pos. 8 on the second plane for the test run2. We are not putting mass on the second plane for test run1 and no mass on the first plane for test run2 :

Bal 2 TestPrep real.png


  • Note : You may not mount the masses at this stage.

Then Press Ok to reach the measurement window. The analyser in now ready for measurement.

(1) Click "Start" start or F2. Measurement is displayed.

Bal 2 Init.png

Measurement Display

(1) Click "Average" when rotor is at stable speed (Stationary state).

Bal 2 Init2.png

Measurement Display

Initial run

The figure shows the result of the initial run.

(1) Click "Initial run"

(2) Save your initial measurement

Bal 2 Init3.png

Initial run

Bal 2 Init Result.png

Results of Initial run

Test run 1

Preparation

  • Fix a test mass to the rotor.
  • Mass, value and position must be set in the rotor geometry table.

To do this click "Rotor" in the Measurement monitor (b) to open the rotor geometry window.

Your settings are shown by a red point in the polar graph.

There are three methods:

  • Remove test masses after test: for example bolts etc.
  • Keep test masses after test for example welding or drilling etc.
  • Displace two masses per plane for machines with slidable balancing weights.

It shows an example where test mass is to be removed. The test mass of 5 grams is set at position 3 (1) (75°; radius 100 mm) (2)

The settings are saved automatically when closing the window.

Bal 2 Test PrepRun1.png

Test mass positioning for two planes - Test run 1 - Test mass 1 - Plane 1

Bal 2 TestRun1.png

Test run 1

Click "Test run" (1) and save the measurement (2).

After every test run, don't forget to remove the test mass (3).

Bal 2 TestRun1Fin.png

Remove Test mass 1

Bal 2 TestRun1 Result.png

Test run 1 results

Test run 2

Preparation

  • Fix a test mass to the rotor.
  • Mass, value and position must be set in the rotor geometry table.

To do this click "Rotor" in the Measurement monitor to open the rotor geometry window.

Your settings are shown by a red point in the polar graph.

There are three methods:

  • Remove test masses after test for example bolts etc.
  • Keep test masses after test for example welding or drilling etc.
  • Displace two masses per plane for machines with slidable balancing weights.

An example is shown where test mass is to be removed. The test mass of 5 grams (4) is set at position 8 (225°; radius 100 mm) (3)

The settings are saved automatically when closing the window.

Bal 2 Rotor 2.png

Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2

You can now perform the measurement of the second test run as previously ( click Start/F2 and Average). Then, to save the measurement, set the Run number to 2 (1) and save the measurement (2).

Bal 2 testRun2 1.png

Test run 2

Bal 2 TestRun2 Fin.png

Remove Test mass 2

Example

(1) Results for Plane 1 and Plane 2

(2) Click to start the calculation

Bal 2 TestRun2 Result2.png

Test run 2 - Result, Save and Start Calculate


Calculating balancing weights

Example

(1) Select Init run + Test run

(2) Click OK to start the calculation

Bal 2 imbal Calc.png

Test run 2

After saving the test run the result is shown.

The amplitude scaling of the polar graph is now displayed in unbalance unit [g mm] (blue axis).

The blue circle now represents the allowed residual unbalance in [g mm].

The result table now shows the results for initial run and test run.

Proceed to the calculation of the balancing weights now.

Example

(1) Result - Unbalance 1 and Phase 1

(2) Result - Unbalance 2 and Phase 2

(3) Unbalance and Phase Plane 1

(4) Proposal mass and position Plane 1

(5) Unbalance and Phase Plane 2

(6) Proposal mass and position Plane 2

Bal 2 imbal Calc 2.png

Test run results

Balancing prognosis

The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis.

Set mass and position of the mass you want to use in column "Mounted Mass" (1), (2)

Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph).

Masses of 1 and 3.5 grams were available, and set to positions 5 and 6 on the first plane, and calculated masses are too small for the second plane. Therefore, we don't mount masses on the second plane as it is already balanced.

The prognosis shows that the residual unbalance (light green point in polar graph) moves inside the blue circle.

Bal 2 MountedMass.png

Prognosis

Execution:

  • Click "Online balancing" (bottom left)
  • Click "Start" start or F2. Measurement is displayed.
  • Click "Average", when rotor is at stable speed .(Stationary state)

The figure below shows the result of the balancing run.

Explanation of graphs:

Polar graph;

Blue point Initial run

Orange point Test run 1

Olive point Test run 2

Green point Balancing run

(These points only appear if they are marked "active" in the result window)

To save the balancing result, go back in the standard window by clicking on "Standard" and save as usual.

Bal 2 onlineBal.png

Balancing run

To visualize hidden points deactivate the respective covering points. (click the respective field in column "Active" of the tables!)

The dark green point in plane 1 and the orange point in plane 2 were deactivated and the black points are visible again.

  • Click "Overview" to see a summary of the whole balancing job.
  • Click "Report" in to export this table into a Microsoft® Editor file (*.txt).
Bal 2 FinalResult.png

Balancing run results


Balancing report

Bal 2 Overview.png

Balancing results overview

The overview now shows the chronological mass predictions and settings as well as the final result ("End").

Also the prehistory (masses present at start of actual balancing) can be seen in column "Start".

Scroll if anything is not visible on the screen.

This overview can be exported into a Microsoft® Editor file (*.txt) as a Balancing Report.

Bal 2 Report.png

Balancing Report

Bal 2 Before After.png

Unbalance before Balancing 61.png and after Balancing 62.pngbalancing

Bal 2 Before After 2.png

Vibration measurement before Balancing 64.pngand after Balancing 65.pngbalancing