===Ribbons Overview===
[[category:NVGate]]
 
===Interface Overview and Ribbon description===
[[Image:Usersmanual_120.png]]
 
 
More information on the dedicated page :<br>
[[NVGate_Ribbons_overview#Vision_Tab|Vision Tab]]<br>
[[NVGate_Display|Windows: Graph - trace - infotrace]] <br>
[[NVGate Analyzer Setting Browser (ASB)|Analyzer setting browser]] <br>
[[NVGate Control Pannel|Control Pannel]]<br>
[[NVGate Project manager|Project manager]]<br>
[[NVGate Status bar|Status Bar]]<br>
[[NVGate_Software_overview#GoToResult|Go to result]]<br>
 
===Vision Tab===
The Vision interface gathers the analyzers functionalities in simple, clear and easy to identify tabs organized according to the main operations (First steps, measuring, results edition, configuration build-up, automation, general setup etc…).
The Vision interface gathers the analyzers functionalities in simple, clear and easy to identify tabs organized according to the main operations (First steps, measuring, results edition, configuration build-up, automation, general setup etc…).


====Graphic user interface====
Key features have been emphasized by the Vision interface, guiding the users to the best way using their OROS 3-Series analyzer.
=====Tabs & Groups=====
The Vision interface layer features 7 standard tabs. Each tab contains a set of groups which gathers settings, info and buttons about one topic (e.g. disk, FFT or transducers).


<font color="#243F60">
====Operation with Vision====
[[Image:Reports_Tools_Ribbons_202.png|framed|none]]
With Vision the software entries are organized in a logical operations way. There is 7 different tabs corresponding to 3 main operations type:
 
1. <font size = "4">Measure – Setup – Custom</font>


</font>=====Actions:=====
2. <font size = "4">Measurements</font>


The groups contain buttons, setting and check boxes of different types.
The principal goal the instrument is to measure noise and vibrations. The tabs corresponding to such operations are gathered at the top left of the interface: Home & Measurements.


* Buttons:  Left click on it lead to an action or open a dialog box.
3. <font size = "4">Setup and fine tuning</font>
* Examples:
[[Image:Reports_Tools_Ribbons_203.png|framed|none]]
for auto scale or
[[Image:Reports_Tools_Ribbons_204.png|framed|none]]
for inputs connection


* Status buttons:  These buttons work like the standard ones but they can be activated or de-activated. They are used for changing a state. An activated button is slightly darkened.
This section of the Vision tab offers a clear way to build or modify a measurement or post-analysis configuration. That covers the main steps of a measurement setup. These steps are respectively managed by the Acquisition, Analyses and Display/Graphs tabs.
* Examples:
[[Image:Reports_Tools_Ribbons_205.png|framed|none]]
that switches between on-line and post-analysis modes,<br> or
[[Image:Reports_Tools_Ribbons_206.png|framed|none]]
for enabling the marker manipulations.
* Settings: Provide a direct access to one of the ASB setting. Allow to continuously check the setup.


* Examples:
=====Tab & groups=====
The interface layer features 7 standard tabs (optional tab are also visibles). Each tab contains a set of groups which gathers settings, info and buttons about one topic (e.g. disk, FFT or transducers).


[[Image:Reports_Tools_Ribbons_207.png|framed|none]]
[[Image:Reports_Tools_Ribbons_202.png|framed|none]]


* Multi-actions:  These buttons works as the standard ones but it is possible to
=====Actions=====
select their action from a list.  When an action item is selected from the list, it became the default action of the button, the icon is changed.
The groups contain buttons, setting and check boxes of different types:


[[Image:Reports_Tools_Ribbons_208.png|framed|none]]
'''Buttons: ''' Left click on it leads to an action or opens a dialog box.


Examples are: Marker, or User selection.
Examples: [[Image:Usersmanual_122.png]]for auto scale or [[Image:Usersmanual_123.png]] for inputs connection


*
'''Status buttons: ''' These buttons work like the standard ones but they can be activated or de-activated. They are used for changing a state. An activated button is slightly darkened.
[[Image:Reports_Tools_Ribbons_04.png|framed|none]]


Status buttons: These buttons change and show the status of the active element (windows, trace, etc..). Selecting one of the item in their list will apply this status to the active element. The status buttons change depending on the applied changes to the element (or change of element). It is useful to monitor and see immediately in what state is a 3D or the active user for ex.
Examples:  
[[Image:Usersmanual_124.png]] that switches between '''on-line''' and '''post-analysis''' modes,<br> or[[Image:Usersmanual_125.png]]
for enabling the marker manipulations.


Note: The buttons are highlighted when the mouse pointer pass over an active button.


=====On line help on Vision ribbons=====
'''Settings: '''Provide a direct access to one of the ASB setting. Allow to continuously check the setup.
The content of the Vision™ ribbons are connected to the on-line help.


[[Image:Reports_Tools_Ribbons_209.png|framed|none]]
Examples: [[Image:Usersmanual_126.png]]for a numerical setting,[[Image:Usersmanual_127.png]]for a '''Boolean''' (checkbox),[[Image:Usersmanual_128.png]]for a selection in a list[[Image:Usersmanual_11.png]]


In order to get help from one of the Vision element, activate the help mode by clicking on the upper right question mark. The cursor switches to a pointer <nowiki>+</nowiki> pointer marks. Then click on the desired item. The corresponding page of the reference manual will be opened.
'''Multi-actions: ''' These buttons work as the standard ones but it is possible to select their action from a list. ''' '''When an action item is selected from the list, it becomes the default action of the button, the icon is changed.


Note that the latest pdf reader software are supported with NVGate V9.00: Acrobat reader 32 or 64 bits and Acrobat and any other pdf reader. The ability to open the manual at the corresponding pages is supported by Adobe™ products only. OROS recommend using acrobat reader using the on-line help functionality.
Examples are: Marker, or User selection.


=====Minimize ribbon and full screen=====
'''Status buttons: ''' These buttons change and show the status of the active element (windows, trace, etc..). Selecting one of the items in their list will apply this status to the active element. The status buttons change depending on the applied changes to the element (or change of element). It is useful to monitor and see immediately in what state is a 3D or the active user for example.
In order to gain space on the NVGate screen during acquisition and analysis the NVGate ribbon can be minimized. It operates like in the MS Office suite:


[[Image:Reports_Tools_Ribbons_210.png|framed|none]]
'''Note''': The buttons are highlighted when the mouse pointer pass over an active button.
Use the upper right arrow to minimize or reset the ribbon size. When the ribbon is minimized the tab header remains visible. Their content is accessible by clicking on the corresponding tab header.


The full screen function has been improved. It hides the application top bar as well as the windows bottom bar.
=====Status bar=====
At the bottom of the screen a fixed status bar maintains a continuous monitoring of the inputs and analysis:


[[Image:Reports_Tools_Ribbons_211.png|framed|none]]
[[Image:Usersmanual_129.png|framed|none]]


=====File Menu=====
See [[NVGate Status bar|status bar page]] for more info
A unique "File" menu is available on upper left for input/output file operation. It allows loading/saving setups and provides access to the on-line help


=====Status bar=====
=====On line help on Vision ribbons=====
At the bottom of the screen a fixed status bar maintain a continuous monitoring of the inputs and analysis:
The content of the Vision™ ribbons are connected to the on-line help.


[[Image:Reports_Tools_Ribbons_212.png|framed|none]]
[[Image:Usersmanual_130.png|framed|none]]


In order to get help from one of the Vision elements, activate the help mode by clicking on the upper right question mark. The cursor switches to a pointer <nowiki>+</nowiki> question mark. Then click on the desired item. The corresponding page of the reference manual will be opened.


====Tabs====
Note that the latest pdf reader software is supported with NVGate: Acrobat reader 32 or 64 bits and Acrobat and any other pdf reader. The ability to open the manual at the corresponding pages is supported by Adobe™ products only. OROS recommend using acrobat reader using the on-line help functionality.


====Operation with Vision====
=====Minimize ribbon and full screen=====
With Vision the software entries are organized in a logical operations way. There is 7 different tabs corresponding to 3 main operations type:
In order to gain space on the NVGate screen during acquisition and analysis the NVGate ribbon can be minimized. It operates like in the MS Office suite:


1. <font size = "4">Measure – Setup – Custom</font>
Use the upper right arrow to minimize or reset the ribbon size. When the ribbon is minimized the tab header remains visible. Their content is accessible by clicking on the corresponding tab header. The full screen function has been improved. It hides the application top bar as well as the windows bottom bar.


2. <font size = "4">Measurements</font>
[[Image:Usersmanual_131.png|framed|none]]


The principal goal the instrument is to measure noise and vibrations. The tabs corresponding to such operations are gathered at the top left of the interface: Home & Measurements.
=====Log window=====


3. <font size = "4">Setup and fine tuning</font>
[[Image:Usersmanual_132.png|framed|none]]


This section of the Vision tab offers a clear way to build or modify a measurement or post-analysis configuration. That covers the main steps of a measurement setup. These steps are respectively managed by the Acquisition, Analyses and Display/Graphs tabs.
In the Home tab, tick/untick the Log window
[[Image:Usersmanual_133.png|framed|none]]
to show/hide the Log window (Analyzer settings, Warning and Macro Trace information).


===File Menu===
===File Menu===
Line 124: Line 129:
After being saved, the model remains unchanged whatever the number of time it is used. In order to change a model it must be loaded, modified and saved as a model again with the same name.
After being saved, the model remains unchanged whatever the number of time it is used. In order to change a model it must be loaded, modified and saved as a model again with the same name.


====Export====
[[Image:Reports_Tools_Ribbons_503.jpg|framed|none]]
=====Result files=====
Export results from the project manager to a user specified directory in various data format.
[[Image:Reports_Tools_Ribbons_504.png|framed|none]]
Project: Lists the projects that contain measurements. Only one project can be selected.
Measurement: Lists the measurements in the project selected. Select one or several measurements and click on the add button.
Batch list: Contains all the measurements that will be converted. Use the add/remove button to modify list content.
Format: This is the output format. The formats available are:
{|border="2" cellspacing="0" cellpadding="4" width="84%" align="center"
|Result
|Signal
|-
|Mat: to be used with Matlab
|Mat: to be used with Matlab
|-
|Txt: usable by any text or spreadsheet editor
|SDF: Standard data format
|-
|UFF: Universal File Format
|UFF: Universal File Format
|-
|&nbsp;
|Wav audio: Wav file, re-sampled to standard audio frequency (44.1, 48, 96 kHz) . To be used by any audio player
|-
|&nbsp;
|Wav: Standard wav format, usable with OR2X technology
|-
|&nbsp;
|Txt: Text usable by any text or spreadsheet editor
|}<br clear="all">
''See Chapter 7 User preferences- § Export" topic for more details''
Output directory: The location on the disk where the files will be exported. During the export, a directory will be created for each project, and will contain the exported files corresponding to all selected measurements.
=====Signals files=====
Export Signal from the project manager records to a user specified directory in various data format.
''See details from previous § Export result files''
====Import====
[[Image:Reports_Tools_Ribbons_505.jpg|framed|none]]
=====Import project=====
This command is used to import project that are not in the project database. It makes a copy of the project and makes it available to the current user, or whoever created the project. If a project already exists in the project base, a <nowiki>~</nowiki> (tilde) will automatically be added.
Directory: Select the directory in which you would like to look for the project. The "found project" list will display all projects that are immediately in the directory selected. If the "scan" button is pressed, all the projects that are contained in the specified directory will be displayed.
Found projects: Displays the list of projects found. Select one or several projects to import.
=====Import Files=====
This command is used to import results or signals. It makes a copy of the file and makes it available to the current user, or whoever created the file. The file will be included in a measurement If a measurement already exists in the project, a <nowiki>~</nowiki> (tilde) will automatically be appended.
[[Image:Reports_Tools_Ribbons_506.png|framed|none]]
* Reception project: Determines which project will receive the new measurement
* File type: One or several types can be selected. File type may be OR2X or OR3X
* Directory: Selects the directory in which you would like to look for the files. The "found files" list will display all the files that are immediately in the directory selected. If the "scan" button is pressed, all the files that are contained in the specified directory will be displayed.
* Found files: Displays the list of files found. Select one or several projects to import.
====Recent projects====
====Recent projects====
Displays the list of the most recent projects used by the current user.
Displays the list of the most recent projects used by the current user.
Line 227: Line 158:


----
----
===Shortcuts===
====General shortcuts====
{|border="2" cellspacing="0" cellpadding="4" width="101%"
|F1
|On-Line Help
|-
|Ctrl <nowiki>+</nowiki> Space
|Move from one layout to the next one
|-
|Ctrl <nowiki>+</nowiki> Tab
|Move from one window to another one in the same layout
|-
|Page Up
|Change Workspace tab (ASB, Control Panel, Project Manager)
|-
|Page Down
|Change Workspace tab (ASB, Control Panel, Project Manager)
|-
|F10
|Freeze the active window
|-
|
[[Image:Reports_Tools_Ribbons_507.png|framed|none]]
|Move the cursor to the left
|-
|
[[Image:Reports_Tools_Ribbons_508.png|framed|none]]
|Move the cursor to the right
|-
|<nowiki>+</nowiki>
|Zoom in on Y axis
|-
|<nowiki>-</nowiki>
|Zoom out on Y axis
|-
|/
|Zoom out on X axis
|-
|<nowiki>*</nowiki><br>
|Zoom in on X axis
|-
|Shift <nowiki>+</nowiki> F1
|Contextual help
|-
|Ctrl <nowiki>+</nowiki> Insert
|Edit Copy
|-
|Shift <nowiki>+</nowiki> Delete
|Edit Cut
|-
|Ctrl <nowiki>+</nowiki> X
|Edit Cut
|-
|Shift <nowiki>+</nowiki> Insert
|Edit Paste
|-
|Alt <nowiki>+</nowiki> Back
|Edit Undo
|-
|&nbsp;
|&nbsp;
|-
|Ctrl <nowiki>+</nowiki> R
|Run
|-
|Pause
|Pause
|-
|Ctrl <nowiki>+</nowiki> S
|Stop
|-
|Ctrl <nowiki>+</nowiki> A
|Y axis auto-scale on all windows
|-
|Crtl <nowiki>+</nowiki> Alt <nowiki>+</nowiki> A
|Y axis auto-scale on active window
|-
|Ctrl <nowiki>+</nowiki> Shift <nowiki>+</nowiki> A
|Auto-range
|-
|Ctrl <nowiki>+</nowiki> B
|Next Step
|-
|Ctrl <nowiki>+</nowiki> C
|Copy item content (ASB settings, mask)
|-
|Ctrl <nowiki>+</nowiki> V
|Paste item content (ASB settings, mask)
|-
|Ctrl <nowiki>+</nowiki> D
|Save current workbook
|-
|Ctrl <nowiki>+</nowiki> Y
|Accept acquisition
|-
|Ctrl <nowiki>+</nowiki> N
|Reject acquisition
|-
|Ctrl <nowiki>+</nowiki> 0 to 9
|Macro start
|-
|Ctrl <nowiki>+</nowiki> P
|Print report
|-
|Ctrl <nowiki>+</nowiki> Q
|Zoom auto-scale on Z axis
|-
|Ctrl <nowiki>+</nowiki> T
|Manual trigger
|-
|Ctrl <nowiki>+</nowiki> M
|Add record marker
|-
|Ctrl <nowiki>+</nowiki> W or Z
|Full width on active trace
|-
|Insert
|Memorize Trace
|-
|Ctrl <nowiki>+</nowiki> Delete
|Remove Active Trace
|-
|Ctrl <nowiki>+</nowiki> F5, F6, F7, F8, F9, F10
|Change the mouse mode (display mode toolbar)
|-
|X/Y/Z <nowiki>+</nowiki>Shift <nowiki>+</nowiki> Mouse wheel (up)
|Zoom in on (X/Y/Z) axis (<nowiki>+</nowiki> Ctrl for small steps)
|-
|X/Y/Z <nowiki>+</nowiki>Shift <nowiki>+</nowiki> Mouse wheel (down)
|Zoom out on (X/Y/Z) axis (<nowiki>+</nowiki> Ctrl for small steps)
|-
|X/Y/Z <nowiki>+</nowiki> Mouse wheel (up)
|Translate X/Y/Z axis positively (<nowiki>+</nowiki> Ctrl for small steps)
|-
|X/Y/Z <nowiki>+</nowiki> Mouse wheel (down)
|Translate X/Y/Z axis negatively (<nowiki>+</nowiki> Ctrl for small steps)
|-
|Ctrl <nowiki>+</nowiki> F5
|Default mode activation (scale mode)
|-
|Ctrl <nowiki>+</nowiki> F6
|Zoom mode activation
|-
|Ctrl <nowiki>+</nowiki> F7
|Cursor mode activation
|-
|Ctrl <nowiki>+</nowiki> F8
|Move mode activation
|-
|Ctrl <nowiki>+</nowiki> F9
|Rotate mode activation
|-
|Ctrl <nowiki>+</nowiki> F10
|Marker mode activation
|-
|F2 to F9, F11, F12
|Macro Hot key
|}
====Use the mouse wheel for 1D windows====
Mouse wheel: move the min, the max or shift a scale.
Note: If you do not have a mouse wheel, you can use the top and bottom arrows
====Template Editor====
{|border="2" cellspacing="0" cellpadding="4" width="100%"
|Tab
|Browse the objects on the active page
|-
|Alt Gr <nowiki>+</nowiki> Tab
|Browse the objects on the active page in the opposite direction
|-
|Alt <nowiki>+</nowiki> Enter
|Last selected object properties
|-
|
[[Image:Reports_Tools_Ribbons_509.png|framed|none]]
|Move one or several selected controls to the left
|-
|
[[Image:Reports_Tools_Ribbons_510.png|framed|none]]
|Move one or several selected controls to the right
|-
|
[[Image:Reports_Tools_Ribbons_511.png|framed|none]]
|Move one or several selected controls to the top
|-
|
[[Image:Reports_Tools_Ribbons_512.png|framed|none]]
|Move one or several selected controls to the bottom
|-
|Suppr
|Delete one or several selected controls
|}
====Use the mouse wheel for 2D windows====
====Cursor mode====
Mouse Wheel: right/left move by 5 steps.
Mouse Wheel <nowiki>+</nowiki> CTRL: right/left move by 1 step.
====Arrow mode====
When the pointer is on the X or Y axis and on the min or max value, use the mouse wheel to move 5 pixels.
When the pointer is on the X or Y axis and on the min or max value, use the mouse wheel <nowiki>+</nowiki> CRTL to move 1 pixel.
When the pointer is in the middle of X or Y axis, use the mouse wheel to shift translation of the zoom area 5 pixels.
When the pointer is in the middle of the X or Y axis, use the mouse wheel <nowiki>+</nowiki> CRTL to shift of the zoom area 1 pixel.
When the pointer is in the middle of X or Y axis, use the mouse wheel <nowiki>+</nowiki> SHIFT to zoom quickly.
When the pointer is in the middle of X or Y axis, use the mouse wheel <nowiki>+</nowiki> CRTL <nowiki>+</nowiki> SHIFT to zoom.
----
----
<references/>

Latest revision as of 07:51, 25 September 2020


Interface Overview and Ribbon description

Usersmanual 120.png


More information on the dedicated page :
Vision Tab
Windows: Graph - trace - infotrace
Analyzer setting browser
Control Pannel
Project manager
Status Bar
Go to result

Vision Tab

The Vision interface gathers the analyzers functionalities in simple, clear and easy to identify tabs organized according to the main operations (First steps, measuring, results edition, configuration build-up, automation, general setup etc…).

Key features have been emphasized by the Vision interface, guiding the users to the best way using their OROS 3-Series analyzer.

Operation with Vision

With Vision the software entries are organized in a logical operations way. There is 7 different tabs corresponding to 3 main operations type:

1. Measure – Setup – Custom

2. Measurements

The principal goal the instrument is to measure noise and vibrations. The tabs corresponding to such operations are gathered at the top left of the interface: Home & Measurements.

3. Setup and fine tuning

This section of the Vision tab offers a clear way to build or modify a measurement or post-analysis configuration. That covers the main steps of a measurement setup. These steps are respectively managed by the Acquisition, Analyses and Display/Graphs tabs.

Tab & groups

The interface layer features 7 standard tabs (optional tab are also visibles). Each tab contains a set of groups which gathers settings, info and buttons about one topic (e.g. disk, FFT or transducers).

Reports Tools Ribbons 202.png
Actions

The groups contain buttons, setting and check boxes of different types:

Buttons: Left click on it leads to an action or opens a dialog box.

Examples: Usersmanual 122.pngfor auto scale or Usersmanual 123.png for inputs connection

Status buttons: These buttons work like the standard ones but they can be activated or de-activated. They are used for changing a state. An activated button is slightly darkened.

Examples: Usersmanual 124.png that switches between on-line and post-analysis modes,
orUsersmanual 125.png for enabling the marker manipulations.


Settings: Provide a direct access to one of the ASB setting. Allow to continuously check the setup.

Examples: Usersmanual 126.pngfor a numerical setting,Usersmanual 127.pngfor a Boolean (checkbox),Usersmanual 128.pngfor a selection in a listUsersmanual 11.png

Multi-actions: These buttons work as the standard ones but it is possible to select their action from a list. When an action item is selected from the list, it becomes the default action of the button, the icon is changed.

Examples are: Marker, or User selection.

Status buttons: These buttons change and show the status of the active element (windows, trace, etc..). Selecting one of the items in their list will apply this status to the active element. The status buttons change depending on the applied changes to the element (or change of element). It is useful to monitor and see immediately in what state is a 3D or the active user for example.

Note: The buttons are highlighted when the mouse pointer pass over an active button.

Status bar

At the bottom of the screen a fixed status bar maintains a continuous monitoring of the inputs and analysis:

Usersmanual 129.png

See status bar page for more info

On line help on Vision ribbons

The content of the Vision™ ribbons are connected to the on-line help.

Usersmanual 130.png

In order to get help from one of the Vision elements, activate the help mode by clicking on the upper right question mark. The cursor switches to a pointer + question mark. Then click on the desired item. The corresponding page of the reference manual will be opened.

Note that the latest pdf reader software is supported with NVGate: Acrobat reader 32 or 64 bits and Acrobat and any other pdf reader. The ability to open the manual at the corresponding pages is supported by Adobe™ products only. OROS recommend using acrobat reader using the on-line help functionality.

Minimize ribbon and full screen

In order to gain space on the NVGate screen during acquisition and analysis the NVGate ribbon can be minimized. It operates like in the MS Office suite:

Use the upper right arrow to minimize or reset the ribbon size. When the ribbon is minimized the tab header remains visible. Their content is accessible by clicking on the corresponding tab header. The full screen function has been improved. It hides the application top bar as well as the windows bottom bar.

Usersmanual 131.png
Log window
Usersmanual 132.png

In the Home tab, tick/untick the Log window

Usersmanual 133.png

to show/hide the Log window (Analyzer settings, Warning and Macro Trace information).

File Menu

Project

Reports Tools Ribbons 501.jpg
New

Opens the Start & Go. This dialog proposes to load predefined setups or to build a new one. See § Tabs/Home in this chapter for details

Load

Opens the dialog box to load a project. Select a project from the current base.

Save:

Saves the current project. If the current project is the default project, the Save command will act as the Save As.

Save As:

Saves the current project with a new name

Save setup as model

Reports Tools Ribbons 502.jpg

Save the current setup in the C:\OROS\NVGate data\Workbook Library\user Directory. The models can be reloaded from the Load setup button in the Home Tab.

A Model includes the following items:

  • Workbook
  • ASB
  • Layouts
  • Control panel
  • Save Setup
  • Macros
  • Sequences
  • Signal file loaded in the player

After being saved, the model remains unchanged whatever the number of time it is used. In order to change a model it must be loaded, modified and saved as a model again with the same name.

Recent projects

Displays the list of the most recent projects used by the current user.

Recent measurements

Displays the list of the most recent measurements used by the current user.

Help

Users’ manual

Load the users’ manual. Acrobat reader must be installed on the PC.

The user manual gathers all the guides and rules to uses the analyzer from its installation to advanced automated operations. It answer to the "How do I?" question.

Reference manual

Load the reference manual. Acrobat reader must be installed on the PC.

The reference manual contains the detailed description of each item of the analyzer. It can be loaded with the F1 key on any Item.

What’s new

Load the release note of the current NVGate version. Acrobat reader must be installed on the PC.

This is helpful identifying the latest features or getting instruction of items which are not already available in the reference manual

Web

Shortcuts to the OROS pages on the web. The myOROS website gathers many helpful information and example dedicated to OROS products users. Register on www.myOROS.com

Exit

Exit NVGate.