1,042
edits
Line 420: | Line 420: | ||
* '''Trigger''': selects the event that trigs waterfall acquisitions. This setting selects the event which trig acquisitions that is to say a new data collection occur each time trigger event occurred. If trigger is set to periodic (period 20ms) the Waterfall acquisition will operate as fast as possible, this can hang user interface during acquisitions. The first time a source is selected for the Waterfall, if trigger = Periodic, then the event corresponding to the availability of the source results is assigned to the trigger. Ex: Setting FFT1 spectra into the waterfall plug-in will set Trigger to <nowiki>’</nowiki>FFT1 result available<nowiki>’</nowiki>. By default the trigger is set to <nowiki>’</nowiki>Periodic<nowiki>’</nowiki> with a period of 20. | * '''Trigger''': selects the event that trigs waterfall acquisitions. This setting selects the event which trig acquisitions that is to say a new data collection occur each time trigger event occurred. If trigger is set to periodic (period 20ms) the Waterfall acquisition will operate as fast as possible, this can hang user interface during acquisitions. The first time a source is selected for the Waterfall, if trigger = Periodic, then the event corresponding to the availability of the source results is assigned to the trigger. Ex: Setting FFT1 spectra into the waterfall plug-in will set Trigger to <nowiki>’</nowiki>FFT1 result available<nowiki>’</nowiki>. By default the trigger is set to <nowiki>’</nowiki>Periodic<nowiki>’</nowiki> with a period of 20. | ||
{|border="2" cellspacing="0" cellpadding="4" width="100%" align="center" | {|class="wikitable" style="background:white" border="2" cellspacing="0" cellpadding="4" width="100%" align="center" | ||
|'''List of events''' | |'''List of events''' | ||
|'''Description''' | |'''Description''' | ||
Line 458: | Line 458: | ||
* The analyzer is running, it keeps in memory last measurements. Then with the waterfall you can select some specific results (for example for rpm or time). | * The analyzer is running, it keeps in memory last measurements. Then with the waterfall you can select some specific results (for example for rpm or time). | ||
* The plug-in triggering, at the end of each average the plug-in send an event. The plug-in put the rhythm into the waterfall. This mode is the default mode. | * The plug-in triggering, at the end of each average the plug-in send an event. The plug-in put the rhythm into the waterfall. This mode is the default mode. | ||
=====Mode===== | =====Mode===== | ||
Contains the settings related to the Waterfall display mode. | Contains the settings related to the Waterfall display mode. |