1,042
edits
Line 380: | Line 380: | ||
'''Tach:''' On / Off. Used to activate a tachometer with an RPM level proportional to the DC level. | '''Tach:''' On / Off. Used to activate a tachometer with an RPM level proportional to the DC level. | ||
Rotation: Depending on the way you look at a measured shaft or on the convention you are using, the shaft may be considered as rotating | Rotation: Depending on the way you look at a measured shaft or on the convention you are using, the shaft may be considered as rotating clockwise or counterclockwise. This has noticeable impact on the phase of spectra and orders. | ||
''Hidden/fixed: Hidden if Tach is Off.'' | ''Hidden/fixed: Hidden if Tach is Off.'' | ||
Line 393: | Line 393: | ||
* To compute the limit of the maximum order of the SOA plug-in analyzer. | * To compute the limit of the maximum order of the SOA plug-in analyzer. | ||
'''Min speed''': defines the lowest measured angular speed. All revolutions with a speed lower than Min speed are forced to 0 RPM. By default Min speed is expressed in RPM. Min speed is automatically adjusted to Max speed/1000 but it is possible to go lower. | '''Min speed''': defines the lowest measured angular speed. All revolutions with a speed lower than Min speed are forced to 0 RPM. By default Min speed is expressed in RPM. Min speed is automatically adjusted to Max speed/1000 but it is possible to go lower. | ||
* '''Rotation:''' This setting defines the way the phase variation is counted: clockwise or | * '''Rotation:''' This setting defines the way the phase variation is counted: clockwise or counterclockwise for each tachometer. | ||
The rotation side is managed independently for each tachometer (Ext. sync, input, D, combined and fractional). Default setup is ''Counterclockwise''; | The rotation side is managed independently for each tachometer (Ext. sync, input, D, combined and fractional). Default setup is ''Counterclockwise''; |