Difference between revisions of "NVGate 2021: Release note fr"

Jump to navigation Jump to search
Line 336: Line 336:
|-
|-
|style="height:30px; width:100px;"|<math>A_w</math>  
|style="height:30px; width:100px;"|<math>A_w</math>  
|Daily maximal exposure value (Calculated from Post processing in NVGate)
|Daily maximal exposure value (calculé en post-analyse avec NVGate)
|-
|-
|style="height:30px; width:100px;"|<math>Peak</math>  
|style="height:30px; width:100px;"|<math>Peak</math>  
|Amplitude Peak of the vibration; maximal amplitude of the signal from the 0 (Calculated from Post processing in NVGate)
|Amplitude Peak of the vibration; amplitude Peak maximale du signal (calculé en post-analyse avec NVGate)
|-
|-
|style="height:30px; width:100px;"|<math>Crest factor</math>  
|style="height:30px; width:100px;"|<math>Crest factor</math>  
|Ratio between the Peak level and the RMS of the weighted signal(Calculated from Post processing in NVGate)
|Rapport entre le niveau Peak et la valeur RMS du signal pondéré (calculé en post-analyse avec NVGate)
|}
|}


Line 350: Line 350:
|-
|-
|style="height:30px; width:100px;"|<math>W_k</math>
|style="height:30px; width:100px;"|<math>W_k</math>
|Time weighting for the Z axis for whole-body measurement (ISO 2631-1)
|Pondération temporelle pour l'axe Z pour les mesures sur l'ensemble du corps (ISO 2631-1)
|-
|-
|style="height:30px; width:100px;"|<math>W_d</math>  
|style="height:30px; width:100px;"|<math>W_d</math>  
|Time weighting for the X and Y axis for whole-body measurement (ISO 2631-1)
|Pondération temporelle pour les axes X et Y pour les mesures sur l'ensemble du corps (ISO 2631-1)
|-
|-
|style="height:30px; width:100px;"|<math>W_h</math>
|style="height:30px; width:100px;"|<math>W_h</math>
|Time weighting for the hand-arms measurement in any direction (ISO 5349-1)  
|Pondération temporelle pour les mesures mains/bras dans toutes les directions (ISO 5349-1)  
|-
|-
|style="height:30px; width:100px;"|<math>W_f</math>
|style="height:30px; width:100px;"|<math>W_f</math>
|Time weighting for motion sickness measurement in the vertical direction (ISO 2631-1)  
|Pondération temporelle pour les mesures du confort dans les moyens de transports dans la direction verticale (ISO 2631-1)  
|-
|-
|style="height:30px; width:100px;"|<math>W_c</math>
|style="height:30px; width:100px;"|<math>W_c</math>
|Time weighting for the X axis for whole-body measurement (ISO 2631-1)
|Pondération temporelle dans l'axe X pour les mesures sur l'ensemble du corps (ISO 2631-1)
|-
|-
|style="height:30px; width:100px;"|<math>W_e</math>  
|style="height:30px; width:100px;"|<math>W_e</math>  
|Time weighting for all rotational directions for whole-body measurement (ISO 2631-1)  
|Pondération temporelle pour toutes les directions rotationnelles pour les mesures sur l'ensemble du corps (ISO 2631-1)  
|-
|-
|style="height:30px; width:100px;"|<math>W_j</math>
|style="height:30px; width:100px;"|<math>W_j</math>
|Time weighting for the Z axis for head comfort measurement (ISO 2631-1)
|Pondération temporelle pour l'axe Z axis pour les mesures du confort de la tête (ISO 2631-1)
|}
|}


Comment l'utiliser:
'''Comment l'utiliser:'''
https://wiki.oros.com/wiki/index.php/Human_Vibration
https://wiki.oros.com/wiki/index.php/Human_Vibration


Navigation menu