Difference between revisions of "NVGate Filter Builder"

Jump to navigation Jump to search
Line 73: Line 73:
* '''Filter order''': The filter order is 2*N, and N can be selected between 1 to 30 in the Office mode, and between 1 to 10 in the Connected mode. The higher the order is, the steeper the cut-off slope is.
* '''Filter order''': The filter order is 2*N, and N can be selected between 1 to 30 in the Office mode, and between 1 to 10 in the Connected mode. The higher the order is, the steeper the cut-off slope is.
* '''Applied to''': Shows which plug-in the filter is applied to. The construction of the filter requires applying it to a signal with the same bandwidth. The determination of the associated plug-in/bandwidth is automatic. Deactivate the filter to reset.
* '''Applied to''': Shows which plug-in the filter is applied to. The construction of the filter requires applying it to a signal with the same bandwidth. The determination of the associated plug-in/bandwidth is automatic. Deactivate the filter to reset.
The other modules (front-end, monitor, resources) operate at the front end input sampling frequency (in connected mode on-line) or at the max player bandwidth (in post analysis mode).
: The other modules (front-end, monitor, resources) operate at the front end input sampling frequency (in connected mode on-line) or at the max player bandwidth (in post analysis mode).


{|border="2" cellspacing="0" cellpadding="4" width="59%" align="center"
{|border="2" cellspacing="0" cellpadding="4" width="59%" align="center"
Line 89: Line 89:
|}<br clear="all">
|}<br clear="all">


Note that even if plug-ins run in the same bandwidth, it’s not possible to share filters between different plug-ins.
: Note that even if plug-ins run in the same bandwidth, it’s not possible to share filters between different plug-ins.


* '''Low cut-off frequency''' and '''High cut-off frequency''': The low cut-off frequency of the filter ''f''<sub>low</sub> and the high cut-off frequency of the filter ''f''<sub>high</sub>. Their values need to meet the following conditions in the Office mode:
* '''Low cut-off frequency''' and '''High cut-off frequency''': The low cut-off frequency of the filter ''f''<sub>low</sub> and the high cut-off frequency of the filter ''f''<sub>high</sub>. Their values need to meet the following conditions in the Office mode:


''f''<sub>low</sub> ≥ 0.0001 * '''FR'''  
: ''f''<sub>low</sub> ≥ 0.0001 * '''FR'''  
   
   
''f''<sub>high</sub> ≤ '''FR'''   
: ''f''<sub>high</sub> ≤ '''FR'''   


0.0004 '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.9998 * '''FR'''
: 0.0004 '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.9998 * '''FR'''


And in the Connected mode, the conditions are as below:
: And in the Connected mode, the conditions become as below:


''f''<sub>low</sub> ≥ 0.0005 * '''FR'''
: ''f''<sub>low</sub> ≥ 0.0005 * '''FR'''


''f''<sub>high</sub> ≤ '''FR'''
: ''f''<sub>high</sub> ≤ '''FR'''


0.000675 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR'''
: 0.000675 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR'''


where '''FR''' is the input frequency range.  
: where '''FR''' is the input frequency range.  


* '''By'''-'''pass''': On / Off. The filter is not applied if By-pass is On.
* '''By'''-'''pass''': On / Off. The filter is not applied if By-pass is On.