== DC Dynamical sensor y = ax+b calibration ==
== DC Dynamical sensor y = ax+b calibration ==




It is now possible to calibrate a dynamical sensor in "DC" or "DC floating" coupling using 2 values, then the software will automatically compute sensitivity and offset to obtaine the  "y = ax + b" formula.
It is now possible to calibrate a dynamical sensor in "DC" or "DC floating" coupling using 2 values, then the software will automatically compute sensitivity and offset to obtain the  "y = ax + b" formula.




This function is practical for 4-20 mA sensors or “quasi-static” sensors acquired on dynamic channels.  wire sensor displacement sensor calibrated with a rule, pressure sensor with a calibrated compressor, proximity probe calibrated with a micrometer.
This function is practical for 4-20 mA sensors or “quasi-static” sensors acquired on dynamic channels.  Wire sensor displacement sensor calibrated with a rule, pressure sensor with a calibrated compressor, proximity probe calibrated with a micrometer.


For using it, first create a DC sensor on the sensor database. Then apply this sensor to a channels.
For using it, first create a DC sensor on the sensor database. Then apply this sensor to a channel.


Now on the calibration part, you can calibrate it using 2 values. Then the software will automatically and apply the sensitivity and offset.
Now on the calibration part, you can calibrate it using 2 values. Then the software will automatically apply the sensitivity and offset.


[[File:calibrator.png|600px]]
[[File:calibrator.png|600px]]
Line 299: Line 299:
== Remove a sensor from history ==
== Remove a sensor from history ==


If you have done a mistake during a sensor calibration, you can now delete a value from calbration sensor historic.
If you have done a mistake during a sensor calibration, you can now delete a value from calbiration sensor history.
[[File:remove_caibration.png|800px]]
[[File:remove_caibration.png|800px]]


You need to ho on historic , select the sensor, select the value that you need to delete , then click on remove.
You need to go on history, select the sensor, select the value that you need to delete, then click on remove.