Line 42: | Line 42: | ||
For the band pass and band stop filters, the low cut-off frequency ''f''<sub>low</sub> and the high cut-off frequency ''f''<sub>high</sub> need to meet the following conditions in the Office mode: | For the band pass and band stop filters, the low cut-off frequency ''f''<sub>low</sub> and the high cut-off frequency ''f''<sub>high</sub> need to meet the following conditions in the Office mode: | ||
* | * ''f''<sub>low</sub> ≥ 0.0001 * '''FR''' | ||
* ''f''<sub>high</sub> ≤ '''FR''' | * ''f''<sub>high</sub> ≤ '''FR''' | ||
Line 50: | Line 50: | ||
And in the Connected mode, the conditions are as below: | And in the Connected mode, the conditions are as below: | ||
* | * ''f''<sub>low</sub> ≥ 0.0005 * '''FR''' | ||
* ''f''<sub>high</sub> ≤ '''FR''' | * ''f''<sub>high</sub> ≤ '''FR''' | ||
* 0.000675 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR''' | * 0.000675 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR''' | ||
In the previous version of NVGate, the conditions on the cut-off frequencies are: | |||
* ''f''<sub>low</sub> ≥ 0.055 * '''FR''' | |||
* ''f''<sub>high</sub> ≤ '''FR''' | |||
* 0.0075 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR''' | |||
==Improved precision== | ==Improved precision== |