Line 36: | Line 36: | ||
To guarantee the stability of the filter, there are certain constraints on the value of the cut-off frequency. Compared with previous version of NVGate, such constraints are relaxed significantly now. | To guarantee the stability of the filter, there are certain constraints on the value of the cut-off frequency. Compared with previous version of NVGate, such constraints are relaxed significantly now. | ||
[[File: | [[File:image_2020-11-27_095451.png|600px]] | ||
For the high pass and low pass filters, the maximum value of the cut-off frequency is the input frequency range '''FR'''. The minimum value is '''FR''' / 50000 in Office mode, and '''FR''' / 40000 in Connected mode. In previous version of NVGate, the minimum value is '''FR''' / 40 for the low pass filter, and '''FR''' / 400 for the high pass filter. | For the high pass and low pass filters, the maximum value of the cut-off frequency is the input frequency range '''FR'''. The minimum value is '''FR''' / 50000 in Office mode, and '''FR''' / 40000 in Connected mode. In previous version of NVGate, the minimum value is '''FR''' / 40 for the low pass filter, and '''FR''' / 400 for the high pass filter. |