Difference between revisions of "NVGate Transducer and Calibration"

Jump to navigation Jump to search
Line 73: Line 73:
* Default coupling: default coupling value that will be used when a new transducer is created. This value can be changed individually.
* Default coupling: default coupling value that will be used when a new transducer is created. This value can be changed individually.
* Comment: Free text area
* Comment: Free text area
*  
* [[Image:Reports_Tools_Ribbons_260.png|none]] History:
[[Image:Reports_Tools_Ribbons_260.png|framed|none]]
History:
This tool is used to see how transducer sensitivity and offset change over time. Information about every calibration is displayed, making it easy for the user to see if the transducer behavior is constant.
This tool is used to see how transducer sensitivity and offset change over time. Information about every calibration is displayed, making it easy for the user to see if the transducer behavior is constant.


Line 86: Line 84:
It is used to select the sensitivity graph, the offset graph or both. It is also possible to hide/display the factory values. There is also a marker to highlight the calibration.
It is used to select the sensitivity graph, the offset graph or both. It is also possible to hide/display the factory values. There is also a marker to highlight the calibration.


*  
* [[Image:Reports_Tools_Ribbons_262.png]] Merge  multiple transducer databases into one. The merged TDB is the one currently used by NVGate (file: ''transducers.tdb'' located in the ''NVGate.exe'' directory)
[[Image:Reports_Tools_Ribbons_262.png]]
Merge  multiple transducer databases into one. The merged TDB is the one currently used by NVGate (file: ''transducers.tdb'' located in the ''NVGate.exe'' directory)
Clicking on ''Merge'' open the database to merge browser. Both native (.cdb) and comma separated values (.txt) formats are available. For the csv, the format is the same as the export one, with one line per transducer.
Clicking on ''Merge'' open the database to merge browser. Both native (.cdb) and comma separated values (.txt) formats are available. For the csv, the format is the same as the export one, with one line per transducer.


In case of conflict (the same transducer does not features the same setup in the 2 databases) a specific dialog box is proposed.
In case of conflict (the same transducer does not features the same setup in the 2 databases) a specific dialog box is proposed.


[[Image:Reports_Tools_Ribbons_263.png|framed|none]]
[[Image:Reports_Tools_Ribbons_263.png|700px|none]]


Only conflict lines are displayed.
Only conflict lines are displayed.
Line 111: Line 107:
[[Image:Reports_Tools_Ribbons_264.png|framed|none]]
[[Image:Reports_Tools_Ribbons_264.png|framed|none]]


*  
* [[Image:Reports_Tools_Ribbons_265.png]] Export:  Allows exporting the current database (file: ''transducers.tdb'' located in the ''NVGate.exe'' directory) in csv format.
[[Image:Reports_Tools_Ribbons_265.png]]
Export:  Allows exporting the current database (file: ''transducers.tdb'' located in the ''NVGate.exe'' directory) in csv format.


The exported file contains one line per transducer with the following field.
The exported file contains one line per transducer with the following field.


[[Image:Reports_Tools_Ribbons_266.png|framed|none]]
[[Image:Reports_Tools_Ribbons_266.png|700px|none]]


Only the latest site calibration information are exported in the txt file.
Only the latest site calibration information are exported in the txt file.

Navigation menu