'''Standards compatible''': international standards about whole/body vibration including: ISO 5349, ISO 8041, ISO 2631-1 and ISO 2631-5.<br>
'''Standards compatible''': international standards about whole/body vibration including: ISO 5349, ISO 8041, ISO 2631-1 and ISO 2631-5.<br>


'''Parameters compute''':  VDV, MSDV, MTVV, Weighted raw, al(ISO 2631-5), D(ISO 2631-5) are available.  RMS, Peak, Crest, peak-Peak, are also available in NVGate plug in.
'''Whle/body Vibration Indicatiors include ''':  VDV, MSDV, MTVV, Weighted raw, al(ISO 2631-5), D(ISO 2631-5) are available.  RMS, Peak, Crest, peak-Peak, are also available in NVGate plug in.
 
{| class="wikitable" style="margin: auto;"
{| class="wikitable" style="margin: auto;"
|+style="caption-side:bottom;"|''Time-weighting filters''
|+style="caption-side:bottom;"|''Body vibration indicators''
|-
|-
|style="height:30px; width:100px;"|<math>W_k</math>
|style="height:30px; width:100px;"|<math>A_w</math>  
|Time weighting for the Z axis for whole-body measurement (ISO 2651-1)
|Daily maximal exposure value (Calculated from Post processing in NVGate)
|-
|-
|style="height:30px; width:100px;"|<math>W_d</math>  
|style="height:30px; width:100px;"|<math>Peak</math>  
|Time weighting for the X and Y axis for whole-body measurement (ISO 2651-1)
|Amplitude Peak of the vibration; maximal amplitude of the signal from the 0 (Calculated from Post processing in NVGate)
|-
|-
|style="height:30px; width:100px;"|<math>W_h</math>
|style="height:30px; width:100px;"|<math>Crest factor</math>  
|Time weighting for the hand-arms measurement in any direction (ISO 5349-1)  
|Ratio between the Peak level and the RMS of the weighted signal(Calculated from Post processing in NVGate)
|-
|-
|style="height:30px; width:100px;"|<math>W_f</math>
|style="height:30px; width:100px;"|<math>MTVV</math>
|Time weighting for motion sickness measurement in the vertical direction (ISO 2651-1)
|Maximum Transient Vibration Value, represent the maximal RMS value of the signal
|-
|-
|style="height:30px; width:100px;"|<math>W_c</math>
|style="height:30px; width:100px;"|<math>VDV</math>
|Time weighting for the X axis for whole-body measurement (ISO 2651-1)
|Vibration Dose Value, taking into account the temporal shocks in the signal
|-
|-
|style="height:30px; width:100px;"|<math>W_e</math>  
|style="height:30px; width:100px;"|<math>MSDV</math>
|Time weighting for all rotational directions for whole-body measurement (ISO 2651-1)
|Motion Sickness Dose Value, representing the comfort in transportation measurement
|-
|-
|style="height:30px; width:100px;"|<math>W_j</math>
|style="height:30px; width:100px;"|<math>D_k</math>  
|Time weighting for the Z axis for head comfort measurement (ISO 2651-1)
|The Acceleration Dose, representing the affect of the vibration on the spine
|}
|}