Difference between revisions of "NVGate 2021: Release note"

Jump to navigation Jump to search
Line 133: Line 133:


= Add on : Human body vibration =  
= Add on : Human body vibration =  
Add on :  filter time signal with Wk, Wd, Wh ponderation https://wiki.oros.com/wiki/index.php/Human_Vibration
 
STANDARDS compatible: The body Vib add on compute whole/body vibration according to international standards ISO 5349, ISO 8041, ISO 2631-1 and ISO 2631-5.
 
parameters computeVDV, MSDV, MTVV, Weighted raw, al(ISO 2631-5), D(ISO 2631-5) are available. RMS, Peak, Crest, peak-Peak, are also available in NVGate plug in.
 
Signal fitering including :
{| class="wikitable" style="margin: auto;"
|+style="caption-side:bottom;"|''Time-weighting filters''
|-
|style="height:30px; width:100px;"|<math>W_k</math>
|Time weighting for the Z axis for whole-body measurement (ISO 2651-1)
|-
|style="height:30px; width:100px;"|<math>W_d</math>
|Time weighting for the X and Y axis for whole-body measurement (ISO 2651-1)
|-
|style="height:30px; width:100px;"|<math>W_h</math>
|Time weighting for the hand-arms measurement in any direction (ISO 5349-1)
|-
|style="height:30px; width:100px;"|<math>W_f</math>
|Time weighting for motion sickness measurement in the vertical direction (ISO 2651-1)
|-
|style="height:30px; width:100px;"|<math>W_c</math>
|Time weighting for the X axis for whole-body measurement (ISO 2651-1)
|-
|style="height:30px; width:100px;"|<math>W_e</math>
|Time weighting for all rotational directions for whole-body measurement (ISO 2651-1)
|-
|style="height:30px; width:100px;"|<math>W_j</math>
|Time weighting for the Z axis for head comfort measurement (ISO 2651-1)
|}
 
 
The whole body vibration is applicable from vehicles and workplace machines through a supporting surface. For hand hamr vibrationon we need specific sensors wich are installed on adapters for holding them on a handle or between fingers


= Orbit display include on  FFT diag or ORD diag =
= Orbit display include on  FFT diag or ORD diag =

Navigation menu