* '''Keep test masses '''after test for example welding or drilling etc. | * '''Keep test masses '''after test for example welding or drilling etc. | ||
* '''Displace two masses per plane '''for machines with slidable balancing weights. | * '''Displace two masses per plane '''for machines with slidable balancing weights. | ||
An example is shown where test mass is to be removed. The test mass of 5 grams '''(4)''' </font>is set at position 8 (225°; radius 100 mm) '''(3)'''</font> | |||
The settings are saved automatically when closing the window. | The settings are saved automatically when closing the window. |