'''The analyzer is now ready for measurement.''' | '''The analyzer is now ready for measurement.''' | ||
The '''Rotor''' windaiw is automatically displayed. You can now prepare your test run or close this window to set it up later: | |||
Your settings are shown by a red point in the polar graph. | |||
There are three methods: | |||
* '''Remove test masses ''' : The test mass will be removed after test for example bolts etc. | |||
* '''Keep test masses ''' : The test mass cannot be removed after the test (for example for welding or drilling etc…) | |||
* '''Displace two masses per plane '''for machines with slidable balancing weights. | |||
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm). | |||
The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''</font>. | |||
[[Image:Bal_1_Test_Prep.png|framed|none]] | |||
Click on OK to come back on the measurment window.<br> | |||
To start the analyzer click '''(1)''' or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed. | To start the analyzer click '''(1)''' or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed. |