'''The analyzer is now ready for measurement.'''
'''The analyzer is now ready for measurement.'''
The '''Rotor''' windaiw is automatically displayed. You can now prepare your test run or close this window to set it up later:
Your settings are shown by a red point in the polar graph.
There are three methods:
* '''Remove test masses ''' : The test mass will be removed after test for example bolts etc.
* '''Keep test masses ''' : The test mass cannot be removed after the test (for example for welding or drilling etc…)
* '''Displace two masses per plane '''for machines with slidable balancing weights.
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).
The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''</font>.
[[Image:Bal_1_Test_Prep.png|framed|none]]
Click on OK to come back on the measurment window.<br>


To start the analyzer click '''(1)''' or <nowiki>[</nowiki>F2<nowiki>]</nowiki> and the Measurement is displayed.