8,877
edits
Line 1: | Line 1: | ||
=Single / Dual PLANE Balancing: User<nowiki>'</nowiki>s Manual= | =Single / Dual PLANE Balancing: User<nowiki>'</nowiki>s Manual= | ||
Line 79: | Line 77: | ||
'''Accelerometer''' | '''Accelerometer''' | ||
The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example in '''Sketch 1,''' the | The measurement direction of the accelerometer must be referred to the tach sensor position. This can be done by the "Angular correction" in the analyzer setup. In our example in '''Sketch 1,''' the '''angular correction''' is '''90°''' and the <font color="#339966">'''offset''' is -'''15 °'''. | ||
'''Tip''' | '''Tip''' | ||
Line 220: | Line 218: | ||
'''Step 1''' | '''Step 1''' | ||
'''(1) '''Click to open the explorer,''' (2)''' In the Explorer, '''(3)''' click to open a new sub directory | |||
'''(4)''' Rename the new sub directory to "Machine" and double click to change into the new subdirectory | |||
[[Image:Balancing_15.png|framed|none]] | [[Image:Balancing_15.png|framed|none]] | ||
Line 230: | Line 228: | ||
'''Step 2:''' | '''Step 2:''' | ||
'''(1)''' Sub directory Machine '''(2)''' Enter project name Engine A '''(3)''' Click to save the new project | |||
[[Image:Balancing_16.png|framed|none]] | [[Image:Balancing_16.png|framed|none]] | ||
Line 255: | Line 253: | ||
Choose what you need for your measurement, by clicking on '''A, B, C''' or '''D''' or use the following shortcuts: <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>A<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>B<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>C<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>D<nowiki>]</nowiki> | Choose what you need for your measurement, by clicking on '''A, B, C''' or '''D''' or use the following shortcuts: <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>A<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>B<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>C<nowiki>]</nowiki>, <nowiki>[</nowiki>Alt<nowiki>]</nowiki> <nowiki>+</nowiki> <nowiki>[</nowiki>D<nowiki>]</nowiki> | ||
The corresponding channels are activated. This is shown by a <font size = "5">'''''' | The corresponding channels are activated. This is shown by a <font size = "5">'''''' on the corresponding BNC connector in the Figure. | ||
Connect your transducers to the corresponding In-puts on your 3-SERIES analyzer. | Connect your transducers to the corresponding In-puts on your 3-SERIES analyzer. | ||
Line 263: | Line 261: | ||
<u>Example</u> | <u>Example</u> | ||
'''(1)''' Click on <u>C</u> for two Planes and two Sensors | |||
'''(2)''' Channel 1 is activated <font size = "4">'''''' | '''(2)''' Channel 1 is activated <font size = "4">'''''' | ||
'''(3)''' Ext. sync. 1 is activated | '''(3)''' Ext. sync. 1 is activated | ||
Line 431: | Line 429: | ||
Explanation of the graphs: | Explanation of the graphs: | ||
Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" | Polar graph: The blue point represents the magnitude and phase of the first order of averaged order spectrum (10 averages). Click "Initial run" '''(1)''' and save the initial measurement '''(2)'''. | ||
[[Image:Balancing_28.png|framed|none]] | [[Image:Balancing_28.png|framed|none]] | ||
Line 463: | Line 461: | ||
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm). | The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm). | ||
The settings are saved automatically when closing the window. To use these settings in another project, click on export | The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''. | ||
[[Image:Balancing_30.png|framed|none]] | [[Image:Balancing_30.png|framed|none]] | ||
Line 469: | Line 467: | ||
''Test mass positioning for one plane'' | ''Test mass positioning for one plane'' | ||
Click "Test run" | Click "Test run" '''(1)''' and save the measurement '''(2)'''. | ||
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''. | After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''. | ||
Line 492: | Line 490: | ||
<u>Example</u> | <u>Example</u> | ||
'''(1)''' Click to save the test run result | |||
'''(2)''' Click to start the calculation | '''(2)''' Click to start the calculation | ||
Line 515: | Line 513: | ||
{|border="2" cellspacing="0" cellpadding="4" width="100%" | {|border="2" cellspacing="0" cellpadding="4" width="100%" | ||
| | |'''(1)''' Select Init run <nowiki>+</nowiki> Test run<br>'''(2)''' Click OK to start the calculation<br>'''(3)''' Result - Unbalance and Phase | ||
|'''(4)''' Result - proposal mass and position<br>'''(5)''' Proposal position | |'''(4)''' Result - proposal mass and position<br>'''(5)''' Proposal position | ||
Line 534: | Line 532: | ||
{|border="2" cellspacing="0" cellpadding="4" width="100%" | {|border="2" cellspacing="0" cellpadding="4" width="100%" | ||
|<u>Example</u><br | |<u>Example</u><br>'''(1)''' Proposal mass and position<br>'''(2)''' Click to enter the mass 4,2 gram<br>'''(3)''' Initial Unbalance | ||
[[Image:Balancing_34.png|framed|none]] | [[Image:Balancing_34.png|framed|none]] | ||
<br>'''(4)''' Prognosis Unbalance | <br>'''(4)''' Prognosis Unbalance | ||
Line 558: | Line 556: | ||
<u>Example</u> | <u>Example</u> | ||
'''(1)''' Click to save the balancing run result | |||
'''(2)''' Click to start the calculation | '''(2)''' Click to start the calculation | ||
Line 587: | Line 585: | ||
===Measurements, display, storage=== | ===Measurements, display, storage=== | ||
'''(1)''' Click "Start" start or F2. Measurement is displayed. | |||
[[Image:Balancing_41.png|framed|none]] | [[Image:Balancing_41.png|framed|none]] | ||
Line 593: | Line 591: | ||
''Measurement Display'' | ''Measurement Display'' | ||
'''(1)''' Click "Average" when rotor is at stable speed (Stationary state). | |||
[[Image:Balancing_42.png|framed|none]] | [[Image:Balancing_42.png|framed|none]] | ||
Line 602: | Line 600: | ||
The figure shows the result of the initial run. | The figure shows the result of the initial run. | ||
'''(1)''' Click "Initial run" | |||
'''(2)''' Save your initial measurement | '''(2)''' Save your initial measurement | ||
Line 619: | Line 617: | ||
* Fix a test mass to the rotor. | * Fix a test mass to the rotor. | ||
* Mass, value and position must be set in the rotor geometry table. | * Mass, value and position must be set in the rotor geometry table. | ||
To do this click "Rotor" in the Measurement monitor | To do this click "Rotor" in the Measurement monitor '''(b)''' to open the rotor geometry window'''.''' | ||
Your settings are shown by a red point in the polar graph. | Your settings are shown by a red point in the polar graph. | ||
Line 628: | Line 626: | ||
* '''Keep test masses '''after test for example welding or drilling etc. | * '''Keep test masses '''after test for example welding or drilling etc. | ||
* '''Displace two masses per plane '''for machines with slidable balancing weights. | * '''Displace two masses per plane '''for machines with slidable balancing weights. | ||
It shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 3 ( | It shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 3 ('''2)''' (75°; radius 100 mm) '''(1)''' | ||
The settings are saved automatically when closing the window. | The settings are saved automatically when closing the window. | ||
Line 640: | Line 638: | ||
''Test run 1'' | ''Test run 1'' | ||
Click "Test run" | Click "Test run" '''(1)''' and save the measurement '''(2)'''. | ||
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''. | After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''. | ||
Line 665: | Line 663: | ||
* '''Keep test masses '''after test for example welding or drilling etc. | * '''Keep test masses '''after test for example welding or drilling etc. | ||
* '''Displace two masses per plane '''for machines with slidable balancing weights. | * '''Displace two masses per plane '''for machines with slidable balancing weights. | ||
'''A'''n example is shown where test mass is to be removed. The test mass of 4.2 grams | '''A'''n example is shown where test mass is to be removed. The test mass of 4.2 grams '''(3)''' is set at position 4 (105°; radius 100 mm) '''(4)''' | ||
The settings are saved automatically when closing the window. | The settings are saved automatically when closing the window. | ||
Line 673: | Line 671: | ||
''Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2'' | ''Test mass 2 positioning for two planes - Test run 2 - Test mass 2 - Plane 2'' | ||
Set the Run number to 2 | Set the Run number to 2 (1) and save the measurement (2). | ||
[[Image:Balancing_50.png|framed|none]] | [[Image:Balancing_50.png|framed|none]] | ||
Line 685: | Line 683: | ||
<u>Example</u> | <u>Example</u> | ||
'''(1)''' Results for Plane 1 and Plane 2 | |||
'''(2)''' Save the results | '''(2)''' Save the results | ||
Line 700: | Line 698: | ||
<u>Example</u> | <u>Example</u> | ||
'''(1)''' Select Init run <nowiki>+</nowiki> Test run | |||
'''(2)''' Click OK to start the calculation | '''(2)''' Click OK to start the calculation | ||
Line 720: | Line 718: | ||
<u>Example</u> | <u>Example</u> | ||
'''(1)''' Result - Unbalance 1 and Phase 1 | |||
'''(2)''' Result - Unbalance 2 and Phase 2 | '''(2)''' Result - Unbalance 2 and Phase 2 | ||
Line 739: | Line 737: | ||
The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis. | The effect of balancing weights can now be predicted by the mathematical calculations of the balancing prognosis. | ||
Set mass and position of the mass you want to use in column "Mounted Mass" | Set mass and position of the mass you want to use in column "Mounted Mass" (1), (2) | ||
Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph). | Click on "Prognosis" to get the calculation of the expected residual unbalance (green point in polar graph). |