writer
12
edits
m (→LiveView) |
AmberSmith (talk | contribs) |
||
Line 2: | Line 2: | ||
NVGo is the MODS monitoring software for android devices. This app is designed to: | NVGo is the MODS monitoring software for android devices. This app is designed to: | ||
* Manage ''Templates'' for OR10 front-end and record setup | * Manage ''Templates'' for OR10 front-end and record setup | ||
* Adjust the front-end and recorder settings | * Adjust the front-end and recorder settings | ||
* Continuously monitor the signals in different domains (level, time and spectral) | * Continuously monitor the signals in different domains (level, time and spectral) | ||
* Start & stop recording | * Start & stop recording | ||
* Add properties and comments to records | * Add properties and comments to records | ||
* Manage records in OR10 memory | * Manage records in OR10 memory | ||
===Installation=== | ===Installation=== | ||
1. Register on [http://www.myoros.com/ www.myOROS.com] | 1. Register on [http://www.myoros.com/ www.myOROS.com]. | ||
2. From the ''Software'' section select ''NVGo'' -<nowiki>></nowiki> ''Latest software'' | 2. From the ''Software'' section, select ''NVGo'' -<nowiki>></nowiki> ''Latest software''. | ||
3. Download the latest NVGo Android Package Kit (.APK) on your Tablet or smartphone. | 3. Download the latest NVGo Android Package Kit (.APK) on your Tablet or smartphone. | ||
4. On your Android device open | 4. On your Android device open the downloaded section and select the NVGo .apk file, then choose install. | ||
5. Authorize the installation of unknown sources for | 5. Authorize the installation of unknown sources for this one downlaod, as OROS does not use Google play store for its software broadcasts. | ||
===Connection to OR10=== | ===Connection to OR10=== | ||
Line 24: | Line 24: | ||
[[Image:MODS_46.png|framed|none]] | [[Image:MODS_46.png|framed|none]] | ||
2. Power on the OR10 hardware | 2. Power on the OR10 hardware. | ||
3. Wait for power-on until you get the main menu on the OR10 screen | 3. Wait for power-on to complete, until you get the main menu on the OR10 screen. | ||
4. Press "Wi-Fi" button on NVGo. The Android Wi-Fi menu is displayed | 4. Press the "Wi-Fi" button on NVGo. The Android Wi-Fi menu is displayed. | ||
[[Image:MODS_47.png|framed|none]] | [[Image:MODS_47.png|framed|none]] | ||
Line 34: | Line 34: | ||
5. Connect to the OR10. | 5. Connect to the OR10. | ||
6. Press Android back () button to return | 6. Press Android back () button to return to NVGo. | ||
[[Image:MODS_48.png|framed|none]] | [[Image:MODS_48.png|framed|none]] | ||
Line 40: | Line 40: | ||
Refresh the instrument list. When your OR10 appears showing "Ready" | Refresh the instrument list. When your OR10 appears showing "Ready", click on it to start NVGo with this instrument. | ||
---- | ---- | ||
Line 58: | Line 58: | ||
Displayed inputs are changed by swiping the graph up/down. It is also possible to select the displayed inputs by pressing the selected input from the left column. | Displayed inputs are changed by swiping the graph up/down. It is also possible to select the displayed inputs by pressing the selected input from the left column. | ||
FFT settings allows adjusting averaging and resolution. Y scale may be set to linear or log. This preference is saved in the Android device. | FFT settings allows for adjusting averaging and resolution. The | ||
Y scale may be set to linear or log. This preference is saved in the Android device. | |||
---- | ---- | ||
Line 67: | Line 68: | ||
[[Image:MODS_51.png|framed|none]] | [[Image:MODS_51.png|framed|none]] | ||
Displayed inputs are changed by swiping the graph up | Displayed inputs are changed by swiping the graph up or down. It is also possible to select the displayed inputs by pressing the selected input from the left column. | ||
Y scale is continuously adjusted to input ranges. When the 2 active inputs show the same units, both Y scales are identical. | Y scale is continuously adjusted to input ranges. When the 2 active inputs show the same units, both Y scales are identical. | ||
Line 80: | Line 81: | ||
Caution, the playback volume is dependent on the used headphone impedance. Signal amplitudes close to the range peak may generate high volume with low impedance headphone. Usage of very low impedance below 60 Ohms is not recommended. The stereo allocation of the played signals may be inverted by pressing the headphone button until the 2 background colors are inverted. | Caution, the playback volume is dependent on the used headphone impedance. Signal amplitudes close to the range peak may generate high volume with low impedance headphone. Usage of very low impedance below 60 Ohms is not recommended. The stereo allocation of the played signals may be inverted by pressing the headphone button until the 2 background colors are inverted. | ||
===Setting up OR10=== | ===Setting up the OR10=== | ||
==== | ====Loading a Template==== | ||
The ''Templates'' are generated and added to the OR10 memory with NVGate (see NVGate Template generation §). They are used in the same way | The ''Templates'' are generated and added to the OR10 memory with NVGate (see NVGate Template generation §). They are used in the same way NVGate ''Models'' is in order to setup the front-end with predefined settings. The ''Template ''properties and description will be saved in the ''Measurements ''made with it. | ||
Press the central (''Setup'') field of the top ribbon to open the ''Template'' selection screen. | Press the central (''Setup'') field of the top ribbon to open the ''Template'' selection screen. | ||
[[Image:MODS_54.png|framed|none]] | [[Image:MODS_54.png|framed|none]] | ||
====Adjust the Front- | ====Adjust the Front-End==== | ||
Input settings may be adjusted manually. Press the left (''Settings'') BNC button of the top ribbon to open the ''Front-End settings'' screen. | |||
[[Image:MODS_55.png|framed|none]] | [[Image:MODS_55.png|framed|none]] | ||
====Adjust the | ====Adjust the Sampling Frequency==== | ||
The sampling frequency is always displayed in the main screen. Simply select the desired sampling rate from the Top | The sampling frequency is always displayed in the main screen. Simply select the desired sampling rate from the Top Ribbon drop down menu. | ||
[[Image:MODS_56.png|framed|none]] | [[Image:MODS_56.png|framed|none]] | ||
Line 98: | Line 99: | ||
This menu is not available when the OR10 is recording. | This menu is not available when the OR10 is recording. | ||
====Adjust the | ====Adjust the Recorder==== | ||
The recorder mode and duration may be adjusted. | The recorder mode and duration may be adjusted. On the left (''in Settings''), press the recorder button on the Top Ribbon to open the ''Recorder Settings'' screen. This menu is not available when the OR10 is recording. | ||
[[Image:MODS_57.png|framed|none]] | [[Image:MODS_57.png|framed|none]] | ||
You can choose between fixed duration ''Start to Time'' and manually controlled ''Start to Stop'' for recorder modes.<br> | |||
[[Image:MODS_58.png|framed|none]] | [[Image:MODS_58.png|framed|none]] | ||
[[Image:MODS_59.png|framed|none]] | [[Image:MODS_59.png|framed|none]] | ||
For ''Start to | For ''Start to Time'', the duration should be updated by editing the field or using the <nowiki>+</nowiki>/- buttons. | ||
===Make a | ===Make a Recording=== | ||
====Start | ====Start Recording==== | ||
When the OR10 setup is done, the system is ready | When the OR10 setup is done, the system is ready to start acquiring and saving the input data. To start the recording, press the bottom left ''Run'' button or press the "REC" button on the OR10. | ||
[[Image:MODS_60.png|framed|none]] | [[Image:MODS_60.png|framed|none]] | ||
To stop the recording, | To stop the recording, press ''Stop ''on the bottom left or press the "REC" button on the OR10. In ''Start to Time'' mode, the recording will stop automatically when the duration time is reached. | ||
====Save & | ====Save & Inform Recorded Data==== | ||
When the record is finished, the save screen is shown. | When the record is finished, the save screen is shown. | ||
[[Image:MODS_61.png|framed|none]] | [[Image:MODS_61.png|framed|none]] | ||
Recordings are saved with the predefined base name of | Recordings are saved with the predefined base name of ''Template''. A combination of 3 numbers and a letter is added to manage the multi-acquisitions: | ||
* Letter is incremented while using the same ''Template'' for multiple acquisitions (called RUNs) | * Letter is incremented while using the same ''Template'' for multiple acquisitions (called RUNs) | ||
Line 130: | Line 131: | ||
In that way, each RUN of a measurement type will be called: ''BaseName_102A, BaseName_102B, BaseName_102C'', etc… | In that way, each RUN of a measurement type will be called: ''BaseName_102A, BaseName_102B, BaseName_102C'', etc… | ||
All the properties with contents are saved with the recorded data. Saved properties will be associated to the ''Measurement ''when records are imported | All the properties with contents are saved with the recorded data. Saved properties will be associated to the ''Measurement ''when records are imported into NVGate. | ||
====Check OR10 | ====Check OR10 Memory Content==== | ||
You may browse the OR10 recorded data from NVGo. Press on the Capacity field (DAQ) which is in the Top Ribbon on the right. | |||
[[Image:MODS_62.png|framed|none]] | [[Image:MODS_62.png|framed|none]] |