8,877
edits
Line 41: | Line 41: | ||
'''Considerations for post-processing''' : If the time signal is recorded on the PC or on the Mobi-Disk<sup>™</sup>, it is highly recommended to be in office mode (hardware not connected) in order to avoid low performances and malfunctions. | '''Considerations for post-processing''' : If the time signal is recorded on the PC or on the Mobi-Disk<sup>™</sup>, it is highly recommended to be in office mode (hardware not connected) in order to avoid low performances and malfunctions. | ||
==Controls== | ==Controls== | ||
Line 136: | Line 111: | ||
* '''Auto width''': this function adjusts the width of the ASB. | * '''Auto width''': this function adjusts the width of the ASB. | ||
==Plug-in analyzer status== | |||
An icon is displayed in the ASB when a plug-in is connected. For each plug-in the icon displays the analysis status (running, stopped, recording...). | An icon is displayed in the ASB when a plug-in is connected. For each plug-in the icon displays the analysis status (running, stopped, recording...). | ||
* '''Running '''[[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_30.png]]: the plug-in analyzer is processing the data acquisition. | * '''Running '''[[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_30.png]]: the plug-in analyzer is processing the data acquisition. | ||
Line 146: | Line 121: | ||
* '''Failure '''[[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_36.png]]: the plug-in analyzer has failed (the analyzer is no longer able to compute the data acquisition; a warning message will appear) | * '''Failure '''[[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_36.png]]: the plug-in analyzer has failed (the analyzer is no longer able to compute the data acquisition; a warning message will appear) | ||
==Copy/Paste setting between plug-ins== | |||
By right clicking on any settings of the ASB you can Copy values of settings, and then Paste it anywhere else. There is an automatic type matching, which allows pasting only value of the same settings (using the IDN number). | By right clicking on any settings of the ASB you can Copy values of settings, and then Paste it anywhere else. There is an automatic type matching, which allows pasting only value of the same settings (using the IDN number). | ||
Line 153: | Line 128: | ||
For example you can see the same signal in the time domain and in the spectral domain, with exactly the same settings (for instance resolution). In the following example, the FFT1 have been set in the <nowiki>’</nowiki>Spectral domain<nowiki>’</nowiki>, with a specific range and a resolution. For the FFT2, right click on FFT2 and paste the setting from FFT1, then you have just to change the domain from spectral to time in that case. | For example you can see the same signal in the time domain and in the spectral domain, with exactly the same settings (for instance resolution). In the following example, the FFT1 have been set in the <nowiki>’</nowiki>Spectral domain<nowiki>’</nowiki>, with a specific range and a resolution. For the FFT2, right click on FFT2 and paste the setting from FFT1, then you have just to change the domain from spectral to time in that case. | ||
You can compare the signal in, exactly, the same conditions. | You can compare the signal in, exactly, the same conditions. | ||
==ASB User preference== | |||
NVGate provides specialized modes that enable dedicated functionalities related to the application. By selecting specialized mode functionalities such as; | |||
By selecting specialized mode functionalities such as; | |||
* Availability of results | |||
* Settings | |||
* User preference, | |||
will be enabled. Unselecting specialized mode will mask these functionalities. There are 2 specialized modes: | |||
* '''Structural mode''': this mode is dedicated to the acquisition of modal data through hammer acquisition or signals provided by up to 6 shakers. The following topics are available when structural mode is active: | |||
* Visibility of FRF (H1, H2) and Coherence results in FFT plug-ins. | |||
* Visibility of time windows (force and response) in the ASB, and control panel. | |||
* Availability of the inputs node settings in the inputs properties (ASB, Control Panel and Ribbon) | |||
* | |||
[[Image:REF-MAN_VOL1_Analyzer_Settings_Browser_wiki_partA_03.png|framed|none]] | |||
Availability of accept/reject in the bottom right: | |||
* '''Rotating mode''': this mode is dedicated to rotating and reciprocating machines. The following topics are available when rotating mode is active: | |||
* FFT order extraction, constant band tracking or synchronous order. | |||
* Tachometer settings. | |||
* Plug-in analysis <nowiki>’</nowiki>Sync Order<nowiki>’</nowiki> will be unlocked. | |||
'''Note''': these specialized modes can be selected (by default) in the user<nowiki>’</nowiki>s preferences. |