Difference between revisions of "NVGate Ribbons: Measurement Tab"

Jump to navigation Jump to search
Line 21: Line 21:


Note: the trigger/start status of the plug-ins may block their process, waiting for an event.
Note: the trigger/start status of the plug-ins may block their process, waiting for an event.
[[Image:Reports_Tools_Ribbons_08.png|framed|none]]


Warning: Pressing the run button during an analysis lead to reset all current analyses, restarting all averages from 0. The analyzed data will be lost.
Warning: Pressing the run button during an analysis lead to reset all current analyses, restarting all averages from 0. The analyzed data will be lost.


*  
* [[Image:Reports_Tools_Ribbons_272.png]]Pause:  (Pause): Suspend or un-suspend the current analysis.
[[Image:Reports_Tools_Ribbons_272.png|framed|none]]
Pause:  (Pause): Suspend or un-suspend the current analysis.


Note: If the recorder is running, its starts / finishes a record.
Note: If the recorder is running, its starts / finishes a record.


*  
* [[Image:Reports_Tools_Ribbons_273.png]] Stop:  (CTRL<nowiki>+</nowiki>S) Stops all the current analyses and recording.
[[Image:Reports_Tools_Ribbons_273.png|framed|none]]
Stop:  (CTRL<nowiki>+</nowiki>S) Stops all the current analyses and recording.


After requesting a stop, the plug-ins finished their current block. When all the plug-ins has switched to'' Stopped'' the analyzer switch to the Stopped status
After requesting a stop, the plug-ins finished their current block. When all the plug-ins has switched to'' Stopped'' the analyzer switch to the Stopped status
Line 42: Line 36:
Note that another Run/Pause/Stop button is always available in the status bar (bottom left)
Note that another Run/Pause/Stop button is always available in the status bar (bottom left)


*  
* [[Image:Reports_Tools_Ribbons_274.png]]Arm:  (CTRL<nowiki>+</nowiki>SHIFT<nowiki>+</nowiki>R) Arm the recorder. Prepare the recorder to start immediately on the run. Arming process can lap a few seconds.
[[Image:Reports_Tools_Ribbons_274.png|framed|none]]
Arm:  (CTRL<nowiki>+</nowiki>SHIFT<nowiki>+</nowiki>R) Arm the recorder. Prepare the recorder to start immediately on the run. Arming process can lap a few seconds.


Note: modifying a setting of the analyzer will disable the arming. It is then necessary to re-arm it.
Note: modifying a setting of the analyzer will disable the arming. It is then necessary to re-arm it.
Line 50: Line 42:
If the recorder is not armed, it will take a few second to achieve the arming prior to effectively start recording the data.
If the recorder is not armed, it will take a few second to achieve the arming prior to effectively start recording the data.


* Note: the recoer can be armed from the ASB: (Recorder /Trigger/ Recorder) ''See Chapter 1 ASB - § Recorder/Trigger settings for details.''
* Note: the recorer can be armed from the ASB: (Recorder /Trigger/ Recorder).


*  
* [[Image:Reports_Tools_Ribbons_275.png]]Manual trigger:  (CTRL<nowiki>+</nowiki>T) generate a manual trigger event. This event is available for the event list and can be associated to the plug-in triggers (start/stop or trigger). See acquisition tab description.
[[Image:Reports_Tools_Ribbons_275.png|framed|none]]
Manual trigger:  (CTRL<nowiki>+</nowiki>T) generate a manual trigger event. This event is available for the event list and can be associated to the plug-in triggers (start/stop or trigger). See acquisition tab description.


Warning: While the manual trigger is not associated to a plug-in, it has no effect.
Warning: While the manual trigger is not associated to a plug-in, it has no effect.


*  
* [[Image:Reports_Tools_Ribbons_276.png]] Record status: Controls the recorder location and activity.
[[Image:Reports_Tools_Ribbons_276.png|framed|none]]
Record status: Controls the recorder location and activity.
* If the setting is set to Off, the icon is grayed  
* If the setting is set to Off, the icon is grayed  
[[Image:Reports_Tools_Ribbons_277.png|framed|none]]
[[Image:Reports_Tools_Ribbons_277.png|framed|none]]

Navigation menu