The XPod is a device that can be fixed on OR3X TW analyzer. Each XPod is associated to a block of 8 inputs.
The XPod is a device that can be fixed on OR3X TW analyzer. Each XPod is associated to a block of 8 inputs.
[[File:Xpod-plug.png|framed|none]]
In the connected mode, when and XPod is present each corresponding input can be routed to:
· The BNC input (Standard)
· The XPod connector
* '''Type''': For acquisition setup preparation, the XPod presence can be simulated in the office mode:
One XPod type selector is available for each XPod position. This setting will include each new Xpod type according to their availability on the OROS catalog.
[[Image:front_end_07.png|framed|none]]


===X-Pod Strain gauge Bridge===
===X-Pod Strain gauge Bridge===
OROS analyzers feature optional Wheatstone bridge conditioner.  The scope of this document is to provide the information for the bridge connections on the Xpod connectors.
[[XPod_Bridge_-_Strain_gauge|Read this page]]
[[File:xpod_strain.png|none]]
====Tutorial====
You can find here a dedicated process for using it
 
 
* '''Bridge max current''': Select the max excitation current for the corresponding active Bridge Xpod. Each bridge Xpod excitation current can be limited to 30 mA up to 4 V and 12 mA up to 10 V.
* '''Bridge voltage''': Select the excitation voltage for the corresponding active Bridge Xpod. From 0 to 10 V.
* '''Cold Compensation''':''' '''Enable or disable the internal cold junction compensation for the corresponding active Temperature Xpod. This setting enables the compensation of the connectors metal junction thermocouple voltage at the Xpod side. It uses the Xpod internal temperature measurement (2 locations/Xpod) to correct the measured temperatures.
The XPod Bridge conditioner extension module is for strain gauges, dynamic pressure, force and acceleration measurements.
 
*'''Type:''' bridge signal conditioning for strain gage. <br>
 
*'''Gauge type''': Full, Half or Quarter bridge mount. The completion resistors are included in the Xpod.<br>
 
*'''Resistance''': Bridge completion resistor: 120 or 350 Ohms for quarter bridge mount.<br>
 
*'''Gain''': Bridge gain: 10 or 100 depending on the required precision and range.<br>
 
*'''Max current''': the provided current can be limited to 30 mA up to 4 V and 12 mA up to 10 V.<br>
 
*'''Excitation voltage''': Each Xpod provides an excitation voltage from 0 to 10 V.<br>
 
*'''Offset Comp.''': Bridge offset comp: Can be used for manual balance of the bridge.<br>


===X-Pod: Temperature probe conditioner===
===X-Pod: Temperature probe conditioner===
[[File:Xpod_temp.png|Xpod_temp.png]]
[[NVGate_X-Pod:_Temperature_probe_conditioner|Read this page]]
 
This Xpod handles thermocouples and RTD transducers.
 
* '''PT100, PT1000 and J, K, T, N, E'''
* Integrated '''linearization'''
* Automatic '''cold junction compensation'''
* Standard fl at pin '''connectors'''
 
[[Image:front_end_08.png|framed|none]]