The XPod is a device that can be fixed on OR3X TW analyzer. Each XPod is associated to a block of 8 inputs. | The XPod is a device that can be fixed on OR3X TW analyzer. Each XPod is associated to a block of 8 inputs. | ||
[[File:Xpod-plug.png]] | |||
In the connected mode, when and XPod is present each corresponding input can be routed to: | In the connected mode, when and XPod is present each corresponding input can be routed to: | ||
Line 277: | Line 279: | ||
===X-Pod Strain gage Bridge=== | ===X-Pod Strain gage Bridge=== | ||
[[File:xpod_strain.png]] | |||
* '''Bridge max current''': Select the max excitation current for the corresponding active Bridge Xpod. Each bridge Xpod excitation current can be limited to 30 mA up to 4 V and 12 mA up to 10 V. | * '''Bridge max current''': Select the max excitation current for the corresponding active Bridge Xpod. Each bridge Xpod excitation current can be limited to 30 mA up to 4 V and 12 mA up to 10 V. | ||
Line 299: | Line 301: | ||
===X-Pod: Temperature probe conditioner=== | ===X-Pod: Temperature probe conditioner=== | ||
[[File:Xpod_temp.png|Xpod_temp.png]] | |||
This Xpod handles thermocouples and RTD transducers. | This Xpod handles thermocouples and RTD transducers. |