The hardware consists of an interface box which is adapted to the CAN-Bus impedance and a High speed serial cable (1 and 3 meters) connected to the new analyzer<nowiki>’</nowiki>s high speed serial port. When connected to a CAN-bus the parameter encoding has to be setup in the software allowing their collection by the hardware.
The hardware consists of an interface box which is adapted to the CAN-Bus impedance and a High speed serial cable (1 and 3 meters) connected to the new analyzer<nowiki>’</nowiki>s high speed serial port. When connected to a CAN-bus the parameter encoding has to be setup in the software allowing their collection by the hardware.
[[Image:Release_note_16.png|framed|none]]
[[Image:Release_note_16.png|framed|none]]


When connected to a CAN-bus the parameter encoding has to be setup in the software allowing their collection by the hardware.
When connected to a CAN-bus the parameter encoding has to be setup in the software allowing their collection by the hardware.


* '''CAN Mode: '''The Mode one defines the protocol to be used. Most of CAN bus uses 11 bits protocol.
* '''CAN Mode: '''The Mode one defines the protocol to be used. Most of CAN bus uses 11 bits protocol.
Line 169: Line 167:


[[Image:Release_note_17.png|framed|none]]
[[Image:Release_note_17.png|framed|none]]
<br>The Baud rate one defines the speed of the bus. 500 Mb/s is the most common baud rate for automotive application


Then each CAN parameter is declared in the CAN input list. One CAN inputs corresponds to one parameter from the CAN bus. The CAN inputs are enabled like the DC inputs.
Then each CAN parameter is declared in the CAN input list. One CAN inputs corresponds to one parameter from the CAN bus. The CAN inputs are enabled like the DC inputs.


[[Image:Release_note_18.png|framed|none]]
[[Image:Release_note_18.png|framed|none]]
Line 191: Line 185:


Up to 24 CAN parameters are available. Note that as the maximum recorded channels is 38, it is not possible to records all standards inputs (32 inputs <nowiki>+</nowiki> 4 aux. <nowiki>+</nowiki> 2 triggers) plus all CAN inputs (24 CAN parameters).
Up to 24 CAN parameters are available. Note that as the maximum recorded channels is 38, it is not possible to records all standards inputs (32 inputs <nowiki>+</nowiki> 4 aux. <nowiki>+</nowiki> 2 triggers) plus all CAN inputs (24 CAN parameters).
We are able to '''import CanBus .dbc file''' to automatically import the settings. [[NVGate_Tools:_CanBus_Import_.dbc|Read his page.]]


CAN parameters configurations are saved in a model, workbook or project and are easily recalled for further utilization.