Difference between revisions of "NVGate Ribbons overview"

Jump to navigation Jump to search
no edit summary
Line 1: Line 1:
===Interface description and Ribbon overview===
[[Image:Usersmanual_120.png|framed|none]]
====Vision====
The Vision interface gathers the analyzers functionalities in simple, clear and easy to identify tabs organized according to the main operations (First steps, measuring, results edition, configuration build-up, automation, general setup etc…).
Key features have been emphasized by the Vision interface, guiding the users to the best way using their OROS 3-Series analyzer.
=====Tab & groups=====
The new interface layer features 7 standard tabs (optional tab are also visibles). Each tab contains a set of groups which gathers settings, info and buttons about one topic (e.g. disk, FFT or transducers).
[[Image:Usersmanual_121.png|framed|none]]
=====Actions=====
The groups contain buttons, setting and check boxes of different types:
'''Buttons: ''' Left click on it leads to an action or opens a dialog box.
Examples:
[[Image:Usersmanual_122.png|framed|none]]
for auto scale or
[[Image:Usersmanual_123.png|framed|none]]
for inputs connection
'''Status buttons: ''' These buttons work like the standard ones but they can be activated or de-activated. They are used for changing a state. An activated button is slightly darkened.
Examples:
[[Image:Usersmanual_124.png|framed|none]]
that switches between '''on-line''' and '''post-analysis''' modes,<br> or''' '''
[[Image:Usersmanual_125.png|framed|none]]
''' '''for '''enabling the marker''' manipulations.
'''Settings: '''Provide a direct access to one of the ASB setting. Allow to continuously check the setup.
Examples:
[[Image:Usersmanual_126.png|framed|none]]
for a numerical setting,
'''
[[Image:Usersmanual_127.png|framed|none]]
'''for a '''Boolean''' (check box),
[[Image:Usersmanual_128.png|framed|none]]
for a selection in a list
[[Image:Usersmanual_11.png|framed|none]]
'''Multi-actions: ''' These buttons work as the standard ones but it is possible to select their action from a list. ''' '''When an action item is selected from the list, it becomes the default action of the button, the icon is changed.
Examples are: Marker, or User selection.
'''Status buttons: ''' These buttons change and show the status of the active element (windows, trace, etc..). Selecting one of the items in their list will apply this status to the active element. The status buttons change depending on the applied changes to the element (or change of element). It is useful to monitor and see immediately in what state is a 3D or the active user for example.
'''Note''': The buttons are highlighted when the mouse pointer pass over an active button.
=====FIle Menu=====
A unique "File" menu is available on upper left for input/output file operation. It allows loading/saving setups and provides access to the on-line help.
=====Status bar=====
At the bottom of the screen a fixed status bar maintains a continuous monitoring of the inputs and analysis:
[[Image:Usersmanual_129.png|framed|none]]
=====On line help on Vision ribbons=====
The content of the Vision™ ribbons are connected to the on-line help.
[[Image:Usersmanual_130.png|framed|none]]
In order to get help from one of the Vision elements, activate the help mode by clicking on the upper right question mark. The cursor switches to a pointer <nowiki>+</nowiki> question mark. Then click on the desired item. The corresponding page of the reference manual will be opened.
Note that the latest pdf reader software is supported with NVGate: Acrobat reader 32 or 64 bits and Acrobat and any other pdf reader. The ability to open the manual at the corresponding pages is supported by Adobe™ products only. OROS recommend using acrobat reader using the on-line help functionality.
=====Minimize ribbon and full screen=====
In order to gain space on the NVGate screen during acquisition and analysis the NVGate ribbon can be minimized. It operates like in the MS Office suite:
Use the upper right arrow to minimize or reset the ribbon size. When the ribbon is minimized the tab header remains visible. Their content is accessible by clicking on the corresponding tab header. The full screen function has been improved. It hides the application top bar as well as the windows bottom bar.
[[Image:Usersmanual_131.png|framed|none]]
=====Log window=====
[[Image:Usersmanual_132.png|framed|none]]
In the Home tab, tick/untick the Log window
[[Image:Usersmanual_133.png|framed|none]]
to show/hide the Log window (Analyzer settings, Warning and Macro Trace information).