| Line 308: |
Line 308: |
|
| |
|
| NVGate allows achieving angular sampled analysis avoiding the artefacts introduced by the direct angular sampling. | | NVGate allows achieving angular sampled analysis avoiding the artefacts introduced by the direct angular sampling. |
|
| |
|
| |
|
| |
| =====Limits=====
| |
| * The gap must be at least 1 tooth long, i.e. the gap interval must be longer than twice the normal interval. With a shorter gap (g = 0.6 tested), no setting gives a correct speed (spikes of 37 to 39 %).
| |
| * Near a whole number (g = 1.95, 2.0, 2.05), setting that whole number is correct on both sides; setting the lower whole number fails as soon as the gap exceeds it (g = 2.05 set to 1 → +1.8 %).
| |
| * In post-processing, when the ''Tach'' option of Signal Op. is used, check that the ''Missing teeth'' value of the created tachometer (''Tachometer > Ext. tach. 1'') is the same as the Tors one.
| |