Difference between revisions of "Balancing Manual"

Jump to navigation Jump to search
3 bytes added ,  15:25, 19 December 2023
no edit summary
Line 5: Line 5:
==Disable some rotor positions==
==Disable some rotor positions==


Rotor positions can be disabled in the correction prognosis: Indeed, there are multiple reasons in situ to not be able to add new correction masses at certain positions.
Rotor positions can be disabled in the correction prognosis.
Indeed, there are multiple reasons in situ to not be able to add new correction masses at certain positions.


[[File:disable.jpg]]
[[File:disable.jpg]]
Line 11: Line 12:
==Correction weight from a weight database==
==Correction weight from a weight database==


Calculation can take into account predefined weights for correction: First User has to enter a list of available weights so that recommended correction will take into account in the calculation.
Calculation can take into account predefined weights for correction.
First User has to enter a list of available weights so that recommended correction will take into account in the calculation.


[[File:weight_database.jpg]]
[[File:weight_database.jpg]]
Line 17: Line 19:
==Set max allowed weight for rotor position==
==Set max allowed weight for rotor position==


It is also possible to set a max allowed weight per position. Indeed, some rules are usually followed to ensure mechanical rotor integrity. The correction calculation will take into account this limitation.
It is also possible to set a max allowed weight per position.  
Indeed, some rules are usually followed to ensure mechanical rotor integrity.  
The correction calculation will take into account this limitation.


[[File:max_allowed_weight.jpg]]
[[File:max_allowed_weight.jpg]]
writer
75

edits

Navigation menu