9,040
edits
Line 51: | Line 51: | ||
(****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38. | (****) Stand-alone measurements are possible only with SSD-equipped models OR10 / TW OR35 / TW OR36 / TW OR38. | ||
=Introducing the hardware= | ==Introducing the hardware== | ||
==Small and lightweight== | ===Small and lightweight=== | ||
[[File:model.jpg|200px|right]] | [[File:model.jpg|200px|right]] | ||
Line 72: | Line 72: | ||
<br> | <br> | ||
==Ethernet LAN interface== | ===Ethernet LAN interface=== | ||
[[image:laninterface.PNG|right]] | [[image:laninterface.PNG|right]] | ||
Achieves high-speed communication with a PC through an ethernet LAN interface | Achieves high-speed communication with a PC through an ethernet LAN interface | ||
Line 92: | Line 92: | ||
TW OR36 / TW OR38 can be operated by battery for 2 hours. | TW OR36 / TW OR38 can be operated by battery for 2 hours. | ||
==External battery== | ===External battery=== | ||
[[File:external battery.PNG|200px|right]] | [[File:external battery.PNG|200px|right]] | ||
Line 109: | Line 109: | ||
<br> | <br> | ||
==Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers== | ===Synchronous Measurement Of Up To 1000 Channels is Possible by Combining Multiple Analyzers=== | ||
(TW OR35 / TW OR36 / TW OR38 only) | (TW OR35 / TW OR36 / TW OR38 only) | ||
Line 116: | Line 116: | ||
[[File:teamworkanalyzer.png|700px]] | [[File:teamworkanalyzer.png|700px]] | ||
== Measure From Sound / Vibration and Strain Gauge / Temperature == | === Measure From Sound / Vibration and Strain Gauge / Temperature === | ||
(OR35 / TW OR36 / TW OR38 only) | (OR35 / TW OR36 / TW OR38 only) | ||
[[File:Usersmanual_32.jpg|200px|right]] | [[File:Usersmanual_32.jpg|200px|right]] | ||
Line 127: | Line 127: | ||
<br> | <br> | ||
==CAN-bus Module Available == | ===CAN-bus Module Available === | ||
[[File:Can_Bus.jpg|150px|right]] | [[File:Can_Bus.jpg|150px|right]] | ||
(OR10/ TW OR35 / TW OR36 / TW OR38 only) | (OR10/ TW OR35 / TW OR36 / TW OR38 only) | ||
Line 135: | Line 135: | ||
<br> | <br> | ||
==Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode == | ===Recording is possible without the use of a PC by using the FFT analyzer in stand alone mode === | ||
(OR35 / TW OR36 / TW OR38 only) | (OR35 / TW OR36 / TW OR38 only) | ||
Line 154: | Line 154: | ||
<br> | <br> | ||
=Software Introduction= | ==Software Introduction== | ||
*Easy-to-use interface | *Easy-to-use interface | ||
Line 160: | Line 160: | ||
*One-click report creation function | *One-click report creation function | ||
==Start the Measurement Quickly and Easily== | ===Start the Measurement Quickly and Easily=== | ||
Line 171: | Line 171: | ||
[[File:home3.PNG|800px]] | [[File:home3.PNG|800px]] | ||
==One-click Setting Function== | ===One-click Setting Function=== | ||
With the OR3X series multi-job FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below. | With the OR3X series multi-job FFT analyzer, you can display related measurement condition settings by double-clicking on the measurement screen. For example, if you double-click on the FFT analysis screen, the dialog for setting the measurement conditions for FFT analysis will be displayed on the screen as shown below. | ||
Line 177: | Line 177: | ||
[[File:FFT_analyzer_spectrum.png|500px]] | [[File:FFT_analyzer_spectrum.png|500px]] | ||
==Control Panel== | ===Control Panel=== | ||
In addition, the OR3X series multi-job FFT analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the [[NVGate_Control_Panel|control panel]]. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel. | In addition, the OR3X series multi-job FFT analyzer is equipped with a control panel function that allows users to save frequently used measurement settings for quick access. By using this function, all settings can be changed on the [[NVGate_Control_Panel|control panel]]. For example, the following is the setting screen for a hammer test. By saving the input settings, threshold settings, and FFT analysis settings to the control panel as shown below, it is possible to make all the necessary settings quickly by only using the control panel. | ||
[[File:control pannel_test.png|700px]] | [[File:control pannel_test.png|700px]] | ||
==Various filters can be applied to recorded signals & FFT analysis results== | ===Various filters can be applied to recorded signals & FFT analysis results=== | ||
Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a [[NVGate_Filter_Builder|filter]], it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components. | Four types of filters: Low-pass filter, high-pass filter, band-bus filter, and band-stop filter, can be applied to the results of recorded signal and FFT analysis. By using a [[NVGate_Filter_Builder|filter]], it is possible to remove abnormal noise components from the recorded signal and perform processing such as reproducing the extracted abnormal noise components. | ||
[[File:filter_fft.png|600px]] | [[File:filter_fft.png|600px]] | ||
==Extract arbitrary order components from the color spectrum graph in real time== | ===Extract arbitrary order components from the color spectrum graph in real time=== | ||
Any order component can be extracted in real time from the color spectrum graph. | Any order component can be extracted in real time from the color spectrum graph. | ||
Line 222: | Line 222: | ||
[[File:octave waterfall.jpg]] | [[File:octave waterfall.jpg]] | ||
==Easy operation <Graph layout selection button>== | ===Easy operation <Graph layout selection button>=== | ||
Line 239: | Line 239: | ||
[[File:drag_drop_report.jpg]] | [[File:drag_drop_report.jpg]] | ||
==One-click report creation function== | ===One-click report creation function=== | ||
Line 250: | Line 250: | ||
[[File:report-customize.jpg|500px]] | [[File:report-customize.jpg|500px]] | ||
==Measurement data search function== | ===Measurement data search function=== | ||
[[File:pc cloud.PNG|right]] | [[File:pc cloud.PNG|right]] | ||
Various information (meta-data) can be added when saving measurement data. | Various information (meta-data) can be added when saving measurement data. | ||
Line 264: | Line 264: | ||
[[File:filter_project.PNG|550px]] | [[File:filter_project.PNG|550px]] | ||
==Fail judgment function as standard== | ===Fail judgment function as standard=== | ||
The [https://youtu.be/kx2HbcvfG_w pass / fail feature] of NVGate can be performed automatically after setting the desired bounds. | The [https://youtu.be/kx2HbcvfG_w pass / fail feature] of NVGate can be performed automatically after setting the desired bounds. | ||
Line 271: | Line 271: | ||
[[File:fail_test.JPG]] | [[File:fail_test.JPG]] | ||
==Automate post-analysis processing== | ===Automate post-analysis processing=== | ||
The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours. | The same processing can be continuously performed for record files measured multiple times. By using this function, it is possible to automate the generation of reports, and it is possible to generate the same number of post-analysis results and EXCEL-based reports as record files with one click. Processing that used to take more than a week can now be done in a few hours. | ||
Line 278: | Line 278: | ||
[[File:BPP2.jpg]] | [[File:BPP2.jpg]] | ||
==specification== | ===specification=== | ||
===Main specifications=== | ====Main specifications==== | ||
{| class=wikitable style="width:100%;" style="text-align:center;" | {| class=wikitable style="width:100%;" style="text-align:center;" | ||
Line 623: | Line 623: | ||
|}<br> | |}<br> | ||
===PC requirement=== | ====PC requirement==== | ||
Line 651: | Line 651: | ||
<br> | <br> | ||
=Function= | ==Function== | ||
Line 693: | Line 693: | ||
==Catalog download== | ===Catalog download=== | ||
[[File:download_brochure.jpg|left|250px]] | [[File:download_brochure.jpg|left|250px]] | ||
<br> | <br> | ||
Line 713: | Line 713: | ||
<br> | <br> | ||
==Applications/ Case study== | ===Applications/ Case study=== | ||
Line 822: | Line 822: | ||
[[File:reference.PNG|800px]] | [[File:reference.PNG|800px]] | ||
==Full technical support== | ===Full technical support=== | ||
Line 865: | Line 865: | ||
* Privileged access to extended services at a preferential rate: urgent loan within 1 day. | * Privileged access to extended services at a preferential rate: urgent loan within 1 day. | ||
==Video content == | ===Video content === | ||
'''Video content''' | '''Video content''' | ||