RT60 Calculator

From OROS Wiki
Revision as of 12:12, 28 November 2023 by Lmagimel (talk | contribs) (→‎Tips)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Reverberation in acoustics is the persistence of sound after a sound is produced. Reverberation, or reverb, is created when a sound or a signal is reflected causing a large number of reflections to build up and then decay as the sound is absorbed by the surfaces of objects in the space – which could include furniture, people, and air.

Definition: RT60 means '" Reverberation time - 60 dB". In other words, it means "how long a sound needs to decrease to 60 dB from it is initial energy level".

RT60 Measurement is used to define the Reverberation Time of a room in order to qualify this one.


RT60 05.png


Principle

The principle is to measure the RT60 for each third octave frequency band. Then, all these bands are combined to determine a global reverberation time.

Configuration

According to this method, the following plug-ins of NVGate are used:

  • OCT plug-in: to have the energy level by frequency band
  • Waterfall plug-in: to analyze the OCT profile
  • Noise generator: you can use an OROS OR3X analyzer to generate a noise

The corresponding NVGate project is already done. You can find it in the folder "RT60 NVGate Project". An example is also available below.

Notes: This program is working with NVGate V11.00 and later.

Calculation

After the measurement, import the data into the excel sheet. This document combines each frequency band and automatically calculates the reverberation time.

Please find the mentioned excel sheet in the folder "OROS RT60 Calculator". A tutorial is also available below.


Package

Download

Please contact your local distributor for access to the RT60 package.

Schedule a demo Get a quotation Contact support

Package composition

  • NVGate project folder
  • NVGate project
  • OROS Calculator Folder
  • RT60 Calculator.xlsm

RT60 Measurement

How to use RT60 NVGate model

Video Full tutorial

Note : The configuration project create on the video( step 1 to 7) is directly on the package, do not need to rebuild it.

Import the NVGate model into NVGate and perform the measurement

1- Copy the entire folder "RT60 third octave" and paste it into your NVGate model database. By default, the NVGate model database is located in: "C:\OROS\NVGate data\Workbook Library\User".

2- Create a new project in NVGate.

Project rt.png


3- Then, select the "RT60 Model" in the next window and click on "load".

Model rt60.png

4- Adjust the threshold of the EDGE 1. This event should start the waterfall.

5- Your measurement is ready; just start the measurement and stop your sound source just after.

6- Your measurement is saved and located in the project manager. There, right click on the result of your measurement and select export.

Project export.png

7- Finally, export your result in a .txt format.

On user export preference, use : "generate one file per result"

Export RT60.png

8- open the "OROS RT60 Calculator.xlsm".

How to use the OROS RT60 Calculator

Import file

1) In the tab "pos 1" of the Excel file "OROS RT60 Calculator", click on the "Import data position 1" button.

RT60 06.png

2) Then, select the .txt file to import.

3) Import the data of the other positions (using the same procedure).

4) In the "average level" tab, the average level of all the imported positions is automatically calculated. It is possible to deactivate a position in the settings tab:

RT60 07.png

In this example, the average level – and RT60 - will be calculated for positions 1, 2 and 3.

5) In the "overview" tab, you can have a look at the decay curve of each third octave band and check the regression line.

RT60 08.png

Part of the "overview" tab

6) If needed, it is possible to change the calculation mode (T20 / T30 / Manual) to see which one better fits the curve. For that, go to the tab corresponding to the third octave band frequency.

RT60 09.png

7) The report includes the RT60 values and the calculation mode (T20 / T30 / Manual ("m")) for each third octave band, a graph and the global RT60 value. You can change the frequency band for the global RT60 computation (from… to…).

RT60 10.png

Tips

1) In the settings tab, you can change the calculation mode for all third octave bands:

RT60 11.png

2) In the settings tab, you can choose the bounds of the graphs and click on "set" to change automatically the axis of all graphs.

RT60 12.png

3) To not display the 50, 63 and 80 Hz values in the report, adjust the following fields in the settings tab:

RT60 13.png

4) if any issue using the excel file "impulsive source" use this one "RT60 calculator impulsive source_corr" from november 2023


Schedule a demo Get a quotation Contact support