Difference between revisions of "NVGate Ribbons: Acquisition"

Jump to navigation Jump to search
Line 147: Line 147:


==Events group==
==Events group==
This group manages the events and corresponding triggers. It allows selecting the event type (source, setup) and associates it with the plug-in analyzers triggers.
[[File:Acquisition_events_tab_2022.PNG|200px]]
[[File:Acquisition_events_tab_2022.PNG|200px]]


{|border="0" cellspacing="0" cellpadding="4" width="100%" align="center"
{|border="0" cellspacing="0" cellpadding="4" width="100%" align="center"
|-
|-valign="top"
|[[File:Events_associate_to.PNG|30px]]
|[[File:Events_associate_to.PNG|30px]]
| '''Associate to''':  
| '''Associate to''':  


|-
|-valign="top"
|[[File:Event_edge_2022.PNG|30px]]
|[[File:Event_edge_2022.PNG|30px]]
| '''Edge''': Enables to copy or move Projects / Measurements / Models from the current Projects database to a specified target.
| '''Edge''': Detect when the signal from an input or a recorded track crosses a threshold. This module is used with the analog inputs (tach pulse or hammer impact). This trigger can be applied to any plug-in analyzer including Waterfall and Recorder.


|-
|-valign="top"
|[[File:Event_level_2022.PNG|30px]]
|[[File:Event_level_2022.PNG|30px]]
| '''Level''':  
| '''Level''': Detect when a signal is below or above a level This module is used with DC inputs (optional) and/or associated with the TDA or Monitor module. This event can be applied to any plug-in analyzer including Waterfall and Recorder.


|-
|-valign="top"
|[[File:event_periodic_2022.PNG|30px]]
|[[File:event_periodic_2022.PNG|30px]]
| '''Periodic''':  
| '''Periodic''': Used to trigger a plug-in by periodic step. This event can be applied to any plug-in analyzer including Waterfall and Recorder.


|-
|-valign="top"
|[[File:Event_RPM_2022.PNG|30px]]
|[[File:Event_RPM_2022.PNG|30px]]
| '''RPM''':  
| '''RPM''': Detect when a tachometer is below or above a specified angular speed. This module is associated with the Tachometer module. You need to first activate it on Tachometer plug in. This trigger can be applied to any plug-in analyzer including Waterfall and Recorder.


|-
|-valign="top"
|[[File:Event_delta_RPM_2022.PNG|30px]]
|[[File:Event_delta_RPM_2022.PNG|30px]]
| '''Delta RPM''':  
| '''Delta RPM''': Same as RPM but generates an event at each step. This module is associated with the Tachometer module. You need first to activate it on Tachometer plug in. It is used to trigger a plug-in by step. This trigger can be applied to any plug-in analyzer including Waterfall and Recorder.


|-
|-valign="top"
|[[File:Event_combined_2022.PNG|30px]]
|[[File:Event_combined_2022.PNG|30px]]
| '''Combined''':  
| '''Combined''': Generate an event which is the result of a combination of 2 events. Possible combinations are: OR, AND and AFTER.


|}<br clear="all">
|}<br clear="all">
Read [[NVGate_Event_definition|event definition]] page for details.