The sequencer is used to import/export/load/view an Excel® file that contains a series of steps. These steps are executed one by one. The sequencer is generally used to operate the Roving hammer impact for modal acquisition, for example.
The sequencer is used to import/export/load/view an Excel® file that contains a series of steps. These steps are executed one by one. The sequencer is generally used to operate the Roving hammer impact for modal acquisition, for example.
[[Image:Reports_Tools_Ribbons_123.png|framed|right]]
 
===Tutorial===
===Tutorial===


Line 33: Line 33:


==Sequencer==
==Sequencer==
=====Manage=====
[[Image:Reports_Tools_Ribbons_123.png]]
===Manage===
[[Image:Reports_Tools_Ribbons_124.png]] Opens the Sequence manager and displays the sequences list.
[[Image:Reports_Tools_Ribbons_124.png]] Opens the Sequence manager and displays the sequences list.


[[Image:Reports_Tools_Ribbons_125.png|framed|none]]
[[Image:Reports_Tools_Ribbons_125.png|framed|none]]


* Import: Imports a sequence from an Excel® file, to create a sequence in NVGate format. Sequences in NVGate format are stored in the "Sequence" directory.
* '''Import''': Imports a sequence from an Excel® file, to create a sequence in NVGate format. Sequences in NVGate format are stored in the "Sequence" directory.
Names of sequences in NVGate format are displayed by the sequence manager.<br>See Source format for more information about sequences in Excel®.
Names of sequences in NVGate format are displayed by the sequence manager.<br>See Source format for more information about sequences in Excel®.


* Export: Exports selected sequence (in NVGate format) to Excel®.
* '''Export''': Exports selected sequence (in NVGate format) to Excel®.
* Load: Loads selected sequence. Only the loaded sequence can be executed or opened in the sequence viewer to perform a modal analysis.
* '''Load''': Loads selected sequence. Only the loaded sequence can be executed or opened in the sequence viewer to perform a modal analysis.
* View: Opens the selected sequence in the Sequence viewer. Only the loaded sequence can be opened in the viewer.  
* '''View''': Opens the selected sequence in the Sequence viewer. Only the loaded sequence can be opened in the viewer.  


A Sequence is a set of acquisitions. Each acquisition is a set of setting modifications, and it is associated to a measurement. When a measurement is performed, the acquisition associated with it, is called the current acquisition and is designated by the execution pointer (yellow arrow to the left of the sequence tree). At the end of each measurement, next acquisition becomes current and is executed to prepare the next measurement. When an acquisition is executed, all settings assigned to it are applied.
A Sequence is a set of acquisitions. Each acquisition is a set of setting modifications, and it is associated to a measurement. When a measurement is performed, the acquisition associated with it, is called the current acquisition and is designated by the execution pointer (yellow arrow to the left of the sequence tree). At the end of each measurement, next acquisition becomes current and is executed to prepare the next measurement. When an acquisition is executed, all settings assigned to it are applied.


* Run/Pause
[[Image:Reports_Tools_Ribbons_126.jpg]]: When the sequence is not running, it is launched from the current acquisition. The current acquisition is executed to prepare the measurement.


Note: The Pause button operates at the inverse of the enable button in the sequence group ribbon.
===Sequence viewer===
 
[[Image:Reports_Tools_Ribbons_126.jpg]] '''Run/Pause''': When the sequence is not running, it is launched from the current acquisition. The current acquisition is executed to prepare the measurement.
 
''Note: The Pause button operates at the inverse of the enable button in the sequence group ribbon.''


* Reset
[[Image:Reports_Tools_Ribbons_127.jpg]] '''Reset''': Sets the execution pointer (which designates the current acquisition) to the first acquisition of the sequence.
[[Image:Reports_Tools_Ribbons_127.jpg]]: Sets the execution pointer (which designates the current acquisition) to the first acquisition of the sequence.


Note: the reset button operates like the reset button in the sequence group ribbon
Note: the reset button operates like the reset button in the sequence group ribbon


 
[[Image:Reports_Tools_Ribbons_128.jpg]] '''Back to previous''': The acquisition preceding the current acquisition becomes current and is executed.
* Back to previous
[[Image:Reports_Tools_Ribbons_128.jpg]]: The acquisition preceding the current acquisition becomes current and is executed.
Disabled if sequence is running.
Disabled if sequence is running.


* Run next
[[Image:Reports_Tools_Ribbons_129.jpg]] '''Run next''': The acquisition following the current acquisition becomes current and is executed. Disabled if the sequence is running.
[[Image:Reports_Tools_Ribbons_129.jpg]] : The acquisition following the current acquisition becomes current and is executed.
Disabled if the sequence is running.


Note: Next and previous button operates like the sequence browser arrows in the sequence group ribbon
''Note: Next and previous button operates like the sequence browser arrows in the sequence group ribbon.''


* Jump to: Accessible by right-clicking on the acquisition. This acquisition becomes current.
* '''Jump to''': Accessible by right-clicking on the acquisition. This acquisition becomes current.
* Delete: Deletes the selected acquisition.
* '''Delete''': Deletes the selected acquisition.
* Properties: Edits sequence properties.  
* '''Properties''': Edits sequence properties.  


[[Image:Reports_Tools_Ribbons_130.png]]
[[Image:Reports_Tools_Ribbons_130.png]]
Line 76: Line 74:
When "Run after setup" is checked, a new measurement is launched automatically after the current acquisition is executed.
When "Run after setup" is checked, a new measurement is launched automatically after the current acquisition is executed.


======Source format======
===Source format===
"Roving hammer test" sequence in Excel®.