= How much does this body shake? = | = How much does this body shake? = | ||
The OROS Body Vibration tool allows you to evaluate the effect of vibration on the human body according to standards ISO | The OROS Body Vibration tool allows you to evaluate the effect of vibration on the human body according to standards ISO 2631 and ISO 5349. These standards define measurement practice and vibration signal analysis to evaluate the effect on health and comfort of environmental and equipment vibrations on the Human body.<br> | ||
The ISO | The ISO 2631 describes the effect on health and comfort of vibration on the whole-body in transportation system, and the ISO 5349 the effect on health of vibration on hands and arms when manipulating machine-tools or vibrating objects.<br> | ||
<br> | <br> | ||
This is a post analysis toolkit, operating after the recording of the signal. It will calculate time-weighted signal of acceleration and specific indicators both defined in the standards.<br> | This is a post analysis toolkit, operating after the recording of the signal. It will calculate time-weighted signal of acceleration and specific indicators both defined in the standards.<br> | ||
Line 359: | Line 359: | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_k</math> | |style="height:30px; width:100px;"|<math>W_k</math> | ||
|Time weighting for the Z axis for whole-body measurement (ISO | |Time weighting for the Z axis for whole-body measurement (ISO 2631-1) | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_d</math> | |style="height:30px; width:100px;"|<math>W_d</math> | ||
|Time weighting for the X and Y axis for whole-body measurement (ISO | |Time weighting for the X and Y axis for whole-body measurement (ISO 2631-1) | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_h</math> | |style="height:30px; width:100px;"|<math>W_h</math> | ||
Line 368: | Line 368: | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_f</math> | |style="height:30px; width:100px;"|<math>W_f</math> | ||
|Time weighting for motion sickness measurement in the vertical direction (ISO | |Time weighting for motion sickness measurement in the vertical direction (ISO 2631-1) | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_c</math> | |style="height:30px; width:100px;"|<math>W_c</math> | ||
|Time weighting for the X axis for whole-body measurement (ISO | |Time weighting for the X axis for whole-body measurement (ISO 2631-1) | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_e</math> | |style="height:30px; width:100px;"|<math>W_e</math> | ||
|Time weighting for all rotational directions for whole-body measurement (ISO | |Time weighting for all rotational directions for whole-body measurement (ISO 2631-1) | ||
|- | |- | ||
|style="height:30px; width:100px;"|<math>W_j</math> | |style="height:30px; width:100px;"|<math>W_j</math> | ||
|Time weighting for the Z axis for head comfort measurement (ISO | |Time weighting for the Z axis for head comfort measurement (ISO 2631-1) | ||
|} | |} | ||