Difference between revisions of "NVGate 2021: Release note"

Jump to navigation Jump to search
Line 42: Line 42:
For the band pass and band stop filters, the low cut-off frequency ''f''<sub>low</sub> and the high cut-off frequency ''f''<sub>high</sub> need to meet the following conditions in the Office mode:
For the band pass and band stop filters, the low cut-off frequency ''f''<sub>low</sub> and the high cut-off frequency ''f''<sub>high</sub> need to meet the following conditions in the Office mode:


* 0.0001 * '''FR''' ≤ ''f''<sub>low</sub> 0.9996 * '''FR'''
* ''f''<sub>low</sub> 0.0001 * '''FR'''


* ''f''<sub>high</sub> ≤ '''FR'''
* ''f''<sub>high</sub> ≤ '''FR'''
Line 50: Line 50:
And in the Connected mode, the conditions are as below:
And in the Connected mode, the conditions are as below:


* 0.0005 * '''FR''' ≤ ''f''<sub>low</sub> 0.999325 * '''FR'''
* ''f''<sub>low</sub> 0.0005 * '''FR'''


* ''f''<sub>high</sub> ≤ '''FR'''
* ''f''<sub>high</sub> ≤ '''FR'''


* 0.000675 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR'''
* 0.000675 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR'''
In the previous version of NVGate, the conditions on the cut-off frequencies are:
* ''f''<sub>low</sub> ≥ 0.055 * '''FR'''
* ''f''<sub>high</sub> ≤ '''FR'''
* 0.0075 * '''FR''' ≤ ''f''<sub>high</sub> - ''f''<sub>low</sub> ≤ 0.99 * '''FR'''