Line 32: Line 32:
For the band pass and band stop filters, the filter order is 2*N, and N can be selected from 1 to 30 in Office mode, and between 1 to 10 in Connected mode now. In the previous NVGate version, the maximum value of N is 5.
For the band pass and band stop filters, the filter order is 2*N, and N can be selected from 1 to 30 in Office mode, and between 1 to 10 in Connected mode now. In the previous NVGate version, the maximum value of N is 5.


==No more limitation on the cut-off frequency==
==Significantly relaxed constraints on the cut-off frequency==
 
To guarantee the stability of the filter, there are certain constraints on the value of the cut-off frequency. Compared with previous version of NVGate, such constraints are relaxed significantly now.


[[File:filter_cut_off.png|600px]]
[[File:filter_cut_off.png|600px]]


===High pass and low pass===
For the high pass and low pass filters, the maximum value of the cut-off frequency is the input frequency range '''FR'''. The minimum value is '''FR''' / 50000 in Office mode, and '''FR''' / 40000 in Connected mode. In previous version of NVGate, the minimum value is '''FR''' / 40 for the low pass filter, and '''FR''' / 400 for the high pass filter.
===Band pass and band stop===
 
For the band pass and band stop filters,


==Improved precision==
==Improved precision==