Difference between revisions of "Balancing single/dual plane"

Jump to navigation Jump to search
Line 399: Line 399:


* Fix a test mass to the rotor.
* Fix a test mass to the rotor.
* Mass, value and position must be set in the rotor geometry table.
* Mass, value and position must be as set in the rotor geometry table.
To do this, click "Rotor" in the Measurement monitor to open the rotor geometry window'''.'''
To see the position and mass, click "Rotor" in the Measurement monitor to open the rotor geometry window'''.'''


Your settings are shown by a red point in the polar graph.
Your settings are shown by a red point in the polar graph. If you haven't set the test mass previously, you can do it now.


There are three methods:
Click on OK to go back in the Measurement window. Click "Test run" '''(1)''' </font>and save the measurement '''(2)'''</font>.
 
* '''Remove test masses '''after test for example bolts etc.
* '''Keep test masses '''after the test (for example for welding or drilling etc…)
* '''Displace two masses per plane '''for machines with slidable balancing weights.
The figure below shows an example where test mass is to be removed. The test mass of 4.2 grams is set at position 4 (105°; radius 100 mm).
 
The settings are saved automatically when closing the window. To use these settings in another project, click on export '''(1)''' </font>and save it in the sub directory of the other project. Proper settings can be loaded from another project '''(2)'''</font>.
 
[[Image:Bal_1_Test_Prep.png|framed|none]]
 
''Test mass positioning for one plane''
 
Click "Test run" '''(1)''' </font>and save the measurement '''(2)'''</font>.


After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.
After every test run, don<nowiki>'</nowiki>t forget to remove the test mass '''(3)'''.