8,877
edits
Line 7: | Line 7: | ||
Note: Clicking on the bottom right icon ([[Image:Reports_Tools_Ribbons_379.png]]) opens the monitor plug-in properties dialog allowing a full access to all the settings. | Note: Clicking on the bottom right icon ([[Image:Reports_Tools_Ribbons_379.png]]) opens the monitor plug-in properties dialog allowing a full access to all the settings. | ||
==Monitor== | |||
The Monitor input can be connected and hot swapped independently of any plug-in analysis. It is used to monitor one or several signals. | The Monitor input can be connected and hot swapped independently of any plug-in analysis. It is used to monitor one or several signals. | ||
[[Image:Waterfall_monitor_01.png|framed|none]] | [[Image:Waterfall_monitor_01.png|framed|none]] | ||
==Available results== | |||
* '''Triggered block''': This displays the time domain signal''.'' | * '''Triggered block''': This displays the time domain signal''.'' | ||
Line 19: | Line 19: | ||
* '''DC, Max, Min, RMS, Kurtosis''' on a specified band | * '''DC, Max, Min, RMS, Kurtosis''' on a specified band | ||
===Channel=== | |||
* [[Image:Reports_Tools_Ribbons_380.png]]'''Inputs:''' Opens the channels sources selection. Allows choosing which input or track is monitored. Up to 4 ch at a time. The channel sources can be swapped at any time sis, record, play-back) of the instrument. | * [[Image:Reports_Tools_Ribbons_380.png]]'''Inputs:''' Opens the channels sources selection. Allows choosing which input or track is monitored. Up to 4 ch at a time. The channel sources can be swapped at any time sis, record, play-back) of the instrument. | ||
Contains the source of the signal to be monitored. | Contains the source of the signal to be monitored. | ||
Line 25: | Line 25: | ||
* '''Source<ref>Using input 5 to input 8 as source with an OR35 analyzer will cause Non-real-time analysis. This way may lose some trigger event samples.</ref>''': input source to be analyzed. It may come from the Front-end input or from the Player in post analysis mode (see the post analysis chapter). In post analysis mode, tracks with a signal bandwidth lower than the range of the Monitor cannot be plugged. | * '''Source<ref>Using input 5 to input 8 as source with an OR35 analyzer will cause Non-real-time analysis. This way may lose some trigger event samples.</ref>''': input source to be analyzed. It may come from the Front-end input or from the Player in post analysis mode (see the post analysis chapter). In post analysis mode, tracks with a signal bandwidth lower than the range of the Monitor cannot be plugged. | ||
===FFT analysis=== | |||
Contains the settings related to the FFT analysis of the signals to be monitored. | Contains the settings related to the FFT analysis of the signals to be monitored. | ||
Line 40: | Line 40: | ||
===Overall analysis=== | |||
[[Image:Waterfall_monitor_02.png|framed|none]] | [[Image:Waterfall_monitor_02.png|framed|none]] | ||
Line 47: | Line 47: | ||
* '''Avg duration''': Each scalar is computed for each block of signal (length of the block is 256/ (''Front-end / Input Sampling''), and then average during the value of the setting. | * '''Avg duration''': Each scalar is computed for each block of signal (length of the block is 256/ (''Front-end / Input Sampling''), and then average during the value of the setting. | ||
* '''Filter order''': the order of the filter: 2, 4, 6, 8 or 10. | * '''Filter order''': the order of the filter: 2, 4, 6, 8 or 10. |