The XPod Bridge conditioner extension module is for strain gauges, dynamic pressure, force and acceleration measurements.
The XPod Bridge conditioner extension module is for strain gauges, dynamic pressure, force and acceleration measurements.


Type: bridge signal conditioning for strain gauges,
*'''Type:''' bridge signal conditioning for strain gage. <br>
Gauge type: Full, Half or Quarter bridge mount. The completion resistors are included in the Xpod,
 
Resistance: Bridge completion resistor: 120 or 350 Ohms for quarter bridge mount.
*'''Gauge type''': Full, Half or Quarter bridge mount. The completion resistors are included in the Xpod.<br>
Gain: Bridge gain: 10 or 100 depending on the required precision and range.
 
Max current: the provided current can be limited to 30 mA up to 4 V and 12 mA up to 10 V.
*'''Resistance''': Bridge completion resistor: 120 or 350 Ohms for quarter bridge mount.<br>
Excitation voltage: Each Xpod provides an excitation voltage from 0 to 10 V.
 
Offset Comp.: Bridge offset comp: Can be used for manual balance of the bridge,
*'''Gain''': Bridge gain: 10 or 100 depending on the required precision and range.<br>
New Transducer Type: This button is available when a transducer type is selected. A new transducer type is necessary when the pre-defined type does not fit the needs. It is used to gather transducers with the same magnitud
 
*'''Max current''': the provided current can be limited to 30 mA up to 4 V and 12 mA up to 10 V.<br>
 
*'''Excitation voltage''': Each Xpod provides an excitation voltage from 0 to 10 V.<br>
 